Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Factory direct differential pressure controller switch - dual chamber with side

Factory direct differential pressure controller switch - dual chamber with side
Factory direct differential pressure controller switch - dual chamber with side
Factory direct differential pressure controller switch - dual chamber with side

Larger photo of automa dispenser

Company:Yichang with Shun Industrial Co., Ltd.
Information Name: Factory direct differential pressure controller switch - dual chamber with side
Update Time:2014-10-23
Validity:180
Specifications:TS-CK
Quantity:1108.00
Price Description: RMB/
Inquire Now
Yichang with Shun Industrial Co., Ltd. is a pressure switch instrumentation and automation, instrumentation, accessories and other products processing and manufacturing of professional manufacturers, the main products series; pressure controller (pressure switch), pressure gauge, differential pressure controller (differential pressure switch), differential pressure gauge, high static differential pressure gauge, differential pressure control table, level meter, smart meters, flow meters, pressure gauge, explosion-proof switch, corrosion meter switch. Products are divided into mechanical, electronic two categories, products controlled physical parameters involved in high multiple species, low pressure, micro-pressure, negative pressure, temperature, flow, level, etc., its form is divided into ordinary, corrosion, waterproof, dustproof, explosion-proof, high temperature, high pressure and so on. The company's products are widely used in metallurgy, chemical industry, petroleum, iron and steel, machinery, refrigeration equipment, refrigeration equipment, pump pressure control, pressure control low water level protection, power plants, cement, food, shipbuilding and other industries gas, steam and water, oil other liquid pressure equipment and other industrial equipment to the actuator supporting pressure monitoring, alarm, interlock protection, to achieve two automatic control. This product also can be water pressure controller for the fire protection system hydraulic pressure controller with rain, process pressure control switch, gas pressure controller, boiler pressure controller (pressure switch), the pump pressure switch, air press pressure switch, pressure switch for a compressor, a hydraulic lubricating apparatus controlling pressure. Suitable medium: water, gas, oil, lubricants, refrigerants and other neutral and corrosive type media. The company's products with high precision pressure control, stable performance, high vibration resistance, corrosion resistance and good. Product sophisticated structure, reasonable shape, versatility, cost-effective. Integrity, strength and quality of products along with the IPC has been recognized by industry professionals, departments. Welcome friends to visit, guidance and business negotiation. TS-CK Series Differential Pressure Controller (Pressure Switch) TSEx-CK-proof differential pressure series controller (pressure switch) ◆ Use: The instrument is widely used in metallurgy, chemical industry, petroleum, iron and steel, machinery, refrigeration equipment, refrigeration equipment , pump differential pressure control, differential pressure control low-level protection, environmental protection and water recycling differential pressure control, differential pressure control chamber, flat oil furnace differential pressure control, power plants, cement, food, shipbuilding and other industries of gas, steam and water, oil the liquid pressure equipment and other industrial equipment supporting the implementing agencies, pressure monitoring, alarm, interlock protection, to achieve two automatic control. Suitable medium: water, gas, oil, lubricants, refrigerants and other neutral and corrosive type media. This product has a pressure control of high precision, stable performance, high vibration resistance, corrosion resistance and good. Particularly suitable for installation on both ends of the upper and lower interface-intensive, large-medium viscosity and high temperature applications. ◆ Main technical indicators: □ Working medium viscosity: <1 × 10-3m2 / s; □ Ambient temperature: -20 ~ + 80 ℃; □ medium temperature: Normal 0 ~ + 85 ℃; temperature 0 ~ + 300 ℃; □ site Table indication accuracy: ± 2.5% FS; □ Vibration resistance: Switching difference not adjustable max2m / s2; adjustable switching difference max4m / s2; □ Repeatability: ≤4MPa ± 1.0% FS;> 4MPa ± 1.5% FS; □ Case protection performance: IP65, metal aluminum case; □ Pressure Connection interface: G: internal thread M12 × 1.25; Z: brass or stainless steel fittings links φ6 tube through the conversion; M: external thread M20 × 1.5 with internal thread ZG1 / 4 "a total of one; R: user-defined; □ switch contact capacity (max): 1,380VAC 6A; 2,220VAC 3A; 3,220VDC 3A; 4,24VDC 2A; □ electrical wire interface: M16 × 1.5 dense blockade Protective tight joints; □ switch contact form: Figure 1; work as pressure increases C-NO-pass, pressure drop C-NC-pass; □ proof mark: ExedПCT6, e increased safety, d is flameproof; ◆ adjustment Instructions: a main channel hydraulic system working pressure 1.6MPa, working pressure side piping 1.5MPa, require the main channel and lateral pipeline pressure difference is less than 0.1MPa alarm, the medium is oil, the choice of a TS-CKD3DAZ type switch difference not adjustable (only one adjustment screw) controller, the lower value is set to switch 0.1MPa to meet the requirements, the specific adjustment method as follows: ("-" or "LP" mark) interface respectively with two-phase pressure calibrator connection. 2, loosen the lock nut, will be charged gas, liquid introduction controller pressure sensing chamber. 4, the high side and low side of the controller while the input normal operating pressure. 5, keep the pressure side of the pressure constant, the the low-pressure side pressure drops 1.5MPa (this value can be read from standard pressure gauge) or less, the switching operation of the contacts 6, the pressure increased to the low pressure side at 1.5MPa (this value can be read from standard pressure gauge), and adjusting screw counterclockwise rotation to align the ruler near the main pointer 0.1MPa, until the differential pressure switch contacts in action at 0.1MPa (about 0.12MPa reset). 7, tighten the lock nut, repeatedly adjusting the differential value greater than 0.1MPa action until the switching point to meet the requirements so far Note: 1, there is only one adjustment screw controller means setting adjustment range can be adjusted, but the difference is not adjustable switching hysteresis contact the factory has been set up. 2, differential pressure controller has two adjustment screws for switching difference adjustable setpoint adjustment lever above the same adjustment method, switching differential adjustment screw is used to adjust the size of the hysteresis with adjustable pressure adjustment method with the same 3, double switch differential pressure controllers are two adjustment screws action setpoint adjustment screw to adjust the pressure the same way as the double switch. ◆ Commissioning notes: · selection of the differential pressure controller, the setting value is located in the middle of the best part of the controller setpoint adjustment range is generally between 20% to 80%. · Controller cover open before, you should cut off the power. Open the controller cover, do not screw rotating inside or fiddle with the internal parts. ? When commissioning pressure do not exceed the maximum allowable pressure. · Instrument controllers should be under conditions common technical performance requirements, the shock and the sharp pulsating pressure on the lower side and reliable installation and correct readings and other non-affected environments. · Installation diversification, wall mounted, tubes can work properly. If installed in an outdoor environment, they should be given adequate protection. From ambient temperature to the drastic changes, direct sunlight radiation, corrosive gas or water infiltration. · Meter installation (or removal) must use the tool holder is strictly prohibited by hand or with a tool collision dial toggle arm to prevent changes in performance. · When connecting piping medium, high and low entry can not be reversed, otherwise the contact does not operate. Interface with a "+" or "HP" logo for high voltage interface, with a "-" or "LP" logo interface for low-voltage interface. ? When the sensor interface is internally threaded pipe joints screwed into the sensor depth of not more than 12mm. ? When installing the pressure port, should clamp controller hex joints interfaces, preventing the switch housing and the high-low pressure joints loosening affect controller performance. · When installing the cable, you should select the appropriate cable diameter, clamping nut and tighten the cable into place, so as not to loose cable and prevent the infiltration of water or dust. · On-off current can not be greater than the rated value. Cable wire into the internal terminal board should be deep enough, and tighten the fastening screw terminal board. · The controller must be professional maintenance, should be replaced after the rubber gasket aging. · For the peak pressure and the controlled pressure pulses of liquid medium, a pressure shock damper installed on the interface controller, in order to eliminate adverse effects. (To be specified when ordering, I can plant matching supply). · Medium temperature is too high (over 85 ℃), you can add a spiral condenser (to be specified when ordering, I can plant matching supply) before the pressure port. This instrument can be optional "flange + capillary" type protectors, see F-type structure size preservative pressure controller. · The explosion controller shell, external to want reliable, contact capacity shall not exceed the rated value. · Explosion-proof differential pressure controller is suitable for a variety of flammable media ⅡCT6 above (see GB3836.1) 1 area following dangerous places. · The controller set value on the switch value, minimum value is lower switching position (adjustable switching difference) the user can adjust itself. · If you have special selection and installation, please provide the product name, specifications, environmental conditions, media name and physical state, the process connection and process connection, installation, and related accessories and other special technical requirements. ◆ Outline: 1, TS-CKB differential pressure controller front, side dimensions (left); TS-CKD differential pressure controller front, side dimensions (right): 2, TS-CKS differential pressure controller front, side dimensions (left); TS-CK-type differential pressure controller back dimension drawing (right) ◆ Pressure connection diagram: Yichang with Shun Industrial Co., Ltd. is a pressure switch instrumentation and automation, instrumentation, accessories and other products processing and manufacturing of professional manufacturers, Production of major products series; pressure controller (pressure switch), pressure gauge, differential pressure controller (pressure switch), differential pressure gauge, high static differential pressure gauge, differential pressure control table, level meter, smart meter , flow meter, pressure gauge, explosion-proof switch, corrosion meter switch. Products are divided into mechanical, electronic two categories, products controlled physical parameters involved in high multiple species, low pressure, micro-pressure, negative pressure, temperature, flow, level, etc., its form is divided into ordinary, corrosion, waterproof, dustproof, explosion-proof, high temperature, high pressure and so on. The company's products are widely used in metallurgy, chemical industry, petroleum, iron and steel, machinery, refrigeration equipment, refrigeration equipment, pump pressure control, pressure control low water level protection, power plants, cement, food, shipbuilding and other industries gas, steam and water, oil other liquid pressure equipment and other industrial equipment to the actuator supporting pressure monitoring, alarm, interlock protection, to achieve two automatic control. This product also can be water pressure controller for the fire protection system hydraulic pressure controller with rain, process pressure control switch, gas pressure controller, boiler pressure controller (pressure switch), the pump pressure switch, air press pressure switch, pressure switch for a compressor, a hydraulic lubricating apparatus controlling pressure. Suitable medium: water, gas, oil, lubricants, refrigerants and other neutral and corrosive type media. The company's products with high precision pressure control, stable performance, high vibration resistance, corrosion resistance and good. Product sophisticated structure, reasonable shape, versatility, cost-effective. Integrity, strength and quality of products along with the IPC has been recognized by industry professionals, departments. Welcome friends to visit, guidance and business negotiation.
Contact Detail
Company Name: Yichang with Shun Industrial Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Yang Ming School()
Telephone Number: 07176525876
Company Address: The 6th East Village Road, Yichang City, Hubei, China