Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Yongkang brand new generation of home combustible YK-828RQ / 13

Yongkang brand new generation of home combustible YK-828RQ / 13
Yongkang brand new generation of home combustible YK-828RQ / 13
Yongkang brand new generation of home combustible YK-828RQ / 13

Larger photo of automa dispenser

Company:Shenzhen Yongchang Electronic Co., Ltd.
Information Name: Yongkang brand new generation of home combustible YK-828RQ / 13
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Yongkang home combustible New YK / QR13 YK-828 / QR13 product diagram (imported chips, alarm sounds great, much customers) 1. The main parameters Detection of gas: natural gas, LPG, city gas (H2) Operating voltage: 220VAC or 110VAC, 12VDC-24VDC Working temperature: -10 ℃ - + 50 ℃ Working environment: Humidity ≤97% RH linkage function: can be equipped with interlocking row air fan, manipulator, solenoid valve Networking: Wired networking: (NO, NC) Wireless networking mode: 315MHZ / 433MHZ (2262 OR 1527) Product Specifications: Weight: 240g Dimensions: 110 * 70 * 40mm Box size: 144 * 105 * 53m 2. The basic function of the gas leak detector is the company developed the production of security products, widely used in the family unit and use safety precautions artificial gas, natural gas and liquefied petroleum gas equipment alarms. The scene of the gas leak occurred in a timely alarm, and external alarm signal and automatically start ventilation equipment, automatic shut off the gas pipeline valves, ensure the safety of your life and property. a. by sensor drift automatic compensation function to prevent false positives and false negatives, at present this technology domestic initiative. b., the sensor automatically prompts damage to the user to replace and repair, to prevent the report. c. You can bring fan, manipulator, solenoid valve, when an alarm occurs robot can automatically close the valve, solenoid valve, open the exhaust fan. So it can achieve 24-hour alarm handling capabilities, and better protect the safety of users. 1. Install a location alarm installation location: within a radius of 1.5 meters from the gas source range, well-ventilated place:. B gas, natural gas - lighter than air, floating aloft, wireless gas detectors should be installed in the upper portion of the gas source. Installing the wireless gas detectors and gas appliance or valve horizontal distance of not greater than 6m, mounting height from the ceiling should be less than 0.3m, and shall not be located above the gas appliance. c LPG - heavier than air and deposited on the lower, wireless gas detectors should be installed in the lower portion of the gas source. Installing the wireless gas detectors and gas appliance or valve horizontal distance of not greater than 3m, installation height from the ground should be less than 0.3m. d not install alarm Location: corner cabinet and other positions is not easy flow of air; direct smoked soot and other location easily. 2. L Installation of the wall at the selected location, corresponding to the mounting plate two random installation holes ready punch mark (on-board hooks should level up); lay the mounting holes into the supplied installation stopper, then random tapping screws fixed to the wall mounting plate; three holes on the back of the body aligned mounting plate fixed hooks, hang the body; the connection-related output signal, the power. I. Description a. Application 1. Power light: green, power and lights up when the alarm goes off. Lights: red, alarm lights, stop the alarm goes off. 2. Power, green light or flashing three minutes later, the alarm began to work properly. 3. When the detected gas reaches the alarm point, the alarm began to alarm, green light is off, lights lit, the buzzer "BB .." sound the alarm, when the concentration of the detected gas down to the alarm point, the alarm is stop the alarm. (Carbon monoxide alarm has delay function) 4. It adds manual detection function, when pressing a button, the green light is off, lights lit, the buzzer "B, B ..." sound the alarm. 5. If the increase in the United fan function, when the alarm alarm, has been connected to the exhaust fan started automatically remove harmful gases. 6. If the increase in the United manipulator or solenoid function, when the alarm alarm, has been connected to the robot or the solenoid valve will automatically close the gas valve, thereby cutting harmful gas source. 7. If you increase the networking function, when the alarm alarm management center or the control center at the same time receive normally open and normally closed (NO, NC) signal. (For increased wireless capabilities, the control panel will receive a radio signal 2-3 seconds) after an alarm output relay passive contact signal (normally open, normally closed can be patched) for controlled ventilation ventilation equipment or other devices normally open or normally closed for the alarm contacts. b. Notes 1. The alarm shall be easy to observe, easy to check the position of the jet is attached to. 2. The alarm shall be installed in a gas appliance, it may leak rooms 3. Prohibited in the installation process, vibration, drop, shock alarm, otherwise the alarm will fail. 4. Alarm installation position, not being on the gas fumes. 5. Alarm not be installed in a well-ventilated or air-large. 6. The alarm can not be obscured other objects. 7. Alarm not be installed next to the refrigerator, air conditioning, etc. vibrating object. 8. When the green light flashes, the jet can not be checked. 9. Do not spray paint around the alarm, spraying a large amount of irritating gas, such as pesticides, alcohol and the like. c. After the police approach 1, open immediately doors and windows, turn off air supply hazards can not be turned on or off any electrical switches. 2, report immediately to the gas management, check processing performed by professionals. 3, after the professionals, respond to alarms do aeration process. d. Scope of household gas leak alarm widely used in many fields of urban security, residential, factories, companies, schools, families, villas, warehouses, resources, petroleum, chemical, gas transmission and distribution. Can be used alone, it can also be networked with the controller host. Second, the company's main and sale of the company's main products: carbon monoxide alarms, home combustible gas, car combustible gas, temperature alarms, smoke alarms, water leakage overflow alarm, industrial gas alarm. Certification: CE certification, 1 million of insurance, the state gas appliance testing report, explosion-proof electrical equipment certification Transportation: Express / Logistics (Express pays shipping, logistics and free) Delivery time: 7 days service: the date of receipt of the three During the month the product belongs to quality problems Baohuan year free warranty (to be our engineering department to check human damage either). Quality assurance: We are Shenzhen Yongchang Electronic Co., Ltd. manufacturers, wholesale, product reliability, quality problems, please contact me. ! ! ! Please note that all customers, as domestic gas, gas alarm popularity, there have been many counterfeit products on the market! ! Buy products, please look for the regular products within product packaging: an alarm / a Manual / a certificate / an insurance card / 二颗 screw Yk-828 / RQ13 second analysis Yong Kang designed to follow the combustible gas national standards GB15322.2-2003 and CJ3057-1996 "household gas leak alarm" standards. Product Name: Yong Kang combustible gas / detector Model: YK-828 / RQ13 Brand: Yongkang Product composition: ABS fireproof enclosure, power lines, circuit boards, sensors, buzzers, transformers, chip, capacitors, resistors, etc. Features: CCTV CCTV co-branded, 1 million Pacific liability insurance, high-precision sensor product range: Yong Kang combustible gas / detectors are widely used in urban security, residential, factories, companies, schools, families, villas, warehouses, resources , petroleum, chemical, gas distribution, and other fields. Can be used alone, it can also be networked with the controller host. Picture: home combustible gas / detector generates origin: With the overall improvement of national West-function, many families use to natural gas. Gas brings the convenience of the people at the same time, natural gas leaks in time to bring harm to the people is very large. So people will be able to detect need for a natural gas / gas leak detectors / alarms to protect the gas safety of the people. So Yongkang brand gas leak alarms / detectors to meet market needs, turned out to protect the family safe use of gas people. Yongkang brand household gas leak alarm function Yongkang brand household gas leak alarm for gas, natural gas, liquefied petroleum gas and other combustible gases using existing sites, due to the combustion gas leaks, explosion, poisoning and other accidents can be safe detection and alarm . Yong Kang feature of the product gas leak detector with high sensitivity, high stability, all types, small size and other characteristics. Its linkage type control signal can also be output contacts, linked solenoid valves, robots, exhaust fans and other equipment operation, can find a gas leak in the early and tell the user process, while its control system can also cut off the gas, hit the day row air fan, prevent serious bombings, this product is the family of essential products, with it, you'll feel very 安全永 Kang gas alarm combustible gas production standards and complies with the design of national GB15322.2-2003 and CJ3057-1996 "household gas leak alarm" standards. Yong Kang natural gas leak from the power line, ABS fireproof enclosure, circuit boards, sensors, transformers, buzzers, chips, resistors, capacitors alarm products alarm structure. Standard power line: 1.5 m Housing: ABS fireproof material boards: a substrate, a copper foil and a binder sensors: inlet sensor, the sensitive element, switching element, the transformer switching circuit of three parts: a magnetically permeable material, a conductive material insulating materials buzzer: electromagnet, permanent magnet hoop, shock film, transistor, self-excited oscillator consisting of chips: the Northbridge and Southbridge resistance: constantan alloy capacitance: an anode foil, a cathode foil, paper capacitors, electrolytic liquid extraction electrode foil, aluminum guide pin (mini), aluminum housing, heat shrink tubing and other components product structure is as follows Yongkang brand gas leak alarm design rationality air inlet disposed below the alarm and left and right sides in favor of disclosure into the gas. According to most customers design proposal lantern, layout is very practical, when the alarm does not affect the family atmosphere lantern sort of careful market research, chose this recognition and likeability highest profile patent manufacturing, in line with market demand Appearance diagram: Yong Kang gas leak detector parameters * Item Description 1 CCTV trademark branding with CCTV CCTV Channel reached a designated partner 2 ABS shell fire on the market using the best quality ABS fireproof material The housing 3 green power light when the alarm is plugged in, the green light flashes 3-5 minutes into the function 4 yellow fault light when the alarm is in working condition, the internal components in question will automatically alarm 5 red lights when the alarm gas leak is detected concentration reaches the alarm value, the red lights flashing alarm 6 gas inlet gas inlet port 7 power plug 220V household power plug detect the type of gas: natural gas, coal gas, liquefied petroleum gas Operating Voltage: 12V, 24V, 110V, 220V work Temperature: -10 ℃ - + 50 ℃ Working environment: Humidity ≤97% RH Operating Current: 200Ma Weight: 240g Dimensions: 110 * 70 * 40mm Box size: 144 * 105 * 53m Additional features: Linkage pipe robot, joint pipeline solenoid valve, linkage exhaust fan features Networking: 1. Wired networking: relay output, shock output, normally open and normally closed output, switch signal output and building systems, fire docking system 2. Wireless networking: wireless frequency 315MHZ / 433MHZ (2262 OR 1527) RF output Yong Kang home combustible gas use Introduction. Power light: green, power and lights up when the alarm goes off. 2. Lights: red, alarm lights, stop the alarm goes off. 3. When powered, flashing green lights for about 3 minutes, combustible gas uttered B into the normal working condition. 4. When the detected gas reaches the alarm point, the alarm began to alarm, green light is off, lights lit, the buzzer "BB .." sound the alarm, when the concentration of the detected gas down to the alarm point, the alarm is stop the alarm. (Carbon monoxide alarm there is a delay function) 5. It adds manual detection function, when pressing a button, the green light is off, lights lit, the buzzer "B, B ..." sound the alarm. 6. If the increase in the United fan function, when the alarm alarm, has been connected to the exhaust fan started automatically remove harmful gases. 7. If the increase in the United manipulator or solenoid function, when the alarm alarm, has been connected to the robot or the solenoid valve will automatically close the gas valve, thereby cutting harmful gas source. 8. If you increase the networking function, when the alarm alarm management center or the control center at the same time receive normally open and normally closed (NO, NC) signal. (For increased wireless capabilities, the control panel will receive a radio signal 2-3 seconds) after an alarm output relay passive contact signal (normally open, normally closed can be patched) for controlled ventilation ventilation equipment or other devices normally open or normally closed for the alarm contacts. Yongkang household gas leak alarm installation instructions Installation requirements a gas alarm installation location: about 1.5 meters from the gas source radius range, well-ventilated place. . b gas, natural gas - lighter than air, floating at high levels, gas detectors should be installed in the upper portion of the gas source. Install gas detectors and gas appliance or valve horizontal distance of not greater than 6m, mounting height from the ceiling should be less than 0.3m, and shall not be located above the gas appliance. c LPG - heavier than air, accumulate in low, gas detectors should be installed in the lower portion of the gas source. Install gas detectors and gas appliance or valve horizontal distance of not greater than 3m, installation height from the ground should be less than 0.3m. d not install alarm Location: corner cabinet and other positions is not easy flow of air; direct smoked soot and other location easily. 1. Installation position in the selected wall, corresponding to the mounting plate two random installation holes ready punch mark (on-board hooks should level up); lay the mounting holes into the supplied installation stopper, then randomly tapping screws fixed to the wall mounting plate; three holes on the back of the body from the fixed mounting plate hooks, hang the body; the connection associated output signal line, power. Yongkang gas leak detector Caution 1. The alarm shall be easy to observe, easy to check the position of the jet is attached to. 2. The alarm shall be installed in a gas appliance, it may leak rooms 3. Prohibited in the installation process, vibration, drop, shock alarm, otherwise the alarm will fail. 4. Alarm installation position, not being on the gas fumes. 5. Alarm not be installed in a well-ventilated or air-large. 6. The alarm can not be obscured other objects. 7. Alarm not be installed next to the refrigerator, air conditioning, etc. vibrating object. 8. When the green light flashes, the jet can not be checked. 9. Do not spray paint around the alarm, spraying a large amount of irritating gas, such as pesticides, alcohol and the like. Yongkang gas leak detector alarm after effective approach 1, open immediately doors and windows, turn off air hazards can not be turned on or off any electrical switches. 2, report immediately to the gas management, check processing performed by professionals. 3, after the professionals, respond to alarms do aeration process. 
Contact Detail
Company Name: Shenzhen Yongchang Electronic Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Huang Shun(Business Manager)
Telephone Number: 0755-66800128 0755-29691969
Company Address: North manhole Republican Wing of the third floor of 28 Science Park, , Guangdong, China
Zip/Postal Code: 518104
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450