With the benefits of digital bridge
With the benefits of digital bridge
To use the same benefits digital bridge 1. First power-IEC power cord with one end connected to the bridge on the left rear of the IEC socket and the other end into a suitable power outlet, move the bridge left rear rocker switch, even if the bridge is energized. When energized, the display range and the function indicator lights up along. Bridge can be automatically placed inductance, capacitance measurement files, and 1KHz frequency parallel equivalent status. Under normal circumstances, an internal circuit for a few seconds after the power-stable, can be measured. 2. Access method tested components ⑴ generally radial leaded components can be directly inserted into the combination test folder plywood, while access to special flexible lead elements should help the plywood clutch, the clutch means is located directly below the test folder. ⑵ access when axial leaded components, in order to avoid kinking lead, can be axially adapter, first two parts are inserted into the ends of the test folder, and then the spacing element is adjusted to fit the measured position, then Axial lead component insertion parts put across the folder. ⑶ axial adapter required quite strong given the occasion, such as in the measurement of a large number of similar elements, requires the use of the support plate. Installing the support plate: First, the axial adapter adjusted to the appropriate location, and the support plate mount adapter head to the axial direction, so that each axial adapter through the slot seam support plate, place a support plate the fixing screw holes aligned electrical bridge board, and finally tighten the screws. Note: When installing difficult to tighten the screws. Note: This bridge, although capable of charging capacitor access test for protection, but preferably should be duly charged capacitor discharge resistor after the measurement. 3. Note the use of the reading and display ⑴ instrument measuring conditions 6 show effective display is not necessarily all in some measure to measure the value of data is not likely to beat the larger end, beating these values ??should be rounded down, read its stable value. (2) general use automatic range measurement, in order to ensure selection to the correct range, the operation to the manual mode can observe the actual operating range. When applied to the same batch of the same kind of measuring cell batch test, you can select the range lock mode. (3) Series - Parallel indicating selective although the bridge has a display equivalent values ??in series or parallel, but the Q value under adverse circumstances, using the above two methods are impossible to obtain basic accuracy. When you need to change a display in order to improve the basic accuracy of the bridge is the series by the subscript s, the subscript p means the parallel. (4) Frequency prompt 200μF ~ 2000μF capacitors, 200H ~ 2000H inductance measurement frequency can only get basic accuracy 100Hz. Similarly, capacitors and inductors 200μH ~ 2mH 200pF ~ 2nF only at 1KHz measurement frequency in order to obtain the basic accuracy, thus obtaining optimal test performance, you should select the most appropriate test frequency. (5) Test level shows a high K ceramic capacitors or high permeability magnetic inductors, etc., are more sensitive to the size of the test signal level, a different test level will produce distinct measurements. At the same time, the lower the test level, measurement stability worse. With the benefits of digital bridge Wholesale Price Come http://www.szbangya.com/bangya-SonList-1123282/ consulting with the benefits of digital bridge Store more product information all in http://www.chem17.com/st219628
Contact Detail
Company Name: | Nanjing Environmental Protection Equipment Co., Ltd. to |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Xiaohu() |
Telephone Number: | 025-57055542 |
Company Address: | Nanjing, Nanjing, Jiangsu Province, China |
Zip/Postal Code: |
Find More Related Products
- Digital bridge manufacturers
- Instek digital bridge
- Landfill special eco-bags
- Chengdu eco-bags
- Eco bag | eco bag manufactu..
- Hydrothermal synthesis reac..
- Fiberglass septic price shi..
- CJF autoclave
- Multipoint magnetic stirrer
- Simple autoclave
- Electromagnetic pulse valve..
- Airshower
- Sludge Treatment Project
- New energy drying sludge fi..
- Hengshui preferential glare..
- Energy-efficient snowmaking..
- Shanghai two horizontal mou..
- Shanghai visual filter back..
- Shanghai pilot valve type g..
- How to apply condition bagh..
- Characteristics of PPS dust..