Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

DSO ADS1102C | Atten ADS1102C | digital storage oscilloscope

DSO ADS1102C | Atten ADS1102C | digital storage oscilloscope
DSO ADS1102C | Atten ADS1102C | digital storage oscilloscope
DSO ADS1102C | Atten ADS1102C | digital storage oscilloscope

Larger photo of automa dispenser

Company:Shenzhen, the new Bon Electronic Instrument Co., Ltd.
Information Name: DSO ADS1102C | Atten ADS1102C | digital storage oscilloscope
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
DSO ADS1102C | Atten ADS1102C | Digital Storage Oscilloscope Applications 1. electronic circuit design and debug 2. Industrial control, power measuring transient signals 3. Investigation 4. 5. Education and Training Manufacturing Test 6. Service Repair Product details Overview Aetna Letter With technology continuing research and years of manufacturing cost advantages, in order to repay long-term concern and support engineer friend, now special launch ADS1000CA Series oscilloscopes, while ensuring a powerful and high quality, the higher price to meet test engineers oscilloscope needs. Features * The new slim design, compact and easier to carry; · color TFT LCD display, waveform display more clear and stable; Rich trigger types: Edge, pulse, video, slope, alternating; Unique Digital Filter and waveform recorder; · Pass / Fail function; · three kinds of cursor mode, 32 kinds of automatic measurement functions; · 5 kinds of trigger functions: edge, pulse, video, slope, alternating 1.2 set of reference waveforms, 20 groups of common waveforms, 20 Group set up internal storage / recall; support waveform, set, CSV and bitmap files U disk external storage and recall; * Manual, tracking, automatic cursor measurement function; ? Channel waveform and FFT waveform while split-screen display; Analog and the luminance channel waveform mesh screen brightness adjustable; · pop-up menu display mode, the user operates more flexible nature; * Rich interface display style: classic, modern, traditional, simple; · independent channel control, key backlight design; · 6 hardware frequency counter display real-time count; · Multilingual interface display, the English online help system; * Standard configuration interface: USB Host: Support U disk storage and through U disk upgrade the system software; USB Device: Support PictBridge Direct printing and connecting remote control and PC; RS-232. Technical Specifications Bandwidth: 100MHZ Channel: Dual Channel + 1 external trigger channel highest real-time sampling rate: Single 500Sa / S, Dual 250MSa / S equivalent sampling rate: 50GSa / s Memory Depth: Single Channel 40K rise time: < 3.5ns Input Impedance: 1MΩ || 17pF time base range: 2.5ns / div-50s / div, Roll: 100ms-50s / div Vertical Sensitivity: 2mv-10v / div (1-2-5 sequence) vertical resolution: 8bit Display: 5.7-inch color TFT (320 * 234) LCD powerful larger voltage division 2mv / div-10v / div voltage range of gears, not only for small-signal measurements, but can not replace the probe can be directly frequency signals were observed, cost savings measure. Small signal capture noise function better, more superior performance for weak signal accurately capture subjective, so test confidence. Edge trigger type, slope, video, pulse width, alternating five kinds of trigger mode, flexible observation, various types of signal analysis, saving the cost of testing. Real-time waveform recording oscilloscopes have waveform recording function, configure flexible waveform playback mode. Waveform playback after recording the captured waveform can be no space, in real-time recording, the consistency of the observed especially for slow signals. Restore Defaults / single trigger a key recovery: a key to restore the factory settings, adjust the default parameters Single: Set detect a trigger on a waveform, then stop collecting outstanding design Delayed Scan Dual time base system The EasyZoom window scaling technology, a seamless extension of partial waveform, the overall situation, the details show. File Manager can easily operate USB storage drives and local file store. PC-side test of PC terminal software utility monitoring and control software, test automation. EasyDsoLib Software Development Kit package is to facilitate the interface library is provided secondary development, including obtaining the sampling points from the oscilloscope, version number, waveform data, set parameters, automatic measurement parameters, upload and download settings or control the oscilloscope oscilloscope interface functions. Make your development easy and efficient. EasyScope3.0 powerful control software EasyScope 3.0 monitoring software is applied to the strong performance of software systems ADS1000 family of products, the software is compatible with RS-232 and USB Device, realize the communication between the computer and the oscilloscope, so as to realize the remote control. At the same time this software can automatic real-time refresh waveform data, provide waveforms, read the measurement data, sampling data, save and print functions; complete the actual transfer of the oscilloscope screen image; in addition also has configuration upload and download capabilities; fastest millisecond-based PC the interaction between the ADS1000 series and make it easier for users to analyze, research waveforms and data. Input input coupling: DC, AC, Ground (AC, DC, GND) Input impedance: 1MΩ +/- 2% || 17pF +/- 3p maximum input voltage: 400V (DC + AC peak, 1MΩ input impedance), CAT I , CAT II probe attenuation: 1X, 10X probe attenuation coefficient setting: 1X, 10X, 100X, 1000X signal acquisition system sampling methods: real-time sampling, random sample memory depth: Dual 40K, 20K per channel acquisition modes: Sample, Peak Detect The average number of times average: 4,16,32,64,128,256 Vertical System Vertical Sensitivity: 2mV / div - 5V / div (1-2-5 sequence) channel voltage offset range: 2mV-200mV: ± 1.6V 206mV-10V: ± 40V vertical resolution: 8 bit Bandwidth: 100MHz Single bandwidth: 100MHz bass response (AC coupling, -3dB): ≤10Hz (on BNC) DC Gain Accuracy: 5mv / div-10v / div: ≤ ± 3% 2mv / div: ≤ ± 4% DC measurement accuracy (≤100mv / div): ± [3.0% X (| actual reading | + | vertical displacement readings |) + 1% X | vertical displacement reading | + 0.2 Grid + 2mV] DC measurement accuracy (> 100mv / div): ± [3.0% X (| actual reading | + | vertical displacement readings |) + 1% X | vertical displacement readings | +0.2 grid + 100mV] Rise Time (on BNC typ): <3.5ns vertical end input coupling: AC, DC, GND math: +, -, *, /, FFTFFT: Window mode Hanning, Hamming, Blackman, Rectangular; 1024 sample points bandwidth limit: 20MHz (-3dB) horizontal system real-time sampling rate: Single 1GSa / s, Dual 500MSa / s equivalent sampling rate: 50GSa / s display modes: MAIN, WINDOW, WINDOW ZOOM, ROLL, XY timebase accuracy: ± 100ppm ( at any time more than 1ms intervals) Horizontal scan range: 2.5nS / DIV - 50S / DIV Scan: 100mS / DIV ~ 50S / DIV (1-2.5-5 order) XY mode the X- input / Y- axis input: Channel 1 (CH1) / Channel 2 (Ch2) phase shift: ± 3Degrees sampling frequency: XY way to break through the traditional low-end oscilloscope limited 1MSa / s sampling rate restrictions, support 25KSa / s ~ 100Msa / s sampling rate (1-2.5 -5 order) adjustable measuring system automatically measured (32 species): maximum, minimum, peak to peak amplitude, top value and the bottom value, Cycle Mean, Mean, Cycle RMS, RMS, rising radical, radical decline, rising before shock, shock before fall, rise time, fall time, frequency, period, pulse width, positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, phase, FRR, FRF , FFR, FFF, LRR, LRF, LFR, LFF cursor measurement: manual, tracking, automatic three cursor measurement trigger system Trigger Type: Edge, Pulse, Video, Slope, alternating trigger source: CH1, CH2, EXT, EXT / 5, AC Line trigger modes: Auto, Normal, Single Trigger coupling: DC, AC, LF Reject, HF Reject Trigger level range: CH1, CH2: 6 divisions from the screen center; EXT: ± 1.2V; EXT / 5: ± 6V trigger displacement: Pre-trigger memory depth / (2 * sampling rate)), delayed trigger release 260 DIV range suppression: 100ns-1.5s Edge Trigger: Edge Type: up, down, up & Falling Pulse Trigger mode :( greater than, less than, or equal to) positive pulse width (greater than, less than, equal) negative pulse Pulse width: 20ns-10s Video Trigger Support Signal System: PAL / SECAM, NTSC hair conditions: the odd field, even field, All rows specified line slope trigger :( greater than, equal to, less than) a positive slope (greater than, equal to, less than) the negative slope; time setting: 20ns-10s Alternate Trigger: CH1 Trigger Type Edge, Pulse, Video, Slope; CH2 Trigger Types Edge, pulse width, video, slope control panel features automatic settings: auto setup function can automatically adjust the vertical system, horizontal system and trigger position Save / Recall: to provide two reference waveforms, 20 groups set up, 20 groups waveforms internal storage / recall functions; external U disk storage function hardware frequency counter Reading resolution: 6 Range: DC coupling, from 10Hz to a maximum bandwidth of the signal type: Applies to all signal normally trigger the (pulse width trigger and video trigger except ) General Specifications Display System Display Type: TFT 5.7 英寸 (145mm) LCD Display Resolution: 320 (horizontal) pixels × 234 (vertical) pixels Display Color: 64K color contrast ratio (typical) 150: 1 background intensity ( The typical): 300 nit Waveform Display Range: 8x12 grid & 8 × 18 division waveform display modes: point, vector Persistence: Off, 1 second, 2 seconds, 5 seconds, unlimited menu display: 2 seconds, 5 seconds, 10 seconds, 20 sec, unlimited screen saver: Off, 1 minute, 2 minutes, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours, 5 hours interface program: classic, modern, traditional, inside simple interpolation method: Sin ( x) / x interpolation, linear interpolation screen color modes: normal, reverse video Language: Simplified Chinese, Traditional Chinese, English, French, German, Russian, Spanish, Portuguese, Arabic, Japanese, Korean, Italian Power Voltage: 100-240 VAC, CAT II, ??automatically selects the AC power frequency range: 45Hz to 440Hz Power consumption: 50VA Max ambient temperatures: 10 ℃ to + 40 ℃ does not work: 85% RH, 65 ℃, 24 hours Cooling: fan forced cooling Humidity Operating: 85% RH, 40 ℃, 24 hours does not work: 85% RH, 65 ℃, 24 小时 working height: 3000 m does not work: 15,266m routine maintenance and cleaning routine maintenance ● store or leave the instrument, Do not leave the LCD monitor for a long time exposed to direct sunlight. ● Avoid damage to the instrument or probes, do not expose them to sprays, liquids, or solvents. Clean the probe and instrument regularly checked according to operating conditions. Follow these steps to clean the outer surface of the instrument: 1. Use a soft cloth to wipe the texture of the dust from the instrument and probe. When cleaning the LCD screen, be careful not to scratch the clear plastic protective screen. 2. Use a soft cloth dampened with water to clean the instrument, please note disconnect the power. To clean more thoroughly, you can use the aqueous solution of 75% isopropanol. ● To avoid surface damage to the instrument or probes, do not use any abrasive or chemical cleaning agents. ● Before re-use of electricity, make sure the instrument is completely dry, avoid moisture cause electrical short circuit and personal injury. Accessories - User Manual - Warranty Card - Certificate --1: 1/10: 1 probe two - so according to your country standard power wire - USB cable - CD (with EasyScope3.0 computer software systems) Warranty summary ATTEN Electronics Limited to ensure that the production and marketing of products, from the date of shipment authorized dealer for three years (annex one year) in materials and workmanship. If a product proves to be defective within the warranty period, as described in the Atten warranty providing repair or replacement service. In addition to this summary or the applicable warranty provided in addition to the warranty, Atten without any other express or implied warranty, including but not limited to, warranties of merchantability and fitness for a particular implied warranty. Atten not bear any responsibility for indirect, special or consequent damages 
Contact Detail
Company Name: Shenzhen, the new Bon Electronic Instrument Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Tan Yi()
Telephone Number: 0755-27764680
Company Address: Shenzhen, Shenzhen City, Guangdong, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450