Coating thickness gauge thickness of the detector PCB coating thickness measurement
Coating thickness gauge thickness of the detector PCB coating thickness measurement
E3 is a universal energy dispersive X-ray fluorescence spectrometer (EDXRF); its core components imported by the United States, the software algorithm used by the US EDXRF cutting-edge technology, the instrument has the authority of a third-party testing organization reporting standard sample; using small spot design, large small PCB board test points precisely positioned to avoid interfering materials; openness adjustable sample stage to deal with a variety of large PCB board, no split can be directly tested. ● Dimensions: 360 mm x 600mm x 385 mm (length x width x height) ● sample compartment size: 360mm × 400mm x160 (length x width x height, height can be customized) ● Instrument Weight: 50kg ● Power supply: AC220V / 50Hz ● Maximum power: 330W ● Working temperature: 15-30 ℃ ● Relative humidity: ≤85%, no condensation detector ● Type: X123 detectors (imported high-performance electric refrigeration semiconductor detector) ● Be window thickness: 1mil ● crystal area: 25mm2 ● The best resolution: 145eV ● Signal Processing System: DP5 X-ray tube ● Voltage: 0-50v ● Maximum current; 2mA ● Maximum Power: 50W ● Target: Mo ● Be window thickness: 0.2mm ● life: more than 2w hour high voltage power supply ● Output voltage: 0-50Kv ● filament current 0-2mA ● Maximum power: 50w ● ripple factor: 0.1% (pp value) ● 8 小时 Stability: 0.05% Camera ● Focus: Micro Focal length ● driver: free driver ● pixels: 500 million pixels collimator, filter ● system: fast disassembly collimators filter system ● Materials: a variety of materials collimator ● spot: spot size Φ0.2mm, Φ1.0mm, Φ2.0mm, Φ4.0mm optional ● combination: a variety of filters (software automatically switches), a combination of cross laser collimator head ● spot shape: crosshairs ● Output Wavelength: Red 650nm ● optical lens : glass lens ● Size: Φ10 × 30mm ● divergence angle: 0.1-2mrad ● Operating Voltage: DC 5V ● output power: <5mW ● Working temperature: -10 ~ 50 ℃ ● Storage temperature: -40 ~ 85 ℃ other accessories ● Switch Power: imported high-performance switching power supply cooling fan ●: import low-noise, high winds fan
Contact Detail
Company Name: | Shenzhen seedlings Analytical Instruments Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Xu Lingjie(Sales Manager) |
Telephone Number: | 0755-86219363-627 |
Company Address: | 27, 2nd Floor, Nantou, Nanshan District Road crossing Heng Industrial Park, Shenzhen, Shenzhen City, Guangdong, China |
Zip/Postal Code: | 518052 |
Find More Related Products
- Supply of blue-peng speed o..
- PC film thickness MCH-2001J
- Chengdu to Yushu logistics ..
- Jiangnan thickness gauge ul..
- Coating thickness gauge how..
- 2015 ultrasonic thickness m..
- Oil tank wall thickness gau..
- Pvc plastic pipe wall thick..
- Supply of the metal thickne..
- Ultrasonic Thickness high t..
- Ultrasonic Thickness NDT320..
- Ultrasonic Thickness NDT650..
- Prices film thickness using..
- Thickness Ultrasonic Thickn..
- Huaguang thermal CTP plate ..
- Transmittance tester, east ..
- Through the coating thickne..
- Extension Section licensing..
- Plated copper base enamel e..
- KSHW-A type infrared film t..
- Iron-based coating thicknes..