Air conditioning is not cooling because air conditioning _ _ Li Xiang Electric

Air conditioning is not cooling because air conditioning _ _ Li Xiang Electric
Air conditioning is not cooling because air conditioning _ _ Li Xiang Electric
Air conditioning is not cooling because air conditioning _ _ Li Xiang Electric

Larger photo of automa dispenser

Company:Appliance Sales Co., Ltd. Chongqing Li Xiang
Information Name: Air conditioning is not cooling because air conditioning _ _ Li Xiang Electric
Update Time:2015-04-30
Validity:0
Specifications:Limited
Quantity:
Price Description: RMB/
Inquire Now
 Air conditioning installation location - Chongqing Li Xiang Electrical Appliance Sales Co., Ltd. General Air conditioning installation location should be away from heat, hot air exclusion and noise should not affect neighbors. Installation height of the outdoor unit should be lower than the indoor unit air conditioner disease, which is conducive to circulating refrigerant oil. Install the outdoor unit should be no short-circuiting of hot air circulation, so as not to affect the heat: the installation location should be conducive to the maintenance, easy drainage and do not affect pedestrians, to avoid or stay away from power lines, there are places and flammable and explosive radiation. The indoor unit is installed in front of the barrier should not have, and to ensure that cold (or hot) jet from the indoor temperature more uniform. Air conditioning maintenance - Chongqing Li Xiang Electrical Appliance Sales Co., a general air conditioning maintenance period. Clear vent debris to ensure proper ventilation. Observation outdoor rack without loosening, clean outdoor ventilation grille anything on it. At the same time, keeping the vents unobstructed. 2. Indoor and outdoor heat exchanger surface cleaning, improve the efficiency of heat exchangers. When cleaning the indoor heat exchanger, won the panel should be careful, scrub with a soft cloth, using a small brush to gently scrub the finished heat exchanger inside the machine, so to achieve the clear purpose of dust and harmful bacteria can multiply accumulations. However, note that due to the heat sink is a thin aluminum material, easily deformed by the force, so be careful brushing. 3. Cleaning the filter net fouling. Clean the filter in time, turn the power off, then play moved into the wind gate; remove the filter, clean the filter with water or vacuum cleaner, the water temperature should not exceed 40 degrees, with a hot, damp cloth or neutral detergent, then wipe with a dry cloth net, but can not clean the filter with pesticides or other chemical detergents. 4. Cleaning dirt drainage portion and the accumulations. Drainage section easily deposited dirt must be regularly disinfected, to ensure smooth drainage to prevent bacterial growth. 5. Check the other. Including power lines, plug boards that switch; check easy to wear and tear parts, such as wind rotation plate, sterilization dehumidification, photocatalyst and other parts situation, ensure good air conditioning no exception. Central air conditioning maintenance - Chongqing Li Xiang Electrical Appliance Sales Co., Ltd. home care and modern architecture as "lungs", central air conditioning system charged with the invention and maintain a warm indoor air environment burden. If its operation is not good, not only ineffective but also showing the formation of air conditioning energy consumption, equipment problems and other issues. Among them, the central air-conditioning maintenance of a home for the most important part. Home central air conditioning maintenance to meet the fundamental purpose of the use of the request, the primary purpose of the system operation management and maintenance of home for. About an enterprise, from the guide, down to the staff, we must clearly coiled central air conditioning system operation management of all the work done, it is requested in order to meet the use, reduce operating costs and extend the service life of these three objectives. That is the most economical cost in exchange for the highest overall performance, the completion of the largest economic benefits. Home central air conditioning maintenance, reduce operating costs in addition to labor costs, operating costs including energy consumption and maintenance home for fees; According to statistics, in accordance with the manufacturers request timely maintenance of the machine to reduce annual operating costs by 10% -20%. Home central air conditioning maintenance to extend the service life of central air conditioning duct systems, control systems and the use of relatively short life ends mounted air conditioner is not cooling reasons, so its direct impact on investment in equipment depreciation period and updating of funds, and therefore the use of life should be at least reach the intended use of life, beyond the better, this will enable the update late investment funds, so that the entire lower operating costs. Material statistics air conditioning, home for long-term maintenance of central air-conditioning system is not the average life expectancy for a good home for the machines are not in place or home for 2--5 years. As a systems engineering, central air time investment is large, including many kinds of equipment, its operation, maintenance, care of themselves, each local maintenance indispensable. As the first indoor environmental experts cozy, warm 100 net central air conditioning system's main target is to serve people, central air-conditioning maintenance enjoying priority is people-oriented, ensure that requests indoor air environment, completing the best heating and cooling effect. Air conditioning is not cooling because air conditioning _ _ Li Xiang, Li Xiang appliances provided by the Chongqing Electric Sales Co., Ltd. Chongqing Li Xiang Electrical Appliance Sales Co., Ltd. (www.cqlixiang.com) strong, credible, in Chongqing Chongqing wall machine industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving innovative ideas will lead Cheung electrical excitation into the brilliant and you work for a better future! 
Contact Detail
Company Name: Appliance Sales Co., Ltd. Chongqing Li Xiang
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Hu Chuan()
Telephone Number: 023-63202028
Company Address: North Zone of Chongqing Jinshan Road 203 attached to the 11th, , Chongqing, China
Zip/Postal Code: 400000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450