Pressure Transmitter EJA430A Product Summary: EJA430A series using silicon resonant sensor technology. Monocrystalline silicon pressure or temperature changes for the absence of hysteresis, is ideal material. Silicon resonant sensor overvoltage, temperature changes and static pressure influence reduced to a minimum, providing unparalleled long-term stability. A, EJA430A pressure transmitter technical parameters EJA430A A diaphragm pressure transducer B bellows measuring range -0.1 ~ 3MPa (-15 ~ 430psi) -0.1 ~ 14MPa (-15 ~ 2000psi) measurement range 0.03 ~ 3MPa (4.3 ~ 430psi) 0.14 ~ 14MPa (20 ~ 2000psi) accuracy of ± 0.065% ± 0.065% Protection class IP67, NEMA 4X, and JIS C0920 immersion-proof anti-specification FM, CENELEC ATEX, CSA, IECEx output signal 4 ~ 20mA DC or FOUNDATION? site bus or PROFIBUS PA two-wire digital communication power BRAIN and HART: 10.5 ~ 42V DC (intrinsically safe: 10.5 ~ 30V DC) Fieldbus: 9 ~ 32V DC (Intrinsically Safe Entity model 9 ~ 24V DC, intrinsically safe FISCO model 9 ~ 17.5V DC) Ambient temperature -40 ~ 85 ℃ (-40 ~ 185 ℉) (Normal) -30 ~ 80 ℃ (-22 ~ 176 ℉) (built-in indicator) Process temperature -40 ~ 120 ℃ (-40 ~ 248 ℉) (ordinary) Maximum overpressure 4.5MPa (645psig) 21MPa (3000psig) install 2-inch pipe installation wetted parts materials Diaphragm SUS316L (Diaphragm: Hastelloy C-276), Hastelloy C- 276, tantalum, Monel volume chamber flange SUS316, Hastelloy C-276, Monel, aluminum alloy or SUS316 stainless steel housing (optional) Second, EJA430A pressure transmitter selection parameters Basic Specifications Code: EJA430A-DAS5A- 92NN Item 1: output signal -D 4-20mA DC / with digital communication (BRAIN protocol) -E 4-20mA DC / with digital communication (HART protocol) -F FF fieldbus communication Item 2: Measuring range (diaphragm ) A 0.03-3MPa B 0.14-14MPa Chapter 3: wetted material S JIS SCS14A JIS SUS316L JIS SUS316 H JIS SCS14A Hastelloy C-276 JIS SUS316 M JIS SCS14A Monel JIS SUS316 T JIS SCS14A tantalum JIS SUS316 A Ha s alloy C-276 Hastelloy C-276 Hastelloy C-276 D Tantalum Hastelloy C-276 Hastelloy C-276 B Monel Belmondo Belmondo is Cornell Item 4: process interface 0 No process connector (RC1 / 4 female on the container chamber flange) 1 RC1 / 4 threaded process connection 2 RC1 / 2 internal thread Process connections 3 1 / 4NPT threaded process connection 4 1 / 2NPT threaded process connector without process connector 5 (1 / 4NPT female) Item 5 on the volume chamber flange: Bolts and nuts material A JIS SCM435 3MPa 14MPa B JIS SUS630 3MPa 14MPa C JIS SUH660 3MPa 14MPa item 6: Installation -2 vertical pipe connecting the right pressure, the upper mounting Process connections -3 vertical pipe connecting the right pressure, the lower part of the installation process vertical pipe connecting joints -6, left high pressure, the upper part of the installation process connections -7 vertical pipe connecting the left pressure, the lower part of the installation process connector 8 level in the pipe connecting the right high pressure - 9 horizontal pipe connection, left high pressure Item 7: Electrical connection 0 G1 / 2 internal thread an electrical interface 2 1 / 2NPT internal thread two electrical connections without blind plug thread within 3 Pg13.5 two electrical connections without blind plug 4 M20 threaded within two electrical connections without blind plug 5 G1 / 2 internal thread two electrical connections, blind plug a 7 1 / 2NPT internal thread two electrical interfaces, one blind plug 8 Pg13.5 thread two electrical connections Blind 9 M20 threaded plug a two electrical connections, blind plug one of the first eight: Built-D digital display table display table digital display E strap Measuring range knob N for section 9: Mounting bracket A JIS SECC 2 "; pipe installation (Pinto Type) B JIS SUS304 2"; pipe installation (Pinto Type) C JIS SECC 2 "; tube mounting (L-type) D JIS SUS304 2"; tube mounting (L-type) N no three, Additional functions Item 1: flameproof, intrinsically safe explosion does not specify NF1 NEPSI license: dⅡCT6 ambient temperature: -40-60 ℃ Electrical Interface: 1 / 2NPT FF1 FM Explosion license C1: ⅠⅡ & Ⅲ Div 1 & 2, Gps.B , C, D, E, F & G NEMA 4X Temperature: C1: T6 FF15 FM Explosion license C1: ⅠⅡ & Ⅲ Div 1 & 2, Gps.B, C, D, E, F & G NEMA 4X Temperature: C1: T6 KF1 CENELEC (KEMA) Explosion License: EExd Ⅱ CT4, T5, T6 KF5 CENELEC (KEMA) explosion license: EExd Ⅱ CT4, T5, T6 CF1 CSA Explosion license C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G ENCL : Type4X Temperature: CI: T4, T5, T6 CF15 CSA Explosion license C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G ENCL: Type4X Temperature: CI: T4, T5, T6 NS1 NEPSI intrinsically safe approval: ia Ⅱ CT4 ambient temperature: -40-60 ℃ Electrical Interface: 1 / 2NPT FS1 FM intrinsically safe approval Intrinsically C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F, & G noncombustible of C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, B, C, D, E, F & G KS1 CENELEC (KEMA) intrinsically safe approval: EEx ia Ⅱ CT4 CS1 CSA intrinsically safe approval: C1: ⅠⅡ & Ⅲ Div, 1 & 2, Gps, A, B , C, D, E, F & G ENCL: Type4X temperature C1: T4 FU1 contain FF1 and FS1 KU1 CF1 and CS1 SU1 SAA flameproof and intrinsically safe and non-sparking Ex contains KF1.KS1 KEMA N-type and N-type EX nA ⅡCT4 CU1 contain dⅡCT6 / T5 / T4 IP67, Ex ia ⅡCT4 IP67, Ex nⅡ CT4 IP67 KS5 CENELEC (KEMA) Intrinsically Safe: [Entity Mode]: EEx ia Ⅱ CT4; [Fisco Mode]: EEx ia Ⅱ CT4 / EEx ia Ⅱ BT4 first 2: flameproof seal joints G71 is not specified, the connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (1 个) G72 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 ( 1) G81 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (2 个) G82 connection ports: 1 / 2NPT Applicable cable diameter: Φ8.5 ± 0.5 (2 个) Item 3 : Painting: color change or change paint color does not specify P1 change applies only to the transmitter housing Munsell Flag Code: N1.5, P2 black color change applies only to the transmitter housing Munsell Flag Code : 7.5BG4 / 1.5 green P7 color change applies only to the transmitter housing X1 painted metallic silver epoxy paint change Item 4: A lightning protection does not specify a transmitter power supply voltage: 10.5-32V DC (intrinsically safe Type: 10.5-30V DC) Maximum allowable current: 6000A (1X4μS), repeatedly 1000A (1X40μS) 100 sequence 5: Oil-prohibited or forbidden water, cut oil processing is not designated K1 K2 Degreasing degreasing cleaning treatment process and the film cartridge filling fluorine oil, -20-80 ℃ K5 Degreasing temperature and drying washing and drying process K6 skimmed filling bellows fluorine oil, temperature, paragraph 6 -20-80 ℃: Correction Unit does not specify D1 P correction (Psi unit) D3 bar calibration (bar unit) D4 M calibration (kgf / cm2) Section 7: SUS630 nuts sealed container chamber does not specify Y fastening flange bolts and nuts are coated SUS630 (liquid silicone rubber) Item 8: Long vent plug is not specified U Overall Length: 112mm (standard: 32mm) Item 9: NAMUK NE43 (1) does not specify C3 (NAMUK NE43) [output signal 3.8 ~ 20.5mA] fault alarm output 110% 21.6mA above Item 10: NAMUK NE43 (2) does not specify C2 (NAMUK NE43) [output signal 3.8 ~ 20.5mA] -5% fault alarm output, item 11 3.2mA the following: CPU exception when output is set to the low side C1 does not specify the low side: ≤-5% (3.2mA DC) Item 12: Stainless steel amplifier housing is not specified E1 Amplifier Case Material: SCS14A stainless steel (equivalent to SUS316L cast stainless steel or ASTM CF-8M) Item 13: Rapid response is not F1 specified refresh time: ≤0.125 seconds response time (including the minimum damping time constant): up to 0.3 seconds Chapter 14: PID / LM function does not specify the LC1 PID control function, Link Master function Item 15: R1 configuration does not specify a user Item 16 configuration software: gold diaphragm seal diaphragm does not specify A1 gilded Item 17: accommodating chamber flange unspecified N1 without exhaust drain plugs N2 N1 and without process connection, both sides of the container chamber flange Processing DIN 19213 7/16 inch × 20 internal thread (mounting thread), rear side with blind plugs N3 N1, N2 volume chamber flange, diaphragm, body and parts manufacturing certification blind plug Item 18: stainless steel tag is not Specifies N4 JIS SUS304 stainless steel tag plate is fixed on the transmitter's first 19: Parts Manufacturing prove not specify M01 M11 flange accommodating chamber accommodating chamber flange, item 20 Process connection: Pressure test leak pressure test to prove you do not specify T03 A Diaphragm Pressure Test: 3MPa test fluid nitrogen residence time of 10 minutes T02 B Diaphragm Pressure Test: 14MPa test fluid: nitrogen residence time of 10 minutes More information: http: //www.ybfmc.com 
Contact Detail
Company Name: Xi'an cloud Instrument Instrument Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang Nan()
Telephone Number: 029-88623812
Company Address: Xi'an, Xi'an, Shaanxi Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450