Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

EJA210220 flange mounted differential pressure transmitter

EJA210220 flange mounted differential pressure transmitter
EJA210220 flange mounted differential pressure transmitter
EJA210220 flange mounted differential pressure transmitter

Larger photo of automa dispenser

Company:Xi'an cloud Instrument Instrument Co., Ltd.
Information Name: EJA210220 flange mounted differential pressure transmitter
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
EJA210 / 220 flange mounted differential pressure transmitter EJA210A / EJA220A flange mounted differential pressure transmitter M bellows H diaphragm measuring range -100 ~ 100kPa (-400 ~ 400inH2O) -500 ~ 500kPa (-2000 ~ 2000inH2O) measurement range 1 ~ 100kPa (4 ~ 400inH2O) 5 ~ 500kPa (20 ~ 2000inH2O) Accuracy ± 0.2% ± 0.2% Protection class IP67, NEMA 4X, and JIS C0920 immersion-proof anti-specification FM, CENELEC ATEX, CSA, IECEx 4 ~ 20mA DC output signal or FOUNDATION fieldbus or PROFIBUS PA two-wire digital communication power BRAIN and HART:? 10.5 ~ 42V DC (intrinsically safe: 10.5 ~ 30V DC) Fieldbus: 9 ~ 32V DC (Intrinsically Safe Entity model 9 ~ 24V DC, intrinsically safe FISCO model 9 ~ 17.5V DC) Ambient temperature -40 ~ 85 ℃ (-40 ~ 185 ℉) (Normal) -30 ~ 80 ℃ (-22 ~ 176 ℉) (built-in indicator) Process temperature -40 ~ 120 ℃ (-40 ~ 248 ℉) (ordinary) maximum working pressure rated pressure flange mounting flange mounting flange dimensions EJA210A: 3-inch (80mm), 2-inch (50mm) EJA220A: 4 -inch (100mm), 3-inch (80mm) diaphragm material (high pressure side) SUS316L, Hastelloy C-276, tantalum flange material S25C, SUS304, SUS316 SUS316 stainless steel or aluminum housing (optional) Selection Table Basic Specifications Code: EJA220A-DMSJ12G5A-92NN Item 1: output signal -D 4-20mA DC / BRAIN protocol digital communication -E 4-20mA DC / HART protocol digital communication -F FF Fieldbus Communication Item 2: Measuring range (diaphragm) M 1-100KPa H 5-500KPa Chapter 3: high pressure side (flange side) wetted S JIS paragraph 4 SUS316L JIS SUS316 JIS SUS316 W Hastelloy C-276 JIS SUS316 JIS SUS316: flange Specifications J1 JIS 10K J2 JIS 20K A1 ANSI150 A2 ANSI300 P1 JPI150 P2 JPI300 D2 DIN PN10 / 16 D4 DIN PN25 / 40 G2 GB PN10 / 16 G4 GB PN25 / 40 Chapter 5: membrane protrusion length (X2) 2 X2 = 50mm 4 X2 = 100mm X2 = 150mm Item 6 6: flange size / material G 100mm (4 ") / JIS S25C H 100mm (4") / JIS SUS304 J 100mm (4 ") / JIS SUS316 D 80mm (3") / JIS S25C E 80mm (3 ") / JIS SUS304 F 80mm (3") / JIS SUS316 Item 7: Low-side process interface 0 No process connector (Rc1 / 4 internal thread on the container chamber flange) 1 Rc1 / 4 internal threaded process connection 2 Rc1 / 2 female thread process connection 3 1 / 4NPT threaded process connection 4 1 / 2NPT threaded process connector without process connector 5 (1 / 4NPT internal threads on the container chamber flange) Item 8: Bolts and nut material A JIS SCM435 B JIS SUS630 C JIS SUH660 Article 9: Installation 9 in the pipe connecting the left high-pressure section 10: Electrical connection 0 G1 / 2 internal thread, an electrical interface to 2 1 / 2NPT internal thread, two electrical interface, without blind plugs within 3 Pg13.5 thread, two electrical connections without blind plug 4 M20 threaded, two electrical connections without blind plug 5 G1 / 2 internal thread, two electrical interface, a blind plug 7 1 / 2NPT internal thread, two electrical interface, a blind plug within 8 Pg13.5 thread, two electrical interface, a blind plug within 9 M20 thread, two electrical interface, a blind plug Item 11: Built-in display table D E digital display digital display table strap Measuring range knob N for section 12: - N N has been three additional functions Item 1: flameproof, intrinsically safe explosion does not specify NF1 NEPSI license: dⅡCT6 ambient temperature : -40-60 ℃ Electrical Interface: 1 / 2NPT FF1 FM Explosion license C1: ⅠⅡ & Ⅲ Div 1 & 2, Gps.B, C, D, E, F & G NEMA 4X Temperature: C1: T6 FF15 FM Explosion license C1: ⅠⅡ & Ⅲ Div 1 & 2, Gps.B, C, D, E, F & G NEMA 4X Temperature: C1: T6 KF1 CENELEC (KEMA) explosion license: EExd Ⅱ CT4, T5, T6 KF5 CENELEC (KEMA) explosion license: EExd Ⅱ CT4, T5, T6 CF1 CSA Explosion license C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G ENCL: Type4X Temperature: CI: T4, T5, T6 CF15 CSA Explosion license C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps , B, C, D, E, F, & G ENCL: Type4X Temperature: CI: T4, T5, T6 NS1 NEPSI intrinsically safe approval: ia Ⅱ CT4 ambient temperature: -40-60 ℃ Electrical Interface: 1 / 2NPT FS1 FM present Ann license Intrinsically C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G non-flammable C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F & G KS1 CENELEC (KEMA) intrinsically safe approval: EEx ia Ⅱ CT4 CS1 CSA intrinsically safe approval: C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, A, B, C, D, E, F & G ENCL: Type4X temperature C1: T4 FU1 contain FF1 and FS1 KU1 contain KF1. KS1 KEMA N-type and N-type EX nA ⅡCT4 CU1 contains CF1 and CS1 SU1 SAA flameproof and intrinsically safe and non-sparking Ex dⅡCT6 / T5 / T4 IP67, Ex ia ⅡCT4 IP67, Ex nⅡ CT4 IP67 KS5 CENELEC (KEMA) intrinsically safe : [Entity Mode]: EEx ia Ⅱ CT4; [Fisco Mode]: EEx ia Ⅱ CT4 / EEx ia Ⅱ BT4 Item 2: flameproof sealing joints not specify G71 connection ports: 1 / 2NPT Applicable cable diameter: Φ8. 5 ± 0.5 (1 个) G72 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (1 个) G81 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (2 个) G82 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (2 个) Item 3: painting: color change or change of paint color does not specify P1 change applies only to the transmitter housing Mongolia Sergio Flag Code: N1.5, P2 black color change applies only to the transmitter housing Munsell Flag Code: 7.5BG4 / 1.5 green P7 color change applies only to the transmitter housing X1 painted metallic silver ring changes epoxy baked Item 4: A lightning protection does not specify the transmitter power voltage: 10.5-32V DC (intrinsically safe: 10.5-30V DC) Maximum allowable current: 6000A (1X4μS), repeatedly 1000A (1X40μS) 100 sequence 5 Item: Oil-prohibited or forbidden water, cut oil processing is not designated K1 K2 Degreasing degreasing cleaning treatment process and the film cartridge filling fluorine oil, -20-80 ℃ K5 Degreasing temperature and drying K6 Degreasing and drying the film cartridge filling fluorine oil, temperature -20-80 ℃ Item 6: Correction Unit does not specify D1 P correction (Psi unit) D3 bar calibration (bar unit) D4 M calibration (kgf / cm2) Item 7 : sealed SUS630 not specify Y fastening nut accommodating chamber flange bolts and nuts SUS630 coated (liquid silicone rubber) Item 8: No you do not specify Q serrated flange sealing surface without serrated processing (ANSI flange only ) Article 9: Teflon (PTFE) film is not specified T FEP Teflon membrane, filling fluorine oil, the working range 20-120 ℃, 0-2MPa (Not available for vacuum) Item 10: CPU abnormal output is set to the low side or NAMUK NE43 not specify C1 low side: ≤-5% (3.2mA DC) C2 (NAMUK NE43) [output signal 3.8 ~ 20.5mA] fault alarm output -5%, 3.2mA or less C3 (NAMUK NE43) [output signal 3.8 ~ 20.5mA] fault alarm output to 110%, more than 11 21.6mA item: stainless steel amplifier housing is not specified E1 Amplifier Case Material: SCS14A stainless steel (equivalent to SUS316L cast stainless steel or ASTM CF-8M) first 12: Gold-plated diaphragm seal diaphragm does not specify A1 gilded Item 13: Rapid response does not specify F1 refresh time: ≤0.125 seconds response time (including the minimum damping time constant): up to 0.5 seconds Chapter 14: PID / LM function LC1 PID control function is not specified, Link function Item 15: Stainless steel tag plate N4 JIS SUS304 stainless steel is not specified tag is fixed to the transmitter's first 16: Parts Manufacturing prove not specify M03 H: side flange, the diaphragm seat L: container chamber flange M13 H: side flange, the diaphragm seat L: volume chamber flange process connections Item 17: Stress Test / drain pressure test to prove you do not specify T31 JIS 10K test pressure: 2MPa test liquid nitrogen residence time of 10 minute T32 JIS 20K test pressure: 5MPa test fluid nitrogen residence time of 10 minutes T36 ANSI / JPI 150 Tests Stress: 3MPa test liquid nitrogen residence time of 10 minutes T37 ANSI / JPI 300 Test pressure: 7.7MPa test liquid nitrogen residence time of 10 minutes More information : http: //www.ybfmc.com 
Contact Detail
Company Name: Xi'an cloud Instrument Instrument Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang Nan()
Telephone Number: 029-88623812
Company Address: Xi'an, Xi'an, Shaanxi Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450