Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Who knows how the measured thickness of paint coating thickness MCT200 low spot price sales

Who knows how the measured thickness of paint coating thickness MCT200 low spot price sales
Who knows how the measured thickness of paint coating thickness MCT200 low spot price sales
Who knows how the measured thickness of paint coating thickness MCT200 low spot price sales

Larger photo of automa dispenser

Company:Shijiazhuang fly instrument Co., Ltd.
Information Name: Who knows how the measured thickness of paint coating thickness MCT200 low spot price sales
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
 MCT200 coating thickness Introduction 1 Overview MCT200 portable coated (plated) layer thickness is the crystallization of high-tech, which uses chip technology, high-precision, bright screen, digital display, showing the value of a stable level, responsive, low power consumption , simple operation, no correction knob, single probe measurement of full scale, small size, light weight, beautiful; and having a store, read, low voltage indication, the performance of similar instruments to achieve the contemporary international advanced water, it can quickly, no damage, to carry out precision coating, coating thickness measurement, but also for film thickness measurement. The instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and testing fields, is the material necessary to protect the professional equipment. Both for the laboratory, it can also be used for engineering field. 2 Technical parameters? The instrument uses magnetic and eddy current two thickness measurement methods can be used to measure magnetic induction magnetic coating all non-magnetic substrate (such as steel, iron) on (such as paint, coating, zinc coating, plating layer etc.). Eddy current can be used to measure all non-magnetic metal (such as copper, aluminum, stainless steel) above the non-conductive coating (e.g., paint, coating, oxide film). Measuring range: (0 ~ 1250) μm (F1, N1 probe), F10 probe up to 10mm; Resolution:?? 0.1μm (F1, N1 probe) Indication accuracy: ± (3% H + 1) ? μm; H is the measured coating thickness display method: displays high-contrast segment code LCD, high brightness EL backlight; storage capacity:? can store 20 groups (up to 50 measurements) measurements units: Metric? (μm), inch (mil), the operating voltage can be freely converted:? 3V (two AA alkaline batteries) Continuous working time:? more than 200 hours (backlight off) Communication interface:? USB1.1, with PC connections, communications Dimensions:?? 125mm × 67mm × 31 mm type, the operation is very simple. ? You can set upper and lower limits, the measurement result is greater than equal to the lower limit value, the instrument will issue the corresponding sound or flashing lights prompt. ? High stability, no adjustment can be long-term use. ? Can be a single or multiple data delete operation has beep prompt to be prompted by an error screen or a beep with five statistics:??? Mean (MEAN), maximum (MAX) , minimum (MIN), the number of tests (NO.), standard deviation (S.DEV)? By selecting the appropriate probe can measure magnetic metal matrix on the non-magnetic coating thickness, can be measured non-magnetic metal matrix the thickness of the non-conductive coating;? With probe zero calibration point calibration, two-point calibration, and basic calibration method can be used for system error correction probe;? With measurement status prompts;? There are EL backlit display, easy to use in dimly lit environments;? There are remaining battery indicator, real-time display remaining battery charge;? has automatic sleep, automatic shutdown and other power-saving features;? with USB1.1 communication interface, the measured values ??can be transferred to PC machine. ? Optionally be equipped with computer software, with transmission measurements, the measured value storage management, statistical analysis of the measured values, the measured value print reports and other rich features;? With aluminum housing, compact, portable, solid and durable, suitable for harsh operating environment, anti-vibration, shock and electromagnetic interference; MCT200 portable coated (plated) layer thickness meet the following criteria:? GB / T 4956─2003 magnetic substrates of non-magnetic coatings - Measurement of coating thickness - Magnetic method GB / T 4957─2003 non- magnetic metal matrix coating layer non-conductive coating thickness measurement Eddy current JB / T 8393─1996 magnetic, eddy current coating thickness gauge JG 818─2005 "magnetic, eddy current coating thickness gauge" 3, instrument configuration No. Name Quantity Remarks Standard Configuration 1 host 1 2 F1 or N1 probe a probe calibration sheet 5 4 3 zero matrix an optional carrying case according to the probe 5 1 6 random data 1 7 AA (5 号) size alkaline battery Optional 2 8 9 Other types of probes depending on the use to select a set of 10 data management software software CD 11 USB communication cable 1 4 Working conditions Temperature: Operating temperature -20 ℃ ~ + 50 ℃; storage Temperature: -30 ℃ ~ + 70 ℃ Relative humidity ≤90%; the environment without a strong vibration, no strong magnetic field, corrosive medium and severe dust. 6 Notes MCT200 portable coated (plated) layer thickness gauge is a high precision, wide application of the instrument. In order to ensure the long-term instrument accuracy and stability, please use the following instructions: To keep the instrument clean, do not drop avoid high altitude in a dusty, humid environment operations, the principle of corrosive chemicals and steam. After using the instrument, please put in the deposit box. Not a long exposure, the temperature will affect the measurement accuracy. Most of the instrument housing can withstand aggressive chemicals, clean with a soft cloth to clean the probe to ensure accurate measurement results do not remove the batteries for a long time, to avoid corrosion motherboard battery fluid leakage. Shijiazhuang fly instrument Co., Ltd. Wang Yuan: 13833160310 QQ: 1972044088 Address: Yuhua District, Shijiazhuang International Mingdi B2401 
Contact Detail
Company Name: Shijiazhuang fly instrument Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang Yuanyuan(Sales)
Telephone Number: 0311-80772346
Company Address: Donggang Road Yuhua District, Shijiazhuang City, 150 East is still an oasis 8-1-1002, Shijiazhuang City, Hebei Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450