Home
Products
5kw heater electromagnetic heating supply electromagnetic induction heater electromagnetic heating control panel ..
5kw heater electromagnetic heating supply electromagnetic induction heater electromagnetic heating control panel ..
5kw heater electromagnetic heating supply electromagnetic induction heater electromagnetic heating control panel ..
First, the electromagnetic heating control panel technical parameters: Dimensions: 219 * 160 * 160 (L * W * H) 2: Operating voltage: 220V 3: Power (adjustable): 3500W-5000W 4: load inductance: 65 ± 5uH 5: Conversion efficiency> 90% 6: Frequency: 20-25kHZ 7: Operating temperature: -10 degrees to +50 degrees 8: Work: continuous heating 9: Langchong protection - + 1500V 10: Anti-clutter: 4000V 11: induction coil to the mounting distance heating element 15-20mm (after pressing cotton insulation thickness) 12: Multiple sets of coils and wound on the same heating element coil mutual distance greater than 12 cm. Second, the electromagnetic heating control panel wiring instructions 1, three indicators for "Power", "work", "Trouble" light. During normal operation, "Power", "work" in the light. "Fault" lamp. When the hair circuit failure "fault" lights flashing. 2, 220V power supply connected to the "connected to 220V power input," the pillars, regardless of the line of fire just access to the zero line. 3, the coil connected to the "OUT1" "OUT2" of the two terminals, to tighten the screws. 4, the electromagnetic heating control panel factory setting power which can work, there is a short route (black) this socket shorted to "switching control" Socket at this time. You can also gently remove the "switching control" short line (black) socket on one end of a two-wire line cord to the "switching control" socket and the other end connected to the two plugs Thermostat The two normally open contacts connected to the test machine. Third, use instructions and precautions 1, the control cabinet requirements: As the main controller is high voltage, high current devices, so it should be installed in use in control cabinets, insulated wire through it with the heating coil and power , temperature controllers and other devices to connect. To protect the human body does not touch the live parts of electric shock events. Since the controller itself generates heat, so that the control box can be made of air circulation for heat dissipation. 2, the heating coil: requires 6 square insulated high temperature wire wound. Generally circular coil wound on a heated object when the inductance of 100 ± 10uH (with BICTOR6243 + inductance meter to measure the Victor, and to measure around the barrel. Note: the outer diameter of the circular coil cylinder 100MM generally around 28 laps so, depending on the number of turns different barrel diameter, to grasp in practical use) 3, the heating coil winding: the heating coil in accordance with the specific requirements of users around the system, should ensure that the same core wound heating coil winding to a set of parameters. Keep a distance more than 50mm between the coil and the coil each. 4, the heating coil and the heated metal objects from the requirements: the heating coil surface to be heated metal surface distance depending on the width of the coil should be adjusted. 3.5KW control panel coil to be heated metallic object distance according to diameter should be adjusted with different diameters, the greater the diameter, the closer. The smaller the diameter, the greater the distance. Generally: 15-22mm. If the distance is too small will cause the control panel and fever due to deterioration of the operating characteristics, and even cause power tube bombing; the distance is too large, power will gradually become smaller, and can not be adjusted, it is counter-voltage protection circuit protection reasons. "Integrity and pragmatic, refinement and innovation" as our company's purpose. We offer reasonable prices, strict compliance with the terms of the agreement contract, won the users rely on and praise. Here, we sincerely thank all the support and love our customers friends. Solemnly promise: We will be more efforts to provide better products and better services for new and old customers, and customers to create a better tomorrow!
Contact Detail
Company Name: | Dongguan City-Xin Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Liu Xiaodong(Sales Manager) |
Telephone Number: | 0769-13112869869 |
Company Address: | Guangdong Province, Dongguan City in Lam Tsuen, North Station more Chai Ling, Dongguan City, Guangdong, China |
Zip/Postal Code: | 523711 |
Find More Related Products
- Chi Xin Technology 3.5KW su..
- Supply Chi Xin Technology 5..
- Solar superconducting radia..
- Gas-fired steam generator P..
- The hotel kitchen saving st..
- Distilled liquor dedicated ..
- Botou Container truck speci..
- Mobile shelter prices truck..
- Steamed rice and noodles sp..
- Kitchen for energy-saving e..
- Beans oar saving gas steam ..
- Supply Nanjing Shijiazhuang..
- Jiangsu Hotel special wall-..
- Production gasifier gasifie..
- 3G Series Marine three screw
- G30-1 single-screw pump I-I..
- US long-term sales at highe..
- Yao a supply pump energy-sa..
- Hotel clubs dedicated wall-..
- Refining equipment Bar
- Wang Yan Wang Yan Zibo Zibo..