Bank vault Access Control System
Bank vault Access Control System
Product Overview: Key financial institutions belonging to the state security unit, which has a scale of diversity, many important facilities, access to staff complex, involving a wide field of management features, which serves as the main currency in circulation place in today's society, an important part of the operation of the national economy, its unique features and advanced technology widely used in domestic industries, the bank vaults are placed directly on a lot of cash, securities and valuables vital departments, security is essential. At present, domestic banks against crime tends to go up, crime means and methods gradually diversified, violence, intelligence; while the bank's internal crime are constantly upgrading concealed, how to avoid the risk of loopholes in the system to bring, how to fully strengthening and updating existing bank security systems, in order to adapt the banking system to transition and business development has become imminent. Shou remote remote access management database system for treasury control, event notification, alarm processing, the use of advanced biometric technology to solve the traditional key easy to copy, combined with video technology to solve safety problems caused by the non-real-time monitoring. The whole system in order to prevent theft treasury robbed, avoid system defects, optimize the integration of resources and reduce the administrative leader pressure, comprehensive prevention technology to provide a complete solution. Effectively reducing the criminals of opportunity, most likely reduce the incidence of the financial unit cases. RF card access control each channel (here mainly vault door) and out of management for centralized management and distributed processing, we can use the sensor card as treasury maintenance staff and patrol officers out of treasury certificates, treasury access channel can be generated by the computer access to records of security reports, and through access to environmental monitoring devices to access linked devices transmit real-time alarm information to ensure the stable operation of the treasury. Features: ? Two front-end recognition interfaces: Supports Wiegand-26/34 format card reader and fingerprint, iris biometric systems large capacity relay output: DC30V NC: 2A NO: 2 A · Mass Storage: offline management 30,000 users, offline storage 100 000 event records · N + 1 door model: "N + 1" is a combination of permissions, permission from the N group depicting a staff consisting of N local authentication, plus a remote monitoring center management Certified open; you can also pre-set permissions for a certain leadership in all communication interruption, the management center can not be real-time monitoring of the special circumstances, leading to the site instead of an authority to exercise Flexible remote monitoring center managers, reliable Alarm function: a door open alarm for no reason, the delay did not shut the door open alarm function; with 5 groups of alarm telephone numbers; alarm information can be sent directly to the manager or the phone alarm personnel, supports user-defined SMS alarm message content. Support duress alarm function; support alarm handling, pretreatment. With 4 wired zones, support for custom each input and output functions name; flexible system configuration can be adapted to various environments Rich time management, can be set 16 kinds of common time zone and two special time zone Dual network dual pending communications, seamless switching: dual network refers to the TCP / IP communications network and GSM communications network, the system simultaneously with these two means of communication, the use of TCP / IP communication system, GSM communication can be used as an alternate means, when TCP / IP network is interrupted unexpectedly, the system automatically switches to the GSM communications work-rich, secure operator logs management: operational support division operator function, front-end equipment, personnel and other administrative privileges, restrictions; support operator password, fingerprint, password or fingerprint, password + fingerprint, log; support operator Sign Dayparting; support operator logs directly into the default user interface * Powerful custom linkage function; user-defined input and output according to demand linkage between the interface between the linkage and linkage time frequency; support user for each input and output interfaces for custom name · convenient and reliable way to arm and disarm: You can arm the Administration Center, door, phone, etc., disarm · Professional Security: Each Stand-have anti-shorting, anti-cut line function; support normal, 24-hour zones, delay, delay waiting for other zone types: Support Zone Bypass Support door sensor, card, button, cell phone timing, etc. for cloth, disarm Rich zone type: Support 24h, general, and other types of delay zone, zone name can be user-defined Flexible mobile remote configuration, control function: users can phone on the front-end machine for cloth disarm, zone bypass, the center door and other configuration, control operation * Optional Zone Bypass, select zone type Powerful video features: support for multi-window real-time preview, PTZ control, video parameter settings; support normal event-triggered camera and video; support alarm event triggered camera and video; supports manual capture, video; support local playback and remote playback; access real-time monitoring front-end machine recording, alarm recording, record arming, DVR alarm information; DVR supports viewing logs, etc. · Support Manager mobile remote arm and disarm, remote door opening ? System health monitoring: real-time alarm information to the front end of the machine, arm and disarm status, power status, Ethernet monitoring online information; support for offline detection controller performance: controller uses the new system architecture, low-power, high-performance MCU serves as the control center large capacity FLASH memory, no battery power, data storage for 20 years without losing the input and output optical isolation, effectively adapt to different environments supply terminal overvoltage, overcurrent, backpressure protection, safe and reliable under the circumstances to protect the user misuse the power supply controller to the read head side overcurrent, overvoltage, reverse voltage protection, reliable protection of the read head in exceptional cases safety relay outputs have overvoltage protection, effective protection of abnormally high pressure Security at power locks, alarm devices and other peripheral devices can be connected to two reader (compatible with HID, Motorola and other brands of standard Wiegand-26/34 format card reader) and fingerprint, biometric systems can be customized input linkage between the output interface between the linkage and linkage time the number of applications can be carried out by patrol controller management software for each input and output interface custom name and alarm information powerful self-monitoring capability, tamper alarm, 220V out electric alarm, backup battery low voltage alarm hardware anti-interference ability, high reliability. Built-in hardware watchdog, to prevent crashes; all input and output terminals are provided with a voltage dynamic protection, all relay output terminals are with momentary voltage protection; the power input over-current, over-voltage, reverse voltage protection; a communication port has an instant Overvoltage Support 4 zone inputs can be customized, expandable up to 12 channels. Each zone can be separate arm / disarm. It can be connected with a variety of security, fire and emergency switch probe. All zone inputs support the anti-short circuit function, to avoid vandalism, recording multiple alarm events (door open delay, door open for no reason, duress, tamper, power failure, etc.) Specifications: Panels Size: 160X125 (mm) Control box dimensions: 500X400X100 (mm) Power Requirements: DC12V (± 10%) 500mA Working Environment: Temperature -40 ℃ - + 70 ℃ Humidity 10% -90% RH, non-condensing Communication: TCP / IP, SMS, RS485, GPRS (optional) a variety of communication main control panel status indication: The main control board has power (red), communications (green), relay (red, located next to the relay) Operation indicator Relay output: 4 Group 12V / 3A relay (NO, NC) protection against interference: All input and output terminals are provided with a voltage dynamic protection, all relay output terminals are with momentary voltage protection; the power input over-current, over-voltage, reverse voltage protection; communication Ports have instant overvoltage protection
Contact Detail
Company Name: | Shenzhen Cheung Hengwei Technology Co., Ltd., Wuhan Off.. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Yuan Bin(Sales Manager) |
Telephone Number: | 027-87789211 027-15014074-364 |
Company Address: | Bao'an District of Shenzhen City, East China, Central Road Jing Xuan Long Industrial Zone 12 on the fourth floor, Shenzhen City, Hubei, China |
Zip/Postal Code: |