Car Door relay
Car Door relay
|
Car Door relay performance parameters relay contact form: 1H 1Z Contact voltage drop: Typ: 20mV (10A measured) Max: 250mV (10A measured) Maximum Continuous Current: 60A (23 ℃) (1) (8) Maximum switching current: ON (NO): 150A (2) (8) off (NO): 40A (resistive, 13.5VDC) (8) Maximum switching voltage: See Maximum allowable load range curve minimum load: 1A 6VDC Power Durability: See contact datasheets mechanical durability: 1 × 106 [url = http: //www.zhuangfdq.com] car turn signal control relay [/ url] times 300 times / minute Insulation resistance: 100MΩ (500VDC ) Dielectric strength: between contacts: between 500VAC (3) coil and contact: 500VAC (3) Action time: Maximum: 7ms (at rated voltage measurement) (8) Automotive Relay Release Time: maximum: 5ms ( 4) (8) Ambient temperature: -40 ℃ ~ 125 ℃ car relay vibration: 5Hz ~ 22.3Hz 10mm double amplitude (5) (8) 22.3Hz ~ 500Hz 98m / s2 (5) (8) Automotive Relays impact: 294m / s2 (5) (8) Flame Retardant: meet the UL94-HB or better (in accordance with the requirements of FMVSS 302 standard) (6) terminations way: package fast connection type (QC): Dust car relays weight : about 35g car relay mechanical properties: Housing Retention Force: (tensile and compressive) ≥ 200N leads to foot retention: (tensile and compressive) ≥ 100N leads to foot bending force: (each direction) ≥ 10N (7) Notes: ( 1) measured at 100% rated coil voltage is applied to income; (2) light load peak surge current, 13.5VDC; (3) 1min, leakage current of less than 1mA; (4) from the rated voltage step to 0VDC, and the coil no transient suppression circuit measurement; (5) when energized, normally open contact off time of less than 1ms; (6) FMVSS 302: US Federal Motor Vehicle Safety Standards; (7) test point at 2mm distance leads to the foot end, After removal of the test force, leads to foot deformation should be less than 0.5mm; (8) This parameter is only available in standard coil voltage is 12VDC relay. Coil Rated voltage: 12,24VDC operating voltage (Max.): Operating voltage is 65% of the rated voltage of the release voltage (Min.): Release voltage is the rated voltage 10% of rated coil power: 1.6W, 1.7W, 1.9W } Start the car performance parameters of relay contacts Relay # form: 1H 1Z Contact voltage drop: Typ: 20mV (10A measured) Max: 250mV (10A measured) Maximum Continuous Current: 60A (23 ℃) (1) (8 ) Maximum switching current: ON (NO): 150A (2) [url = http: //www.zhuangfdq.com] T90 to relay [/ url] (8) off (NO): 40A (resistive, 13.5 VDC) (8) Maximum switching voltage: See Maximum allowable load range curve minimum load: 1A 6VDC Power Durability: see contact data sheet mechanical durability: 1 × 106 times 300 times / minute Insulation resistance: 100MΩ (500VDC) Dielectric strength: between contacts: between 500VAC (3) coil and contact: 500VAC (3) Action time: Maximum: 7ms (at rated voltage measurement) (8) Automotive Relay release time: maximum: 5ms (4 ) (8) Ambient temperature: -40 ℃ [url = http: //www.zhuangfdq.com] cold start control relay [/ url] ~ 125 ℃ car relay vibration: 5Hz ~ 22.3Hz 10mm double amplitude (5) ( 8) 22.3Hz ~ 500Hz 98m / s2 (5) (8) Automotive Relays Shock: 294m / s2 (5) (8) [url = http: //www.zhuangfdq.com] battery disconnect device control relay [/ url ] flame: meet the UL94-HB or better (in accordance with the requirements of FMVSS 302 standard) (6) terminations way: package fast connection type (QC): Dust car relay Weight: about 35g car relay mechanical properties : Housing Retention Force: (tensile and compressive) ≥ 200N leads to foot retention: (tensile and compressive) ≥ 100N leads to foot bending force: (each direction) ≥ 10N (7) Notes: (1) applying 100% rated coil measuring the resulting voltage; (2) the lamp load inrush peak currents, 13.5VDC; ([url = http: //www.zhuangfdq.com] car fog relay [/ url] 3) 1min, leakage current less than 1mA; ( 4) from the rated voltage step to 0VDC, and the coil without transient suppression circuit measurement; (5) when energized, normally open contact off time of less than 1ms; (6) FMVSS 302: US Federal Motor Vehicle Safety Standards; (7) test point leads to the foot end of the distance at 2mm, after removal of the test force, leads to foot deformation should be less than 0.5mm; (8) This parameter is only available in standard coil voltage is 12VDC relay. Coil Rated voltage: 12,24VDC operating voltage (Max.): Operating voltage is 65% of the rated voltage of the release voltage (Min.): Release voltage is the rated voltage 10% of rated coil power: 1.6W, 1.7W, 1.9W Car Door relay
Contact Detail
Company Name: | Zhuang Shanghai Electric Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Yep() |
Telephone Number: | 400-0178058 |
Company Address: | Mud town Xincheng Road on the 2nd 3, , Shanghai, China |
Zip/Postal Code: | 200000 |
Find More Related Products
- Automotive PCB relay
- Two-component silicone mold..
- Auto Switch Relay
- Wiper Automotive Relays
- Backrest Automotive Relay #
- Factory direct electric hea..
- Spain ARTECHE relay -ARTECHE
- Relay agent Mitsubishi FX1N..
- Nano-antibacterial PPR pipe..
- ABB Xiamen Electronics Rela..
- Which wedding Chiping offer..
- Electric control valve
- RA4025-D08L solid state rel..
- Guangzhou sea and household..
- Zibo smart home Fingerprint..
- Le expansion PCI to serial ..
- Le expansion Tyrant gold US..
- Lok serial port expansion c..
- Chengdu Yong Chi Japanese s..
- Schneider LC1D50M7C
- New electronic products wit..