Home
Products
Engine room fire control room to monitor the water leakage monitoring room Distribution
Engine room fire control room to monitor the water leakage monitoring room Distribution
Engine room fire control room to monitor the water leakage monitoring room Distribution
Fire Monitoring Monitoring objects: room hosts intelligent fire or smoke detectors. Monitoring Implementation: contact signal provided by the manufacturer or install smoke detectors fire by QK-SW101 contact signal acquisition module for acquisition, QK-SW101 module via RS485 interface to access the embedded collection host. Embedded real-time continuous acquisition host polling acquisition will send a message to the monitoring platform for display, alarm. Monitoring performance: real-time display and save intelligent fire host communication protocol provided by the operating parameters can be remotely monitored, each member state and the alarm condition. Monitoring elements: fire alarm state to monitor the status of the district, fire host. The host system detects a signal fire, instant fire protection system status display. . Water leakage monitoring monitored objects: the engine room for precision air leaks around the implementation of monitoring. Monitoring implementation: each region using TTSIM-1A-type positioning possible leak monitoring controller according to the actual needs, select the appropriate leak sensing rope, rope induced leakage air conditioning and access to water around the perimeter, achieve real-time detection of every possible generating the leak. Leak monitoring controller via QK-TS10X conversion module is converted to RS-232 bus connected directly to the control room monitoring host. Monitoring performance: real-time display and recording status leaky cable sensors to leak state, leak location and leak controller electronic map mode. When the air conditioner or leaking pipes along, monitors the main system alarm, and a corresponding icon and text box displays the location of water leakage occurred. Monitoring content: real-time detection and recording changes in water leakage. , The leakage flux lines in the water leakage monitoring system for monitoring the status display as follows in the form of lines and icons. Once leakage occurs, the corresponding location of the line will immediately turn red and display the corresponding text leaking locations. Under normal circumstances, the line is green. . Distribution Monitoring By monitoring all incoming three-phase power distribution cabinet phase voltage, line voltage, current, frequency, power factor, active power, reactive power and other parameters. For important parameters, can be used for recording the curve, system administrators and operators can view historical graphs by day, voltage, frequency, active and reactive power maximum, minimum, current and voltage, current peaks. By analyzing the historical curve parameters, the administrator can clearly know the quality of the power supply is reliable intact, provide a scientific basis for the rational management of the room supply. Monitoring objects: temporarily to monitor the distribution cabinet room. Monitoring Implementation: If the power distribution cabinet instrument comes, through its serial port, a serial bus each circuit distribution cabinet power collection equipment used hand in hand connection pick up the monitor signal is connected to the regional aggregated collection boxes, eventually connected to the embedded data collection terminals. Embedded data acquisition terminal transmits real-time continuous monitoring platform polling collection of information to be displayed, the alarm. If charging meter, you need to install the power meter, then the serial connection. Distribution cabinet comes OF auxiliary contact via QK-SW101 module converts the signal into a dry contact intelligent signal monitoring. Monitoring performance: real-time display and save the value of the monitoring parameters of each distribution cabinet into the line overall. Set the voltage and current upper limit and lower limit, when the monitored voltage or current exceeds the allowable value, the system diagnosed as faulty (alarm) event, monitors the main system alarm. In addition, for each group distribution cabinet switching output current for real-time monitoring display, as adjusted in accordance with load balancing, optimizing distribution operations, to ensure the normal and stable supply of power distribution. Monitoring content: monitor the distribution cabinet output phase voltage, current, frequency, output power (active, reactive, apparent), harmonic ratio, power factor and so on; monitors the output voltage, current, frequency overrun, overload, load unbalanced, AC power failure and other alarms. Monitoring Distribution Cabinet brightest switch the output voltage, current, status.
Contact Detail
Company Name: | Jiang Yue, Energy Technology (Shanghai) Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Yellow Sea() |
Telephone Number: | 021-51877787 |
Company Address: | Room 2238, 555 commercial buildings Guanlin Shanghai Zhongshan South Road, Shanghai, Shanghai, China |
Zip/Postal Code: |
Find More Related Products
- Room precision air conditio..
- Shanghai drilling
- Snap mechanical Certified C..
- Intelligent computer room a..
- Tower of power dedicated bi..
- Central air conditioning un..
- Crown Saver section of how ..
- How to crown Saver Festival
- Energy saving peanut shell ..
- Snap mechanical Certified P..
- Snap _ Large Machinery Larg..
- Chinese electric heating le..
- Jinan a Connaught Technolog..
- Bathroom swipe card reader,..
- Environmental Stick charrin..
- Stick charring machine Guix..
- Snap mechanical drawings, g..
- Continuous bark charring ma..
- Snap mechanical drawing pro..
- Zhumadian peanut shell char..
- Water-saving bathroom swipe..