Large spot YHS-302A process calibrator multimeter
Large spot YHS-302A process calibrator multimeter
Shenzhen large spot YHS302A process calibrator multimeter, YHS302A authentic guarantee, YHS302A Ram New YHS-302A process calibrator, YHS-302A process calibrator multimeter, YHS-302A process calibrator multimeter instrument ninety-nine, YHS-302A Shenzhen City on September Instrument Co., Ltd. Multimeter YHS-302A-type process is a set of digital multimeter and signal source function in one of the high-precision, high-resolution, highly reliable integrated digital hand-held instrument calibration, the output signal can be displayed simultaneously value and the measured signal value, with LED backlight for use in dimly lit places. Instrument AC-DC power supply can be more convenient to use. Instrument signal output and measurement functions are primarily designed for the implementation of on-site verification for the industrial automation field instrument maintenance needs. The instrument also has a multimeter function, is a field instrument engineering, computer distributed control system maintains an ideal tool for personnel, instrument fitter. It is different from common electrician multimeters and signal sources, is the instrument workers multimeter. The instrument has two channels, big-screen dual display - The upper display output, the lower display measurements. While the output side can be measured simultaneously displayed simultaneously. Realization of a machine. 24V power output meter separately. Instrument uses large-capacity rechargeable Ni-MH battery (with charger), with the common market, user-friendly replacement. Output: Current: 0 ~ 24.00mA accuracy: 0.1% Voltage: 0 ~ 100.00mV, 0 ~ 10.00V, accuracy: 0.1% Frequency: 1Hz-1.00kHz, 10.00Hz ~ 10.00kHz measurement functions: DC voltage: 0 ~ 700V AC and DC current: 0 ~ 4.000mA, 0 ~ 400.0mA resistance: 0 ~ 40.00MΩ capacitance: 0 ~ 200.0μF frequency: 0 ~ 5.000MHz diode drop triode amplification thermocouple temperature measurement functions 3.1 General 3.1.1 Output two-port 30V overload protection. 3.1.2 Auto range. 3.1.3 Full range overload protection. 3.1.4 measure between the ends of the earth and the maximum allowable voltage: 1000V DC or AC (rms) 3.1.5 Working height: Max 2000m 3.1.6 Display: LCD, while the display output and measurement data. 3.1.7 Maximum display value: 3999 digits. -6- 3.1.8 Polarity indication: automatic indication, '-' indicates negative polarity. 3.1.9 Overrange display: '0L' or '-0L'. 3.1.10 Sampling time: about 0.4 seconds / second. 3.1.11 unit display: functional, power units. 3.1.12 resettable fuse Specifications: 500mA / 250V 3.1.13 Power supply: 1.2V × 4 AA batteries, capacity 1800mAH. 3.1.14 Battery voltage indication: LCD display symbols. 3.1.15 Temperature coefficient: less than 0.1 × accuracy / ℃ 3.1.16 Operating temperature: -10 ℃ ~ 40 ℃ 3.1.17 Storage temperature: -20 ℃ ~ 50 ℃ 3.1.18 Size: 195 × 92 × 55mm 3.1.19 Weight: about 600g (including battery) 3.2 Technical Specifications Ambient temperature: 23 5 ℃ Relative humidity: 200kHz for reference 1) measuring range: 0 ~ 5MHz 2) Input frequency amplitude: at 0 ~ 100kHz, the magnitude is greater than 500mV. In 100kHz ~ 5MHz, the magnitude is greater than 3V. 3) Input frequency amplitude is not greater than 10V. 4) Overload Protection: 250V DC or AC (rms) -10 3.2.8 CONTINUITY TEST Range function If the measured line resistance is less than 40, the buzzer will sound meter included. - Open circuit voltage of about 0.5V - Overload Protection: 250V DC or AC (rms) 3.2.9 Diode Test Range Resolution Function 1mV Display approximate value of diode forward voltage - forward current of about 1mA - reverse DC voltage of about 1.5V - Overload protection: 250V DC or AC (rms) 3.2.10 Transistor hFE: 0 ~ 4000 - overload: Fast-Acting Fuse 500mA / 250V. - 3.2.11 Temperature measurement: K-type thermocouple (optional). - Overload protection: Fast-Acting Fuse 500mA / 250V. 3.2.12 DC voltage signal output: Range Resolution Accuracy 10V 10mV ± (0.1% of reading + 5 characters) 100mV 100μV 3.2.13 DC voltage signal output: Range Resolution Accuracy 22mA 10μA ± (0.1% of reading + 5 words) - load capacity: 0 ~ 800Ω (20mA or less up to 1kΩ or more). -11- 3.2.14 frequency signal output: Range Resolution Accuracy 1 ~ 100Hz 0.01Hz ± 0.1Hz 100Hz ~ 1kHz 0.1Hz ± 0.5 Hz 1 ~ 10kHz 1Hz ± 5 Hz - square wave, 50% duty cycle, the amplitude of 4V . 3.2.15 24V DC voltage output voltage accuracy load capacity 24V 2% 30mA
Contact Detail
Company Name: | Shenzhen City on September Instrument Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Kim Chui(Sales Staff) |
Telephone Number: | 0755-82509203 |
Company Address: | Silver Spring Garden District Longhua Minzhi 8 105, Shenzhen City, Guangdong, China |
Zip/Postal Code: | 518131 |
Find More Related Products
- Nursery Substrate sale, Bo-..
- Ninety-nine equipment for s..
- Ninety-nine equipment for s..
- Ninety-nine instrument Dire..
- MS6460
- MS6812 National Direct
- Shapingba Korean training |..
- MAS830L
- The new MS7287 process cali..
- New Products MS7226 Multifu..
- The new MS7224 multifunctio..
- NINE-718D; YHS-718D calibra..
- New Agilent U1242B handheld..
- New high precision digital ..
- Guanyinqiao Korean training..
- Shaanxi washing grill
- Handheld U1233A True RMS di..
- U1232A handheld digital mul..
- Shenzhen Agilent U1194A han..
- The new MS7222 RTD calibrat..
- New Products MS7221 efficac..