Siemens 6SE6440 inverter common alarm faults: F0001 overcurrent F0002 DC link overvoltage F0003 DC bus undervoltage F0012 F0022-temperature radiator power component failure F0054 I / O board failure than is the easiest Siemens 6se6440 / 430/420 converter failure, which have in common a few series inverter, fault alarm can refer to each other. Representative overcurrent F0001, overcurrent can be reset and can not be divided into two kinds of reset. Can be reset, it may be too large load transient, sensor fault detection current and other causes. You can not reset the general power components have been damaged. F0002, F0003, respectively, a DC bus overvoltage and undervoltage, the alarm time can be measured at the input AC voltage and p + / n- DC side (usually 380v / ac ac = 560v / dc), if these two places voltage is normal It is generally a fault detection circuit, need repair. F0012 is a temperature over-temperature, high-power inverter for cooling and fans have a very high demand, there will be fan failure alarm temperature detection circuit seldom fail. F0022 is a more serious fault. Out of this fault cautious restart, output short circuit is generally possible, IGBT power module is damaged or drive out of trouble, need repair. F0054 is the I / O board alarm. The actual maintenance I / O board rarely damaged. Small power connection pins may be bad, powerful copy again what procedures the board, general can solve the problem. Here does not describe, more fault alarm information, please go to the county maintenance experience controlled company website. Guangzhou gun control, professional maintenance of Siemens 6SE6440 / 430/420 series, 6SE70 series inverter device, 6RA70 / 6RA28 / 6RA24 Series DC converter, reasonable fees, service speed fast, high-power field site service. 1. For foreign customers, the company may send engineers on-site testing, maintenance, please contact the specific telephone. 2. freight or courier service over the device, the user prior to shipment shooting equipment model and serial number. Gun control company maintenance completed, will be running with load video capture (in the video shoot, (will also record the model number and serial number), to facilitate customer acceptance service model series:. MM440 inverter single phase 208V- -240V no built-in filter "Description: 6SE6440 (model) -2UC (no built-in filter) 11 (can drive motor power) -2AA1" 6SE6440-2UC11-2AA1 /0.12kw 6SE6440-2UC12-5AA1 /0.25kw 6SE6440-2UC13- 7AA1 / 0.37kw 6SE6440-2UC15-5AA1 / 0.55kw 6SE6440-2UC17-5AA1 / 0.75kw 6SE6440-2UC21-1BA1 /1.1kw 6SE6440-2UC21-5BA1 /1.5kw 6SE6440-2UC22-2BA1 / 2.2kw 6SE6440-2UC23-0CA1 / 3kw MM440 Inverter three-phase 380V - 480V without built-in filter 6SE6440-2UD13-7AA1 /0.37kw 6SE6440-2UD15-5AA1 /0.55kw 6SE6440-2UD17-5AA1 /0.75kw 6SE6440-2UD21-1AA1 /1.1kw 6SE6440-2UD21 -5AA1 /1.5kw 6SE6440-2UD22-2BA1 / 2.2kw 6SE6440-2UD23-0BA1 / 3kw 6SE6440-2UD24-0BA1 / 4kw 6SE6440-2UD25-5CA1 /5.5kw 6SE6440-2UD27-5CA1 /7.5kw 6SE6440-2UD31-1CA1 / 11kw 6SE6440-2UD31-5DB1 / 15kw 6SE6440-2UD31-8DB1 / 18.5kw 6SE6440-2UD32-2DB1 / 22kw 6SE6440-2UD33-0EB1 / 30kw 6SE6440-2UD33-7EB1 / 37kw 6SE6440-2UD34-5FB1 / 45kw 6SE6440-2UD35-5FB1 / 55kw 6SE6440-2UD37-5FA1 / 75kw 6SE6440-2UD38-8FB1 / 90kw 6SE6440-2UD41-1FA1 / 110kw 6SE6440-2UD41-3GA1 / 132kw 6SE6440-2UD41-6GA1 / 160kw 6SE6440-2UD42-0GA1 / 200kw MM430 models of three-phase inverter 380V- -480V no built-in filter 6SE6430-2UD27-5CA0 / 7.5kw 6SE6430-2UD31-1CA0 / 11kw 6SE6430-2UD31-5CA0 / 15kw 6SE6430-2UD31-8DA0 /18.5kw 6SE6430-2UD32-2DA0 / 22kw 6SE6430-2UD33-0DA0 / 30kw 6SE6430-2UD33-7EA0 / 37kw 6SE6430-2UD34-5EA0 / 45kw 6SE6430-2UD35-5FA0 / 55kw 6SE6430-2UD37-5FA0 / 75kw 6SE6430-2UD38-8FA0 / 90kw 6SE6430-2UD41-1FA0 / 110kw 6SE6430-2UD41-3FA0 / 132kw 6SE6430 -2UD41-6GA0 / 160kw 6SE6430-2UD42-0GA0 / 200kw 6SE6430-2UD42-5GA0 / 250kw MM420 inverter single-phase 208--240V no internal filter 6SE6420-2UC11-2AA1 / 0.12kw 6SE6420-2UC12-5AA1 /0.25kw 6SE6420-2UC13-7AA1 /0.37kw 6SE6420-2UC15-5AA1 /0.55kw 6SE6420-2UC17-5AA1 /0.75kw 6SE6420-2UC21-1BA1 /1.1kw 6SE6420-2UC21-5BA1 /1.5kw 6SE6420-2UC22-2BA1 /2.2kw 6SE6420- 2UC23-0CA1 / 3kw MM420 inverter three-phase / 380--480V no internal filter 6SE6420-2UD13-7AA1 / 0.37kw 6SE6420-2UD15-5AA1 /0.55kw 6SE6420-2UD17-5AA1 /0.75kw 6SE6420-2UD21-1AA1 / 1.1kw 6SE6420-2UD21-5AA1 /1.5kw 6SE6420-2UD22-2BA1 /2.2kw 6SE6420-2UD23-0BA1 / 3kw 6SE6420-2UD24-0BA1 / 4kw 6SE6420-2UD25-5CA1 /5.5kw 6SE6420-2UD27-5CA1 /7.5kw 6SE6420- 2UD31-1CA1 / 11kw MM410 inverter single-phase / 208--240V no internal filter Fits motor 6SE6410-2UB11-2AA0 / 0.12kw 6SE6410-2UB12-5AA0 /0.25kw 6SE6410-2UB13-7AA0 /0.37kw 6SE6410 -2UB15-5BA0 /0.55kw 6SE6410-2UB17-5BA0 /0.75ke=w MM440 inverter-type single-phase 208V - 240V with integrated filter "" Description: 6SE6440 (model) -2UC (with built-in filter) 11 (can drive Motor Power) -2AA1 "6SE6440-2AB11-2AA1 /0.12kw 6SE6440-2AB12-5AA1 /0.25kw 6SE6440-2AB13-7AA1 /0.37kw 6SE6440-2AB15-5AA1 /0.55kw 6SE6440-2AB17-5AA1 /0.75kw 6SE6440-2AB21- 1BA1 /1.1kw 6SE6440-2AB21-5BA1 /1.5kw MM440 Inverter three-phase 380V - 480V with built-in filter 6SE6440-2AD22-2BA1 2.2 6SE6440-2AD23-0BA1 3 6SE6440-2AD24-0BA1 4 6SE6440-2AD25-5CA1 5.5 6SE6440-2AD27-5CA1 7.5 6SE6440-2AD31-1CA1 11 6SE6440-2AD31-5DA1 15 6SE6440-2AD31-8DA1 18.5 6SE6440-2AD32-2DA1 22 6SE6440-2AD33-0EA1 30 6SE6440-2AD33-7EA1 37 6SE6440-2AD34-5FA1 45 6SE6440- 2AD35-5FA1 55 6SE6440-2AD37-5FA1 75 MM430 models of three-phase inverter 380V - 480V with built-in filter 6SE6430-2AD27-5CB0 7.5 6SE6430-2AD31-1CB0 11 6SE6430-2AD31-5CB0 15 6SE6430-2AD31-8DB0 18.5 6SE6430- 2AD32-2DB0 22 6SE6430-2AD33-0DB0 30 6SE6430-2AD33-7EB0 37 6SE6430-2AD34-5EB0 45 6SE6430-2AD35-5FB0 55 6SE6430-2AD37-5FA0 75 6SE6430-2AD38-8FA0 90 MM420 inverter single-phase 208--240V Fits with integrated filter Motor Power KW 6SE6420-2AB11-2AA1 0.12 6SE6420-2AB12-5AA1 0.25 6SE6420-2AB13-7AA1 0.37 6SE6420-2AB15-5AA1 0.55 6SE6420-2AB17-5AA1 0.75 6SE6420-2AB21-1BA1 1.1 6SE6420-2AB21 -5BA1 1.5 MM420 380--480V three-phase inverter with integrated filter 6SE6420-2AD22-2BA1 2.2 6SE6420-2AD23-0BA1 3 6SE6420-2AD24-0BA1 4 6SE6420-2AD25-5CA1 5.5 6SE6420-2AD27-5CA1 7.5 6SE6420-2AD31 -1CA1 11 
Contact Detail
Company Name: Guangzhou county controlled automatic control Technolog..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang(Maintenance Manager)
Telephone Number: 020-22938756
Company Address: Great downtown Long Lin Road Panyu District No. 18 (near the Jiangxi section) Xin'an Business Center 433, , Guangdong, China
Zip/Postal Code: 511400
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450