Supply 5.0kw electromagnetic induction heater electromagnetic heating controller
Supply 5.0kw electromagnetic induction heater electromagnetic heating controller
The main technical parameters: 1: Dimensions: 219 * 160 * 160 (L * W * H) 2: Operating voltage: 220V 3: Power (adjustable): 3000W-5000W 4: load inductance: 80 ± 10uH 5: Conversion efficiency> 90% 6: Frequency: 20-25kHZ 7: Operating temperature: -10 degrees to +50 degrees 8: Work: continuous heating 9: Langchong protection - + 1500V 10: Anti-clutter: 4000V 11: Induction distance from the heating element coil to the installation of 15-20mm (plus cotton insulation thickness after pressing epoxy board) 12: Multiple sets of coils wound on the same and the heating element, the distance between the coils is greater than 12 cm from each other. 5.0KW control panel wiring instructions 1, three indicators for "Power", "work", "Trouble" light. During normal operation, "Power", "work" in the light. "Fault" lamp. When the hair circuit failure "fault" lights flashing. 2, 220V power supply connected to the "connected to 220V power input," the pillars, regardless of the line of fire just access to the zero line. 3, the coil connected to the "OUT1" "OUT2" of the two terminals, to tighten the screws. 4, the board is set to supply the factory which can work, there is a short route (black) this socket shorted to "switching control" Socket at this time. You can also gently remove the "switching control" short line (black) socket on one end of a two-wire line cord to the "switching control" socket and the other end connected to the two plugs Thermostat The two normally open contacts connected to the test machine. 5.0KW electromagnetic heating control panel instructions and precautions 1, the control cabinet requirements: As the main controller is a high voltage, high current devices, so it should be installed in use in control cabinets, insulated wire through it and heating coil and power supply, temperature controller and other devices connected. To protect the human body does not touch the live parts of electric shock events. Since the controller itself generates heat, so that the control box can be made of air circulation for heat dissipation. 5KW choke element surface due to the need for cooling and the addition of a DC12V DC fan, you can secure the fan on the board of two fixed column, the plug of the fan into the FAN12V two-pin socket next to the relay board . 2, the heating coil requirements: As the Company currently only available in the main control panel to the customer, so this controller must and other accessories such as a heating coil supporting the combination. Use a different controller supporting coil depending on power, the proposed 10-square 5KW insulated high temperature wire wound. Generally circular coil wound on a heated object when the inductance L is 80 ± 10uH (with BICTOR6243 + inductance meter to measure the Victor, and to measure around the barrel. Note: round coil is generally about 23 laps, according to gun Different tube diameters have different number of turns, to grasp in practical use) 3, the heating coil winding: the heating coil according to the specific requirements of users around the system, should ensure that the same core wound heating coil wound to the parameters a home. Keep a distance more than 60mm between the coil and the coil each. 4, the heating coil and the heated metal objects from the requirements: the heating coil surface to be heated metal surface distance depending on the width of the coil should be adjusted. 5KW controller coil to be heated metallic object distance according to diameter should be adjusted with different diameters, the greater the diameter, the closer. The smaller the diameter, the greater the distance. Generally: 15-22mm. If the distance is too small will cause the controller to generate heat due to deterioration of the operating characteristics, and even cause power tube bombing; the distance is too large, power will gradually become smaller, and can not be adjusted, it is counter-voltage protection circuit protection reasons. 5, wiring: The controller can be connected to the electrical power used either by the thermostat normally open contact control use. a, turn on the power to use: the 220V power to the controller line and neutral terminals via insulated wire; coil wire port connected to the coil wire terminal and controller (must be firmly in contact). The board factory setting is the power that is the boot used. b, thermostat control the use of normally open contacts: the 220V power to the controller line and neutral terminals via insulated wire; coil wire port connected to the coil wire terminal and controller (must be firmly in contact) . Gently remove the "switching control" short line (black) socket on one end of a two-wire line cord to the "switching control" socket and the other end connected to the thermostat two plugs often contact, connected to the test machine. Note: The thermostat does not allow contact with the mains or other high-voltage. C, multi-block board line use: When you need to contact by a thermostat control multiple boards simultaneously and stop, first you have to determine as a board motherboard (pick one), and then use the online line (two-wire , two each with a 2-pin plug) to "sub-panel controls" on the system board and another piece of the sub-plate "voltage control" connected, if you want to connect more slave boards, please use the online line are connected to a level above it can be, that is, "deputy board control," a deputy board with another piece of sub-panels "voltage control" connected, so even level to level.
Contact Detail
Company Name: | Dongguan City-Xin Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Liu Xiaodong(Sales Manager) |
Telephone Number: | 0769-13112869869 |
Company Address: | Guangdong Province, Dongguan City in Lam Tsuen, North Station more Chai Ling, Dongguan City, Guangdong, China |
Zip/Postal Code: | 523711 |
Find More Related Products
- 5kw heater electromagnetic ..
- Chi Xin Technology 3.5KW su..
- Supply Chi Xin Technology 5..
- Solar superconducting radia..
- Gas-fired steam generator P..
- The hotel kitchen saving st..
- Botou Container truck speci..
- Distilled liquor dedicated ..
- Steamed rice and noodles sp..
- Kitchen for energy-saving e..
- Beans oar saving gas steam ..
- Supply Nanjing Shijiazhuang..
- Jiangsu Hotel special wall-..
- Production gasifier gasifie..
- 3G Series Marine three screw
- US long-term sales at highe..
- Yao a supply pump energy-sa..
- Mobile shelter prices truck..
- Hotel clubs dedicated wall-..
- Refining equipment Bar
- Wang Yan Wang Yan Zibo Zibo..