Power equipment MZ-6880 cable fault tester
Power equipment MZ-6880 cable fault tester
MZ-6880 cable fault tester can test various types of power cables (voltage 1KV ~ 35KV) and telephone cable, FM communication cables, coaxial cables and metal short circuit on overhead lines, grounding, high resistance leakage, high resistance flashover failure and cable breakage, contact failure and other failures. And test cable length and wave propagation speed in the cable. Independent production better prices, sale and one year free warranty and lifetime maintenance, welcomed the order. First, the delivery flow and power Introduction wired communication depends on the normal operation of cable W lines. Once the line barriers, not timely detect fault and quickly be excluded, it will cause great economic losses and adverse social impact. Thus, cable fault tester is an important tool to maintain the various cables. Intelligent cable fault tester using a variety of fault detection methods, the application of the most advanced electronic technology achievements and devices using computer technology and the special nature of electronic technology, combined with the company's long-term development of successful experience in cable tester of the launch of the high-tech, intelligent, full of new products. Cable fault tester is a comprehensive set of cable fault detection equipment. Capable of cables flashover failure, low resistance grounding, short-circuit and cable break, poor contact failure test, if equipped with cable locator, accurate determination of the exact location of the fault. Especially suitable for testing various models, different levels of voltage power cables and communication cables. Second, the main technical parameters 1, the application and use of the instrument can test various types of power cables (voltage 380V ~ 35KV) and telephone cable, FM communication cables, coaxial cables and metal short circuit on overhead lines, ground, high leak resistance, high resistance flashover fault and cable break, poor contact failure. And test cable length and wave propagation speed in the cable. 2, the farthest test distance: 15Km (open air up to 100 kilometers) 3, blind spot detection: 1m 4, reading resolution: 1m 5, power consumption: 5VA 6, using the conditions: ambient temperature 0 ℃ ~ + 40 ℃ (limit temperature -10 ℃ ~ + 50 ℃) Relative humidity 40 ℃ (20 ~ 90)% RH atmospheric pressure (86 ~ 106) Kpa 7, volume: 275 × 220 × 160mm3 8, Weight: 1.8kg
Contact Detail
Company Name: | Wuhan Science and Technology Co., Ltd. Zhou Mei |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Xu() |
Telephone Number: | 027-87929296 027-87929279 |
Company Address: | Wu Tai Hang domain A7, , Hubei, China |
Zip/Postal Code: |
Find More Related Products
- MZ-8800 relay protection te..
- Supply Wuhan chow phase cap..
- Manufacturers supply steel ..
- Zhejiang Siping HongRun gen..
- Chip electrical impedance v..
- MZ-8852SF6 trace moisture m..
- Tengen construction softwar..
- SUPCON XP363B Siping HongRu..
- Siping HongRun xp362b SUPCON
- Zhejiang Hongrun authentic ..
- SUPCON XP248 Siping HongRun
- 800T-PC416GGBG Rockwell tra..
- Power Rectifiers Rectifier ..
- MZ-6810 transformer turns r..
- US HAMMOND transformer
- Switzerland Wagner + Grimm ..
- US RSISOLSEC transformer
- Netherlands Oltronix transf..
- Qing Quan discharge capacit..
- lelon aluminum electrolytic..
- Ultra-small electrolytic ca..