Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Supply two vacuum tank

Supply two vacuum tank
Supply two vacuum tank
Supply two vacuum tank

Larger photo of automa dispenser

Company:Beijing Jingheng Huatai Engineering Ltd.
Information Name: Supply two vacuum tank
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Secondary pressure tank, while the cut-off valve box and integrated pipeline pressure off function, reduced pipeline pressure purpose is to control the pressure in a certain range, such as the oxygen pressure control for the ward at 0.3 to about 0.5Mpa, the pressure for the hyperbaric oxygen chamber controlled at about 0.6 ~ 0.8Mpa, the pressure output from the bus or liquid oxygen tank is generally about 0.8 ~ 1.0Mpa. Set a secondary decompression device in the gas area of ??use, you can also play the role of a buffer line pressure, reduce the impact on the patient, reduce application risk. Suction system and AGSS system does not require decompression, and oxygen, compressed air, nitrous oxide and other medical gases generally need to set up a secondary decompression device in the pipeline. As of function the main achievement of the pipe off and on, I realize linear ball off control of the pipeline. General linear valve is installed in front of the reducer with reducer series in the pipeline. In order to prevent or linear regulator valve failure affect the use of gas, usually in the gas pipeline also need to install branches (negative pressure systems and AGSS system does not slip), once the regulator or pressure reducer series The linear valve fails, open linear ball support on the road, in order to ensure a continuous supply of the gas can. The aim is to line pressure control within a certain pressure range, such as the control unit for oxygen pressure of about 0.3 ~ 0.5Mpa, it will be used to control the pressure hyperbaric oxygen chamber is about 0.6 ~ 0.8Mpa, and from the bus pressure liquid oxygen tank platoon or output is generally about 0.8 ~ 1.0Mpa. Set a secondary decompression device in the gas area of ??use, you can also play the role of a buffer line pressure, reduce the impact on the patient, reduce application risk. Suction system and AGSS system does not require decompression, and oxygen, compressed air, nitrous oxide and other medical gases generally need to set up a secondary decompression device in the pipeline. As of function the main achievement of the pipe off and on, I realize linear ball off control of the pipeline. General linear valve is installed in front of the reducer with reducer series in the pipeline. In order to prevent or linear regulator valve failure affect the use of gas, usually in the gas pipeline also need to install branches (negative pressure systems and AGSS system does not slip), once the regulator or pressure reducer series The linear valve fails, open linear ball support on the road, in order to ensure a continuous supply of the gas can. 
Contact Detail
Company Name: Beijing Jingheng Huatai Engineering Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. CHEN()
Telephone Number: 010-67988818
Company Address: Daxing, , Beijing, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450