Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

EJA130A high static pressure transmitter

EJA130A high static pressure transmitter
EJA130A high static pressure transmitter
EJA130A high static pressure transmitter

Larger photo of automa dispenser

Company:Xi'an cloud Instrument Instrument Co., Ltd.
Information Name: EJA130A high static pressure transmitter
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
EJA130A high static pressure transmitter EJA130A high static pressure transmitter M bellows H diaphragm measuring range -100 ~ 100kPa (-400 ~ 400inH2O) -500 ~ 500kPa (-2000 ~ 2000inH2O) measurement range 1 ~ 100kPa (4 ~ 400inH2O) 5 ~ 500kPa (20 ~ 2000inH2O) accuracy of ± 0.065% ± 0.065% Protection class IP67, NEMA 4X, and JIS C0920 immersion-proof anti-specification FM, CENELEC ATEX, CSA, IECEx output signal 4 ~ 20mA DC or FOUNDATION fieldbus or PROFIBUS PA two-wire digital communication power BRAIN and HART:? 10.5 ~ 42V DC (intrinsically safe: 10.5 ~ 30V DC) Fieldbus: 9 ~ 32V DC (Intrinsically Safe Entity model 9 ~ 24V DC, intrinsically safe FISCO model 9 ~ 17.5V DC) Ambient temperature -40 ~ 85 ℃ (-40 ~ 185 ℉) (Normal) -30 ~ 80 ℃ (-22 ~ 176 ℉) (built-in indicator) Process Temperature -40 ~ 120 ℃ (-40 ~ 248 ℉) (ordinary) maximum working pressure 32MPa (4500psi) install 2-inch pipe installation wetted parts materials Diaphragm SUS316L (Diaphragm: Hastelloy C-276) accommodating chamber housing aluminum flange SUS316 alloy or SUS316 stainless steel (optional) Selection Table Basic Specifications Code: EJA130A-DMS5A-92NN Item 1: output signal -D 4-20mA DC / BRAIN protocol digital communication -E 4-20mA DC / HART protocol digital communication -F FF Fieldbus Communication Item 2: Measuring range (diaphragm) M 1-100KPa H 5-500KPa Chapter 3: wetted parts materials S SUS316 SUS316L SUS316 Item 4: process interface 0 No process connector (Rc1 / 4 internal thread On the container chamber flange) 1 Rc1 / 4 internal thread process connection 2 Rc1 / 2 female thread process connection 3 1 / 4NPT threaded process connection 4 1 / 2NPT threaded process connector without process connector 5 (1 / 4NPT internal thread ) Item 5 on the container chamber flange: Bolts and nuts material A JIS SCM435 32MPa B JIS SUS630 32MPa C JIS SUH660 32MPa Chapter 6: Installation -2 vertical pipe connecting the right pressure, the upper part of the installation process vertical pipe connecting joints -3 the right pressure, the lower part of the installation process vertical pipe connecting joints -6, left the high pressure, the upper part of the installation process connections -7 vertical pipe connecting the left pressure, the lower part of the installation process pipe connecting joints 8 level, the right of the high-pressure pipe connection - 9, left high pressure Item 7: Electrical connection 0 G1 / 2 internal thread, an electrical interface 2 1 / 2NPT internal thread, two electrical connections without blind plug within 3 Pg13.5 thread, two electrical connections without blind plug within 4 M20 thread , two electrical interface, without blind plugs 5 G1 / 2 internal thread, two electrical interface, a blind plug 7 1 / 2NPT internal thread, two electrical interface, an internal 8 Pg13.5 blind threaded plug, two electrical interface A blind plug within 9 M20 thread, two electrical interface, a blind plug Section 8: Built-D digital display digital display table Table E with measuring range display table setting button N for section 9: A mounting bracket JIS SECC flat bracket B JIS SUS304 flat bracket C JIS SECC L-bracket D JIS SUS304 L-bracket N no three, additional functions Item 1: flameproof / intrinsically safe explosion does not specify NF1 NEPSI license: dⅡCT6 ambient temperature: -40-60 ℃ Electrical Interface: 1 / 2NPT FF1 FM Explosion license C1: ⅠⅡ & Ⅲ Div 1 & 2, Gps.B, C, D, E, F & G NEMA 4X Temperature: C1: T6 FF15 FM Explosion license C1 : ⅠⅡ & Ⅲ Div 1 & 2, Gps.B, C, D, E, F & G NEMA 4X Temperature: C1: T6 KF1 CENELEC (KEMA) explosion license: EExd Ⅱ CT4, T5, T6 KF5 CENELEC (KEMA) explosion license: EExd Ⅱ CT4, T5, T6 CF1 CSA Explosion license C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G ENCL: Type4X Temperature: CI: T4, T5, T6 CF15 CSA Explosion license C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G ENCL: Type4X Temperature: CI: T4, T5, T6 NS1 NEPSI intrinsically safe approval: ia Ⅱ CT4 ambient temperature: -40-60 ℃ Electrical Interface: 1 / 2NPT FS1 FM intrinsically safe approval Intrinsically C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G non-flammable C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F & G KS1 CENELEC (KEMA) intrinsically safe approval: EEx ia Ⅱ CT4 CS1 CSA intrinsically safe approval: C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, A, B, C, D, E, F & G ENCL: Type4X temperature C1: T4 FU1 contain FF1 and FS1 KU1 It contains KF1.KS1 KEMA N-type and N-type EX nA ⅡCT4 CU1 contains CF1 and CS1 SU1 SAA flameproof and intrinsically safe and non-sparking Ex dⅡCT6 / T5 / T4 IP67, Ex ia ⅡCT4 IP67, Ex nⅡ CT4 IP67 KS5 CENELEC (KEMA) Intrinsically safe: [Entity Mode]: EEx ia Ⅱ CT4; [Fisco Mode]: EEx ia Ⅱ CT4 / EEx ia Ⅱ BT4 Item 2: flameproof sealing joints not specify G71 connection ports: 1 / 2NPT applicable cable diameter : Φ8.5 ± 0.5 (1 个) G72 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (1 个) G81 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (2) G82 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (2 个) Item 3: painting: color change or change of paint color changes do not specify P1 only applies to transmitters housing Munsell Flag Code: N1.5, P2 black color change applies only to the transmitter housing Munsell Flag Code: 7.5BG4 / 1.5 green P7 color change applies only to the transmitter housing painted metallic silver X1 Changes epoxy paint baked Section 4: A lightning protection does not specify a transmitter power supply voltage: 10.5-32V DC (intrinsically safe: 10.5-30V DC) Maximum allowable current: 6000A (1X4μS), repeatedly 1000A (1X40μS) 100 sequence 5: Oil-prohibited or forbidden water, cut oil processing is not designated K1 K2 Degreasing degreasing cleaning treatment process and the film cartridge filling fluorine oil, -20-80 ℃ K5 Degreasing temperature and drying K6 degreased and washed and dried membrane cartridge filling fluorine oil, temperature -20-80 ℃ Chapter 6: Correction Unit does not specify D1 P correction (Psi unit) D3 bar calibration (bar unit) D4 M calibration (kgf / cm2) Item 7: sealed SUS630 not specify Y fastening nut accommodating chamber flange bolts and nuts are coated SUS630 (liquid silicone rubber) Item 8: Long vent plug is not specified U Overall Length: 112mm (standard: 32mm) first 9: fast response time is not specified refresh F1: ≤0.125 seconds response time (including the minimum damping time constant): up to 0.3-0.5 seconds (L diaphragm 0.6 seconds) Item 10: PID / LM function does not specify the LC1 PID control function, Link Master function Item 11: CPU abnormal output is set low is not specified, C1 low side: ≤-5% (3.2mA DC) Item 12: NAMUK NE43 not specify C2 [output signal 3.8 ~ 20.5mA] failure Alarm output -5%, 3.2mA or less C3 [output signal 3.8 ~ 20.5mA] fault alarm output to 110%, more than 13 21.6mA item: stainless steel amplifier housing is not specified E1 Amplifier Case Material: SCS14A stainless steel (equivalent to SUS316L stainless steel or cast ASTM CF-8M) Item 14: Gold-plated diaphragm seal diaphragm gilt A1 is not specified in item 15: R1 user configuration does not specify the configuration software Item 16: accommodating chamber flange unspecified N1 without exhaust drain Cypriot N2 N1 and without process connection, both sides of the processing volume chamber flange DIN 19213 7/16 inch × 20 internal thread (mounting thread), rear side with blind plugs N3 N1, N2 volume chamber flange, diaphragm, body and Blind plug accessories manufacturers Item 17: stainless steel tag is not specified N4 JIS SUS304 stainless steel tag plate fixed to the transducer's first 18: Parts Manufacturing prove not specify M01 M11 flange accommodating chamber accommodating chamber flange process connections Item 19: Stress test pressure leak test to prove you do not specify T09 M, H diaphragm test pressure: 32MPa test fluid: nitrogen residence time of 10 minutes More information: http: //www.ybfmc.com 
Contact Detail
Company Name: Xi'an cloud Instrument Instrument Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang Nan()
Telephone Number: 029-88623812
Company Address: Xi'an, Xi'an, Shaanxi Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450