Home
Products
Room precision air conditioning monitoring UPS monitoring temperature and humidity monitoring
Room precision air conditioning monitoring UPS monitoring temperature and humidity monitoring
Room precision air conditioning monitoring UPS monitoring temperature and humidity monitoring
3. Precision Air Monitoring Monitoring Object: The room precision air conditioning running status monitoring. Monitoring Implementation: Precision Air offers RS232 / 485 communication interface. Divided by the actual situation of the region, the interface connected to the embedded host, embedded host with real-time continuous polling gathering will send a message to the monitoring platform for display, alarm precision air within a region through intelligence. Monitoring performance: Monitor the air conditioner running, with graphics and color change to show the air conditioning, fault alarm. To achieve air-conditioning cooling running state, the high-pressure compressor failure, filter obstruction monitoring and alarms. The monitoring system can be remote monitoring indoor air conditioner control start, stop, and change the setting temperature and humidity. In addition, real-time display and save operating parameters can be remotely monitored each air conditioner communication protocol provided by each member state and the alarm condition. Monitoring content: Analog: return air temperature, return air humidity, return air temperature limit, return air humidity ceiling, return air temperature limit, the lower return air humidity, temperature settings, humidity set point, compressor run time, B diol running time, the percentage of heating, cooling percentage, temperature and humidity changes graph; Digital: air conditioning running, the heater running, cooler running, running a dehumidifier, humidifier running, high pressure alarm compressor, compressed LP alarm, air leakage alarm, temperature and humidity is too high alarm, temperature and humidity low alarm, the humidifier fault alarm, the main fan overload alarm, humidifier water alarm, filter clogging alarm. Control the amount of: air conditioning remote boot and shutdown. Remote setting air-conditioning temperature and humidity. All the monitoring and control of the amount of air conditioning may vary depending on the specific circumstances of air conditioning manufacturers to provide a slight change of protocol. 2.UPS Monitoring Monitoring objects: UPS operating status in real-time monitoring and management. Monitoring and control: UPS provides RS485 communication interface protocol, UPS communication interface via QK-TS10X communication signal converter connected to the embedded data collection terminals. Embedded data collection terminal by bus and UPS communications, UPS acquired various operating data and status information, after the release of data calculated after processing to the external data interface, centralized monitoring platform or monitor client directly read embedded data acquisition terminal Data External data interface, to achieve real-time monitoring on-line UPS. Monitoring performance: real-time display and save operating parameters can be remotely monitored and each member state of each communication protocol provided by UPS. Real-time UPS components determine whether an alarm occurs when a part of UPS failure or the more limited front-end embedded host system alarm or alarm monitoring center host system. Monitoring content: Analog: phase voltage input, the output phase voltage, the bypass phase voltage, phase current input, the output phase current, bypassing the phase current, battery voltage, battery current, output frequency, system load, battery charge level, battery backup time. Digital: the more limited input voltage, output voltage is more limited, more limited output frequency, overload, battery operation, bypass operation mode, battery voltage, battery voltage is low, the system alarm, alarm rectifiers, inverters alarm, system shutdown bypass voltage overrun. 4. Temperature and humidity control monitoring objects: absolute temperature of each area of ??the engine room and relative humidity monitoring. Monitoring Implementation: In the room to the room temperature and humidity monitoring. Temperature and humidity sensor output data, connect to the embedded data acquisition terminal via RS485 communications bus access. Embedded data collection terminal by bus to communicate with temperature and humidity sensors, temperature and humidity to collect operational data and status information, after the release of data calculated after processing to the external data interface, centralized monitoring platform or monitor client directly read embedded data acquisition External data interface data terminal, to achieve real-time monitoring of temperature and humidity online. Monitoring performance: real-time display and record the value of indoor temperature and humidity for each temperature and humidity sensor detected, the display changes in a short period of time graph of electronic map mode. And set the upper limit and lower limit for each temperature and humidity sensor temperature and humidity. When any one of the upper limit of temperature and humidity sensor data exceeds a set or lower limit, monitors the main system alarm. Monitoring content: the real-time temperature and humidity sensor temperature and humidity.
Contact Detail
Company Name: | Jiang Yue, Energy Technology (Shanghai) Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Yellow Sea() |
Telephone Number: | 021-51877787 |
Company Address: | Room 2238, 555 commercial buildings Guanlin Shanghai Zhongshan South Road, Shanghai, Shanghai, China |
Zip/Postal Code: |
Find More Related Products
- Shanghai drilling
- Intelligent computer room a..
- Snap mechanical Certified C..
- Energy saving peanut shell ..
- Tower of power dedicated bi..
- Central air conditioning un..
- Crown Saver section of how ..
- How to crown Saver Festival
- Snap mechanical Certified P..
- Snap _ Large Machinery Larg..
- Environmental Stick charrin..
- Chinese electric heating le..
- Jinan a Connaught Technolog..
- Bathroom swipe card reader,..
- Stick charring machine Guix..
- Snap mechanical drawings, g..
- Continuous bark charring ma..
- Snap mechanical drawing pro..
- Zhumadian peanut shell char..
- Snap mechanical energy-savi..
- Water-saving bathroom swipe..