Fluke106 enables Palm OS, without workplace limit
Fluke106 enables Palm OS, without workplace limit
Fluke106 price Fluke106 manufacturers Fluke106 offer Fluke106 image Fluke106 price Fluke106 manufacturers Fluke106 offer Fluke106 image Fluke 106 handheld digital multimeter Fluke 106 digital multimeter designed to meet your needs and design work! This digital multimeter has been specially designed to achieve the Palm OS, without workplace limit. Accuracy within one year after calibration applies an operating temperature of 18 ° C to 28 ° C, relative humidity of 0-75%. Accuracy specifications of the form: ± ([% of reading] + [least significant digits]) Accuracy Specifications Function Range Resolution Accuracy AC voltage 1 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 1.0% + 3 dc voltage 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 0.5% + 3 AC mV 600.0 mV 0.1 mV 3.0% + 3 Diode Test 2 2.000 V 0.001 V 10% resistance? (ohm) 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 capacitance 3 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 frequency of 4 Hz (10 Hz - 100 kHz)?? 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA duty cycle 4 1-99% 0.10% NA alternating current (40 Hz - 200 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5% + 3 DC Current 4.000 A 10.00 A 0.001 A 0.01 A 1.5% + 3 1. All AC current, frequency and duty cycle are specified in the 1% to 100% range. Not specified range of input values ??lower than 1%. 2. In general, the open circuit test voltage of 2.0 V, a short circuit current of <0.6 mA. 3. The parameter does not include the error due to test lead capacitance and capacitance caused by the substrate (in the 50 nF range may be up to 1.5 nF). 4. All AC current, frequency and duty cycle are specified in the 1% to 100% range. Not specified range of input values ??lower than 1%. Function Overload Protection Input Impedance (nominal) Common Mode Rejection Ratio normal mode rejection ratio AC voltage 600 V1> 10 MΩ <100 pF2 in DC current, 50 Hz or 60 Hz, the greater than 60 dB? AC mV 600 mV> 1M , <100 pF at 50 Hz or at 60 Hz, greater than 80 dB? DC voltage 600 V1> 10 MΩ <100 pF in DC current, 50 Hz or 60 Hz, the more than 100 dB at 50? Hz or 60? Hz, the greater than 60? dB 1. Maximum 6 x 105 V Hz 2. For medium voltage (AC), the input impedance is about 1 MΩ. General Specifications for the highest voltage between any Terminal and Earth Ground 600 V Display (LCD) 6000 counts, updated three times per battery type two AAA batteries (NEDA 24A, IEC LR03) battery life of at least 200 hours Temperature Operation When non-condensing 10 ° C and 30 ° C at 0 ° C to 40 ° C Storage temperature -30 ° C to 60 ° C Relative Humidity Operating humidity is below 10 ° C ≤ 90%;? 30 ° C at 40 ° C to ? ≤ 75% Operating humidity, 40 MΩ Range: 10 ° C @ 30 ° C to ≤ 80%; 30 ° C at 40 ° C to ≤ 70% Altitude Operating Storage altitude 2000 m above sea 12000 m temperature coefficient 0.1 X (?? specified accuracy) / ° C (<18 ° C or> 28 ° C) current input fuse protection 11A, 1000V fast-blow, you must use the Fluke specified parts Dimensions (H x W x D) 142 mm x 69 mm x 28mm Weight 200 g Degree of protection IEC 60529: IP 40 safety IEC 61010-1: 600 V CAT III, pollution degree 2 Electromagnetic Environment IEC 61326-1: Portable electromagnetic compatibility applies only in South Korea. ? A Class A equipment (industrial broadcasting and communications equipment) 1. This product meets the requirements of industrial (A Class) electromagnetic devices, the purchaser or user should be aware of this. The device is suitable for the working environment, rather than a family environment. Multimeters FLUKE101 CHINA FLUKE101 KIT CHINA multimeter multimeter Multimeter FLUKE107 CHINA FLUKE106 CHINA
Contact Detail
Company Name: | Shenzhen City on September Instrument Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Kim Chui(Sales Staff) |
Telephone Number: | 0755-82509203 |
Company Address: | Silver Spring Garden District Longhua Minzhi 8 105, Shenzhen City, Guangdong, China |
Zip/Postal Code: | 518131 |
Find More Related Products
- Fluke18B + Digital Multimet..
- Where can I do Yuan blue an..
- Nursery Substrate sale, Bo-..
- Large spot YHS-302A process..
- Ninety-nine equipment for s..
- On-line particle counter
- Shapingba Korean training |..
- Ninety-nine equipment for s..
- Ninety-nine instrument Dire..
- MS6460
- MS6812 National Direct
- MAS830L
- The new MS7287 process cali..
- New Products MS7226 Multifu..
- The new MS7224 multifunctio..
- NINE-718D; YHS-718D calibra..
- New Agilent U1242B handheld..
- New high precision digital ..
- Handheld U1233A True RMS di..
- U1232A handheld digital mul..
- Shenzhen Agilent U1194A han..