Water-cooled diesel generator 100KW / 100KW diesel silent generator
Water-cooled diesel generator 100KW / 100KW diesel silent generator
Water-cooled diesel generator 100KW / 100KW diesel generator Silent diesel generator engines triangle Check rubber band tension and adjustment of diesel engine generator set, triangular rubber band should maintain a certain degree of tension. Under normal circumstances, the rubber in the middle of the triangle plus 29-49N (3-5kgf) pressure tape, adhesive tape should be pressed 10-20mm distance. Too tight will cause the alternator, fan and water pump bearing wear increased on; too loose will cause the driven accessory reach the required speed, resulting in the charge generator voltage drops, fan air flow and reduce pump flow, thus affecting engine normal operation, there should be regular triangle rubber belt check and adjust the tension. Diesel generator engines tension triangle rubber belt, may, by changing the position of the alternator bracket to adjust. When the triangle rubber belt tightness of fit, will stay fixed. Proper use and to grow rubber band triangle, triangle beneficial to extend the life of the rubber band, is generally used for no less than 3500h. When the triangle rubber belt elongation occurs due to excessive delamination and can not achieve the required progress should namely Zhang replaced. At the time of purchase and exchange of triangular rubber belts, should pay attention to the type and length of the new band and the original with the same triangular rubber band. If a group of two or more of the same triangular rubber band, but also the selection of the actual length of almost the same as a group, or not with the rubber band triangle uneven tension easily damaged. Learn more 多特赫 generator related technologies; please call factory Tel: 021-31253661 18721346689 QQ: 771585756 Contact: Pang Jingli generator set models TH100GF Standby Power (KW / KVA) 105/132 prime power (KW / KVA) 100 / 125 Number of cylinders inline 6-cylinder Bore X Stroke mm 105x125 Displacement L 6.49 Rated speed r / min 1500 fuel consumption g / kw · h ≤224 diesel engine type inline, water-cooled, four-stroke voltage V 230/400 frequency Hz 50 Phase Phase 3 Rated current A 190 Power factor 0.8 Wiring phase four-wire, Y type connection Excitation Brushless, self-exciting open-shelf open-shelf unit dimensions mm 2675x1090x1550 Weight kg 880 Dimensions mm 2700x1100x1560 Mute Mute Net weight kg 940 Deutz diesel generators, 25kw diesel generators, diesel generator oil, diesel generator construction, design diesel generators, diesel generator batteries, diesel generators Ltd., diesel generator running, diesel generators the tender, 350kva diesel generator, 600kva diesel generator This year's hot machine prices, the diesel generator room environmental protection, cleaner diesel generators, diesel generators antifreeze, water-cooled diesel 100KW diesel generator / diesel silent generator 100KW diesel generator Precautions to high temperatures of so many people impressive, constantly refreshed throughout the electricity, many users began using emergency diesel generator. Yes, this hot weather, the safe use of diesel generators will increase the number of difficulty. First, the normal ambient temperature generator set itself should not exceed 50 degrees, a temperature of more than this, if equipped with automatic protection function of the diesel generator set also does not matter, it will automatically alarm and shutdown. However, if there is no protection of diesel generator failure occurs, there may be an accident, so the Haite He remind the majority of users, the hot weather, the use of diesel generators must pay attention to safety. In particular, the generator room must be ventilated, preferably open windows and doors, to ensure the engine room temperature can not exceed 50 degrees. Secondly, because of the high temperatures, diesel generator operator wearing than less at this time, when the generator is operating diesel generator room must pay attention to safety, to prevent the diesel generator water tank because the temperature is high and boil, it is possible the water will splash everywhere and wounding. Finally, in this hot weather, as far as possible so that the diesel generator room temperature not too high, the cooling conditions should be the job, so as to ensure generators from damage, but also to avoid accidents. Learn more 多特赫 generator related technologies; please call factory Tel: 021-31253661 18721346689 QQ: 771585756 Contact: Pang Jingli
Contact Detail
Company Name: | Te He Industries (Shanghai) Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Pang Jingli(Manager) |
Telephone Number: | 021-31253661 |
Company Address: | Cream Bamboo Road, Jiading District, 4490, Shanghai, Shanghai, China |
Zip/Postal Code: | 201800 |
Find More Related Products
- C61 non-metallic ultrasonic..
- HC-U83 nonmetallic ultrason..
- Hospital sewage treatment e..
- Portable x-ray machine port..
- HTWS-C-type eddy current fl..
- ACCUTRAK feedback signal sw..
- High-low pressure foundry _..
- ELS-6000 Industrial HD X-ra..
- ELS-50 Portable X-ray detec..
- ELS-8000 HD X-ray detection..
- ELS-6000 Industrial HD X-ra..
- ELS-3000 HD Industrial X-ra..
- Digital ultrasonic flaw det..
- Shijiazhuang, the price of ..
- Low pressure foundry procur..
- ELS-100 portable x-ray mach..
- Non-destructive flaw is whe..
- Weld portable ultrasonic fl..
- Non-destructive testing ins..