Battery high and low temperature test box manufacturing
Battery high and low temperature test box manufacturing
Paddy ASHDOWN Lai production of battery high and low temperature test chamber, also known as high-temperature cycling chamber design aesthetic appearance, reasonable installation location of each component, electrostatic spraying color to meet customer requirements for laboratory supporting the overall. Japanese original high-precision programmable temperature controller, 7-inch color touch-screen operation, Chinese / English LCD with a 10M / 100M Ethernet interfaces, were presented operating software. Walk-in high and low box technical specifications: www.asliyq.cn 1. temperature cycling chamber system must be maintained by hand operation. Strict compliance with system rules, to prevent others illegal operating system. 2. The file system should be established to facilitate system maintenance and repair. Use file should record the starting and ending time for each system operation (date), the type of test, the ambient temperature; when the system fails to deal with failure phenomenon as described in detail; the system maintenance, repair content should also be possible detailed records. 3. The system downtime not, would affect the effective life of the system, so the system to boot at least once every 10 days to run; do not repeatedly make the system run a stop in a short time, the number of starts per hour should be less than 5 times, Every time - stop time interval is not less than 3rain; do not open the door system at low temperatures, in order to prevent damage to the door sealing tape. The monthly once the main power switch (leakage crowbar) action tests to ensure that this switch is in the ability to meet the load as the leakage is under the protection. Specific steps, first make sure the main power switch to "ON", ie the system is powered, then press the test button. If leakage circuit breaker switch lever down to is this feature to work. 5. GFCI leakage overload and short circuit protection feature by the factory setting, in use, can not be adjusted, so as not to affect performance;. GFCI because after the short circuit is opened, the contacts need to check if the main contact wear serious or When there is a pit, the need for maintenance. 6. In order to ensure that the cooling water supply to normal and clean, about once every 30 days to clean the refrigerator cooling water filters, cleaning a water cooling towers if local air quality is poor, high dust content in the air, generally should be cleaned about 7 days cooling tower reservoir. 7. Test product placement within the system from air-conditioning suction channels. Air vents should be a certain distance, so as not to impede the flow of air. 8. once a year, with a vacuum cleaner to remove the power distribution room house dust and water circuits. Once a month, dry with a dry cloth to clean the water tray water chillers. Battery high and low temperature test box Features: www.gdwcsx.com 1. System main box, use should be protected, not by the strong collision or blunt weapon. 2. With a very wide temperature control range. 3. Over-temperature protection action test. The over-temperature protection temperature is set to a lower temperature than the cabinet, if there E0.0 alarm and buzzer sound to indicate that it is functioning properly. After completion of the test, you should re-setting the temperature protection is appropriately set, it may cause undue suspended. 4. Imported refrigeration compressors, refrigeration uses the latest cold end output control, compared with the traditional balance of hot and cold, greatly save energy, reduce the cost of customers. Walk-in high and low box rules: 1. In order to avoid a walk-in high and low box malfunction occurs, provide power supply within the rated voltage range. 2. To prevent electric shock or malfunction and failure, before the end of the installation and wiring, please do not turn on the power. 3. This product is not explosion-proof products, please do not use walk-in high and low box where there is flammable or explosive gases bad environment. 4. Instrument work, please try not to open the chamber door open may cause the operator to cause burns at a high temperature, open staff might cause frostbite at low temperatures and can cause evaporator freeze, affect the cooling effect. If you must open the chamber door, be sure to do a good job related to protection work. 5. Never attempt to disassemble. Processing. Alteration or repair walk-in high and low box, or there will be an exception action. Risk of electric shock or fire. 6. vents the body needs to keep them open, in order to avoid failure, abnormal movements, reduced life expectancy. 7. When the machine out of the box if found damaged or deformed, do not use electricity. 8. Do not allow dust machine. Thread. Iron or other items into the installation settings, otherwise malfunction or failure may occur. 9. The wiring must be correct, it must be grounded. Improper grounding may cause electric shock. Malfunction accident. Display is not normal or larger measuring errors. 10. The regular inspection terminal screws and holder, do not use in case of loosening. 11. During instrument operation, the power supply into the power terminal cover plate must be installed in the terminal to prevent electric shock. 12. The meter in operation, modification setting signal output start before stopping and other operations, should fully consider the safety, erroneous instruction may result in damage or malfunction. 13. Use a dry cloth to wipe the instrument, do not use alcohol, gasoline or other organic solvents, do not put the water splashed on the instrument, if the instrument is immersed in water, please stop using it immediately, otherwise there is leakage danger of electric shock or fire. 14. The instrument has a certain internal parts lifetime, for the continued safe use of the instrument, perform maintenance and repair work on a regular basis. When disposing of the product, according to industrial waste. www.gdwcsx.com battery high and low temperature test box uses Aisi Lai temperature cycling chamber (13,532,571,289) is mainly aimed at electrician electronic products, as well as their original devices, and other materials at high temperature, low temperature, humidity and cycling Under the environment storage, transportation, use of adaptive testing of. High temperature cycling chamber is mainly used for products in accordance with national standards or user-defined requirements, at low temperature, high temperature, high humidity and high temperature cycling conditions, physical and other relevant characteristics of the product environmental simulation test, test , through testing, to determine the performance of the product, it is still able to meet predetermined requirements in order for the product design, improvement, identification and factory inspection use. Battery high and low temperature test chamber price http://www.gdwcsx.com/HL/17.html high and low temperature http://www.gdwcsx.com/HL/19.html -40 ℃ high temperature test box http: / /www.gdwcsx.com/HL/22.html Tianjin high temperature aging test machine http://www.gdwcsx.com/HL/24.html monitor temperature cycling chamber http://www.gdwcsx.com/HL /26.html large volume walk-in high and low temperature test chamber http://www.gdwcsx.com/HL/28.html high and low temperature heat chamber standard http://www.gdwcsx.com/HL/27. html
Contact Detail
Company Name: | City Aisi Li detection equipment Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Miss Chang(Assistant Sales Manager) |
Telephone Number: | 0769-22851843 0769-22851841 |
Company Address: | Dongguan Dongcheng Lixin Jinhui Industrial Park, Dongguan City, Guangdong, China |
Zip/Postal Code: | 523002 |
Find More Related Products
- UV ultraviolet aging test e..
- What high and low temperatu..
- Film impact tester technica..
- Style wings drop test equip..
- The UV weathering chamber t..
- Nano spray coatings, nano-s..
- Tianjin on Tairong laborato..
- Ozone aging test equipment ..
- Heat Treatment
- QPQ metal surface treatment..
- QPQ heat treatment
- Mold, tool, cutter body, ro..
- QPQ carbonitriding, QPQ nit..
- QPQ surface treatment
- Yellowstone Million and wat..
- Ferrous metal surface treat..
- Supply Tengzhou qpq heat tr..
- QPQ ferrous metal surface t..
- Metal surface treatment
- QPQ heat treatment surface ..
- qpq Surface Treatment Techn..