Home
Products
TPS2014B Oscilloscopes | Tektronix digital oscilloscopes TPS2014B digital | storage oscilloscope
TPS2014B Oscilloscopes | Tektronix digital oscilloscopes TPS2014B digital | storage oscilloscope
TPS2014B Oscilloscopes | Tektronix digital oscilloscopes TPS2014B digital | storage oscilloscope
TPS2014B Oscilloscopes | Tektronix digital oscilloscopes TPS2014B digital | TPS2000B DSO digital storage oscilloscope series from the test environment to the actual environment of high efficiency. TPS2000B oscilloscope series supports up to 200 MHz bandwidth and 2 GS / s sampling rate, allowing you to make floating or differential measurements in a variety of challenging security environment. With up to four separate channels, and portable, battery-powered design, TPS2000 Series oscilloscopes allows you to quickly and accurately to overcome the most difficult challenges that you encountered in the electronic and electrical systems, and fully take into account your safety . Features Benefits 4 individual channels safe and easy way to 4-channel floating measurements, including 3-phase power measurement. Digital real-time sampling on all channels and at all times of at least 5 times oversampling to capture the signal accurately. Dedicated front-panel controls using the front-panel controls Spend less time learning and more time spent on tasks. The front panel Compact Flash? Port battery pack is quickly store and transfer your waveforms heat exchange to work where it is needed, battery life of up to 8 hours **. Weighing only 6 pounds (2.7 kg) by the lightweight and compact design facilitate transport between laboratories or transported to the site. Power measurement and analysis application module (optional) fast effective power and apparent power, phase angle, harmonics, and switching losses automated measurements. ** Standard one battery. Each battery life time of 4 hours digital storage oscilloscope TPS2012B? TPS2014B? TPS2024B Key Features and Benefits? 100 MHz and a bandwidth of 200 MHz? Up to 2 GS / s real-time sampling rate? 2 or 4 fully isolated and floating channels, plus isolated external trigger? When you install two battery can work for 8 hours, the battery can be hot-swappable, almost without an AC power source? Optional power application software, its price offers the broadest range of power measurements? OpenChoice software or integrated CompactFlash mass storage devices, archiving and analysis of measurement results quickly? All models come standard with FFT? advanced triggering, quickly capture events of interest? Traditional analog knobs and multi-language user interface, easy operation? Auto setup menu, autorange waveform memory and setup memory, built-in context-sensitive help, setup and operation quickly? menu button with backlight, visual, clear? 11 kinds of the most critical applications automatic waveform measurements? industrial power design, commissioning, installation and maintenance? Advanced electronic design, commissioning, installation and maintenance? automotive design and test? Education TPS2000 Series oscilloscopes, from the workbench to the site, providing a powerful productivity TPS2000 Series offers a range of capabilities in an oscilloscope, while providing a familiar, easy easy to use controls and menus. TPS2000 Series IsolatedChannel? Technology, is divided into 2-channel and 4-channel versions, with the ground and realize the isolation between channels, allowing you to easily measure, without fear of damage to the circuit. It comes standard with a battery, a natural choice for field applications. Test of power electronic devices, optional software integrates commonly needed power system measurement capabilities integrated into the instrument to accelerate the speed of power analysis and debugging. Were floating and differential measurements - fast, accurate, economical circuit under test Unintentionally grounding, it is a common cause of poor measurement results and circuit damaged. Connect two or more grounded probes can cause ground loops, if the current is high enough, it may lead to the destruction of components and equipment. The most important thing is, during the floating measurements, if the instruments and probes used improperly, could have caused harm personal safety. 4 IsolatedChannel "; inputs and isolated external trigger input, it can quickly, accurately and economically floating and differential measurements Tektronix IsolatedChannel technology simplifies floating measurements with different ground-referenced oscilloscopes, TPS2000 input connector housings separated from each other, at the same time. also separated from the ground. within the specified 600 VRMS maximum float voltage range, IsolatedChannel techniques prevent current between TPS2000 input BNC shells or from any current BNC shell to earth. Tektronix offers a different passive probe, depending on the application through standard P2220 passive probe in 10X mode, TPS2000 can measure up to 400 voltage Vp-p However, in order to meet safety rating P2220 probe reference lead must be kept relatively grounded 30 VRMS range. For this reason, P2220 probe is particularly suited to handle the maximum voltage does not exceed 30 VRMS digital and analog circuits. Input signal and float voltage maximum safety ratings measurements power conversion electronics usually require relatively nominal voltage high probe Tektronix offers two passive probes to make floating measurements with specially designed insulation system. Optional P5122 probes, when used in conjunction with the TPS2000, the device is suitable for measuring 480 VRMS II environment, relative to ground maximum float voltage of up to 600 VRMS. With the optional P5120 probe, TPS2000 can measure up to 800 Vp-p voltage relative to ground maximum float voltage is within the range of 600 VRMS. For complete safety ratings and technical data, See "Features" section. Select the appropriate probe oscilloscope / probe work (attenuation) Maximum safety ratings TPS2000 can view the signal reference float Safety Rating * 1 Input Signal Safety peak to peak voltage rating screen (around 0 V Center sinusoidal) on the screen RMS Voltage (centered around 0 V sinusoidal) TPS2000 input (1X) 600 VRMSCAT II 300 VRMSCAT II 40 Vp-p 14.1 VRMS P2220 (10X Settings) 30 VRMS 300 VRMSCAT II 400 Vp-p 141 VRMS P5120 (20X) 600 VRMSCAT II 1000 VRMSCAT II 800 Vp-p 282 VRMS P5122 * 2 (100X) 600 VRMSCAT II 1000 VRMSCAT II 2828 Vp-p 1000 VRMS * 1 passive probe reference lead no attenuation so any working voltage or overvoltage transients pass straight through to the scope reference. Therefore, the passive probe reference float rating can never exceed the scope reference float rating. * 2 The P5122 probe should not be used for AC-coupled measurements on signals with greater than 300 V DC offset. The P5120 is the recommended probe for measuring ripple on high-voltage DC supplies. Speed ??up industrial power systems and circuit design and test rate from mobile phones to work with motor drives, power conversion technology in the specifications, performance, and energy efficiency have made considerable progress. However, even viewing the converter input and output this basic task, when there are multiple voltage reference source will become very complicated. Multiple references also allows simultaneous viewing of the control circuit and power circuit signal becomes challenging. If there is no corresponding differential probe, using ground-referenced oscilloscopes in these applications may damage the circuit, get good measurement results. For debugging power conversion electronics, IsolatedChannel technology reduces the risk of damage to the circuit and non-circuit interactive behavior is expected. For performing power system measurements, TPS2000 TPS2PWR1 optional power application software. It is the entry-level price on the oscilloscope provides advanced power measurements. In measuring the performance of switching devices, power application software for the TPS2000 adds significant measurement functions, including automatic switching loss, dv / dt and di / dt cursor measurements. Variable frequency drive performs phase three power measurements using TPS2PWR1 software harmonic distortion measurements. For the measurement and inspection of their impact on the power distribution system in the AC line voltage, power application software shows harmonic 50th harmonic components, providing a phase, reactive power and power factor measurements. By 4-channel TPS2014 or TPS2024, you can see the three-phase voltage or current. Two power "bundles" are available, including probes and measurement software. Each kit comes with four probes and TPS2PWR1 power application software, the price is lower than the purchase price alone. TPS2PBND including four P5120 20X passive high-voltage probes and TPS2PWR1 power application software. TPS2PBND2 combines four P5122 100X passive high-voltage probes and power application software. Use DRT sampling technology, the rapid debug and test signals in real time using digital (DRT) sampling technique using the first time to capture elusive glitches. Use TPS2000 Series Digital Real-time (DRT) sampling technology, on up to four channels verification signal types. This acquisition enables you to capture high-frequency events, such as glitches and edge anomalies, while other oscilloscopes in these events are not detected, so you can see exactly what your signal. Easy analysis and archiving measurement results using OpenChoice software and integration CompactFlash mass storage, archiving and analyzing measurements speed up work. Use TPS2000 Series Fast Fourier Transform (FFT) function and frequency domain analysis, quickly revealing signal interference, crosstalk, and vibration. Using the integrated CompactFlash mass storage or OpenChoice PC standard software and easily analyze and document measurement results. From the bench to the laboratory, to live, to correlate the measurement results up * 3 TPS2000 Series uses highly portable, the measurement results table, between laboratory and field easily associate. Hot-swappable battery, AC power almost without limit. TPS2000 a highly mobile package, battery longest continuous working time in the industry, you can work bench, in the lab or in the field using the instrument. By using the hot-swappable battery, you almost without AC power restrictions. Optimize production efficiency per channel independent mode dial and backlit menu buttons, even in challenging operating environment, can still easily use the oscilloscope. Oscilloscope with the most users are familiar with the layout of the front panel. Each channel have a dedicated scaling and position control. By automatically setting, automatic range, automatic measurements, probe check wizard, and context-sensitive help function, you can shorten the measurement time. Backlit menu button can help you in a variety of challenging work environment, from bright sunlight to dimly lit areas. * 3 Please refer to Environmental and Safety Technical Data
Contact Detail
Company Name: | Shenzhen, the new Bon Electronic Instrument Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Tan Yi() |
Telephone Number: | 0755-27764680 |
Company Address: | Shenzhen, Shenzhen City, Guangdong, China |
Zip/Postal Code: |
Find More Related Products
- TPS2024B Oscilloscopes | Te..
- Shipping Italy Luoer Xi ROS..
- "Guangxu ingot Ministry mad..
- Fluke177 Instrument Co., Lt..
- MAS830L wholesale company i..
- Ninety-nine equipment for s..
- Also known as the radius of..
- VICTOR187 digital multimete..
- Digital speed cycle table S..
- Digital Signage Digital Sig..
- Special advertising _ recta..
- Right Angle Rainbow series ..
- Supply of the United States..
- Supply PE graphite tube
- ZTE S330 single STM-4 optic..
- Toyo (CUSTOM) multimeter M-..
- Toyo (CUSTOM) Clamp Multime..
- Vertical Special advertisin..
- 42 Vertical Special adverti..
- Dual LCD advertising machin..