2015 ultrasonic thickness measurement of metal thickness of the glass thickness NDT310

2015 ultrasonic thickness measurement of metal thickness of the glass thickness NDT310
2015 ultrasonic thickness measurement of metal thickness of the glass thickness NDT310
2015 ultrasonic thickness measurement of metal thickness of the glass thickness NDT310

Larger photo of automa dispenser

Company:Beijing Kai Dake Instrument Technology Co., Ltd.
Information Name: 2015 ultrasonic thickness measurement of metal thickness of the glass thickness NDT310
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Ultrasonic thickness measurement NDT310 metal (such as steel, cast iron, aluminum, copper, etc.), plastics, ceramics, glass, fiber glass and any other good ultrasonic wave conductor, has a powerful measurement capabilities and advanced data acquisition and output capabilities for for measuring internal corrosion or other metal structures corroded pipes, casing, pressure vessels, steel, etc., can also measure ceramics, plastics, glass and other good ultrasonic wave conductor materials. Unique features: a new generation of intelligent ultrasonic thickness gauge, using the latest high-performance, low-power microprocessor technology, accuracy of 0.1 / 0.01 adjustable bright LED LCD Ultrasonic Thickness NDT310 main purposes: * can be measured thickness of the metal, glass, ceramics and other materials, and the speed of sound material widely used anti-measurement * sheet, pipe wall thickness, vessel wall thickness of boiler, various pipes and pressure vessels for thickness measurement, monitoring them the course of the degree of corrosion thinning 凯达科 after Beijing Instrument Technology Co., Ltd. is a professional manufacturer of ultrasonic thickness gauge, good service, welcome to inquire, and another handheld roughness tester, portable hardness tester, coating thickness gauge, ultrasonic flaw detector and other nondestructive testing equipment for the king to choose from. Phone: 010-8267-5282 Ultrasonic Thickness NDT310 Features: * Can be equipped with a variety of different frequencies, different wafer sizes duals use * has probe zero calibration, two-point calibration function, the system can automatically correct the error * known thickness can counter measure the speed of sound, in order to improve the measurement accuracy with coupling state prompts * * have LED backlit display for easy use in dimly lit environments * A remaining charge indicator, real-time display remaining battery charge * with auto sleep, auto shutdown and other power-saving features * Compact, high portability, reliability, suitable for harsh operating environment, anti-vibration, shock and electromagnetic interference Ultrasonic Thickness NDT310 technical parameters: Measuring range 0.75 ~ 300mm (probe decision) Resolution 0.1mm / 0.01mm optional metric and imperial units of measurement selectable measurement accuracy ± (0.5% H + 0.04) mm H is the actual thickness of the measured speed of sound regulation of 1000 ~ 9999 m / s for storing data values ??stored 500 data read, view and delete the minimum thickness values ??having minimum thickness capture capability capture capability surface temperature -10 ~ 60 ℃ measurement cycle single-point measurement 4 times / sec, scan mode 20 times / sec Pipe measurement limit Φ20 mm × 3.0 mm (5Mhz probe); Φ15 mm × 2.0 mm (7Mhz probe) Indication error does not exceed ± 0.1 mm calibration 4.0 mm (steel) Probe specifications Φ6 mm (optional) Φ10 mm (optional) Φ12 mm (optional) Power supply AA-size alkaline batteries 1.5V ( 2) operating time up to 250 hours of continuous operation (without backlight) Dimensions 150 × 74 × 32 mm Weight 238g Standard configuration NDT310 host section (non-aviation 5MHz probe, 4.0 mm steel calibration block, coupling agents, battery 2) Optional accessories 2MHz (coarse grain probe), 7MHz (micro-diameter probe), 5MHz (temperature probe) Optional probe parameters: Name Type Frequency (MHZ) probe diameter measuring range Minimum diameter characterization standard probe N05 5 10mm 1.2mm ~ 230mm (steel) Φ20mmX3mm use at room temperature (<60 ℃) N05 / 90 coarse grain probe N02 2 22mm 3.0-300.0mm (steel) 20mm coarse-grained cast iron and other materials used in measuring 5.0-40.0mm (cast iron) micro-diameter probe N07 7 6mm 0.75mm ~ 80mm (steel) Φ15mmX2mm measurements for thin-wall and small arc, the temperature probe HT5 5 14mm 3.0mm ~ 200mm (steel) 30mm material for a temperature less than 400 ℃ measurement service: the user presses the "Use Manual "under normal operating conditions, the Company products replacement within three months, two years free maintenance (but wearing consumable parts except probe sensor cable), and is responsible for the product life-long maintenance. 
Contact Detail
Company Name: Beijing Kai Dake Instrument Technology Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Cheng Lu Yao(Sales)
Telephone Number: 010-82675282
Company Address: Haidian District, Beijing Building Materials Cheng Yuan Cheng Road, Building 3, 504, Beijing, Beijing, China
Zip/Postal Code: 100096