Chi Xin Technology 3.5KW supply of electromagnetic heating control panel
Chi Xin Technology 3.5KW supply of electromagnetic heating control panel
First, the technical parameters: Dimensions: 207 * 138 * 115 (L * W * H) 2: Operating voltage: 220V 3: Power (adjustable): 2500W-3500W 4: load inductance: 120 ± 10uH (with a victory card table BICTOR6243 + inductance measurement) 5: Conversion efficiency> 90% 6: Frequency: 20-25kHZ 7: Operating temperature: -10 degrees to +50 degrees 8: Work: continuous heating 9: Langchong protection - + 1500V 10 : Anti-clutter: 4000V 11: induction coil to the mounting distance heating element 15mm (after pressing cotton insulation thickness) 12: Multiple sets of coils and wound on the same heating element coil mutual distance greater than 5 cm. Second, the wiring instructions 1, three LEDs for "Power light", "light work", "fault light" lamp. Normal working hours "power light", "work light" in light. "Fault light" lamp. When the hair circuit failure "fault light" lights flashing. 2, 220V power supply connected to the "AC 220V" column, regardless of the line of fire just access to the zero line. 3, the coil connected to the "ends of the electromagnetic coil connected," the two terminals, to tighten the screws. 4, electromagnetic heating control panel factory setting power which can work, there is a short route (black) this socket shorted to "switching control" Socket at this time. You can also gently remove the "switching control" short line (black) socket on one end of a two-wire line cord to the "switching control" socket and the other end connected to the two plugs Thermostat The two normally open contacts connected to the test machine. Third, use instructions and precautions 1, the control cabinet requirements: As the main controller is high voltage, high current devices, so it should be installed in use in control cabinets, insulated wire through it with the heating coil and power , temperature controllers and other devices to connect. To protect the human body does not touch the live parts of electric shock events. Since the controller itself generates heat, so that the control box can be made of air circulation for heat dissipation. 2, the heating coil: requires 6 square insulated high temperature wire wound. Generally circular coil wound on a heated object when the inductance of 100 ± 10uH (with BICTOR6243 + inductance meter to measure the Victor, and to measure around the barrel. Note: the outer diameter of the circular coil cylinder 100MM generally around 28 laps so, depending on the number of turns different barrel diameter, to grasp in practical use) 3, the heating coil winding: the heating coil in accordance with the specific requirements of users around the system, should ensure that the same core wound heating coil winding to a set of parameters. Keep a distance more than 50mm between the coil and the coil each. 4, the heating coil and the heated metal objects from the requirements: the heating coil surface to be heated metal surface distance depending on the width of the coil should be adjusted. 3.5KW control panel coil to be heated metallic object distance according to diameter should be adjusted with different diameters, the greater the diameter, the closer. The smaller the diameter, the greater the distance. Generally: 15-22mm. If the distance is too small will cause the control panel and fever due to deterioration of the operating characteristics, and even cause power tube bombing; the distance is too large, power will gradually become smaller, and can not be adjusted, it is counter-voltage protection circuit protection reasons. 5, wiring: The controller can be connected to the electrical power use, it can also be controlled by a thermostat normally closed contact. a, turn on the power to use: the 220V power to the controller line and neutral terminals via insulated wire; coil wire port connected to the coil wire terminal and controller (must be firmly in contact). The board factory setting is the power that is the boot used. b, thermostat control the use of normally open contacts: the 220V power to the controller line and neutral terminals via insulated wire; coil wire port connected to the coil wire terminal and controller (must be firmly in contact) . Gently remove the "switching control" short line (black) socket on one end of a two-wire line cord to the "switching control" socket and the other end connected to the thermostat two plugs often contact, connected to the test machine. Note: The thermostat does not allow contact with the mains or other high-voltage. C, multi-block electromagnetic heating control panel for online use: when required by a thermostat control multiple contact electromagnetic heating control panel while working at the same time stop, first you have to determine an electromagnetic heating control board as a board (pick one) and then line line (two-wire, two each with a 2-pin plug) to "sub-panel controls" on the system board and another piece of the sub-plate "voltage control" connected, if you want to connect more slave boards use Online line are connected to a level above that of a "sub-panel control," Deputy board with another piece of sub-panels "voltage control" connected, so even level to level. "Integrity and pragmatic, refinement and innovation" as our company's purpose. We offer reasonable prices, strict compliance with the terms of the agreement contract, won the users rely on and praise. Here, we sincerely thank all the support and love our customers friends. Solemnly promise: We will be more efforts to provide better products and better services for new and old customers, and customers to create a better tomorrow!
Contact Detail
Company Name: | Dongguan City-Xin Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Liu Xiaodong(Sales Manager) |
Telephone Number: | 0769-13112869869 |
Company Address: | Guangdong Province, Dongguan City in Lam Tsuen, North Station more Chai Ling, Dongguan City, Guangdong, China |
Zip/Postal Code: | 523711 |
Find More Related Products
- Supply Chi Xin Technology 5..
- Solar superconducting radia..
- Gas-fired steam generator P..
- The hotel kitchen saving st..
- Distilled liquor dedicated ..
- Steamed rice and noodles sp..
- Yao a supply pump energy-sa..
- Botou Container truck speci..
- Mobile shelter prices truck..
- Kitchen for energy-saving e..
- Beans oar saving gas steam ..
- Supply Nanjing Shijiazhuang..
- Jiangsu Hotel special wall-..
- Production gasifier gasifie..
- Supply Jiangsu special disc..
- 3G Series Marine three screw
- G30-1 single-screw pump I-I..
- US long-term sales at highe..
- Hotel clubs dedicated wall-..
- Refining equipment Bar
- Wang Yan Wang Yan Zibo Zibo..