Mine air conditioning heating unit _ Watson heating units Figure _ mine picture
Mine air conditioning heating unit _ Watson heating units Figure _ mine picture
Heating unit known mine air heating units, industrial hot air. It is designed for a heating and ventilation equipment industrial and mining development. It is a conventional air heater upgrading of products. Air heating unit components: unit uses the frame plate structure: the panels, aluminum alloy rod qualities, steel-aluminum heater, low noise axial fans, inlet air filter, the air control valve, simple cabinet, black base and so on. kjz air heating units - heating units mine - mine hot air units - mine fan heater rod prices for the aluminum (70 / 70mm), the thickness of 2.5mm, internal encryption seals. Panel color steel (basket or white) Thickness 0.5mm, the intermediate insulation material 50mm polyurethane insulation boards. 10 # channel steel base is welded, installation does not require anchor bolts. Each unit must be configured separately control system, independent control of any single failure should not affect the safe operation of the other units. Unit requires mechatronic design, electrical parts configuring the drive, the automatic control system can automatically start and stop and run according to outdoor climatic conditions and the set value, true unattended. The control system uses a two-way control (1) air volume control (inverter) (2) intelligent flow control valve. Air heating unit requires cooling area, high heat transfer efficiency, air and quantity, air temperature and air volume can be automatically controlled, energy saving, easy installation. Texas Watson air-conditioning plant specializing in the production and processing of mine air heating unit, this mine is underground heating heating unit for air heater. Air heating unit is based on the mine in order to prevent freezing in winter wellbore into the wind, we must need to supply warm air underground, the development of an efficient air heating equipment. Mine heating unit in an efficient finned tube heat exchanger components as used CNC equipment around the film tightly wrapped around the aluminum pipe outer wall, the use of efficient thermal conductivity of aluminum, making rapid and uniform heat transfer to the air. Mine air heater is used for a variety of mineral industry-specific equipment, which is set in the outer wellhead master, auxiliary shaft room, fresh air through the winter well wellhead heating air heating unit, added into the underground wellhead so cold northern cold the air is heated to a temperature above the freezing point, to avoid the wellhead safety hazard and cause icing problems. Mine air heating unit sub-type hot water and steam. By the air heater, fan housing, dampers and other components, fan into axial fans, centrifugal fans are two, the user can be selected. Heating unit known mine air heating units, industrial hot air. It is designed for a heating and ventilation equipment industrial and mining development. It is a conventional air heater upgrading of products. Underground mine air heating unit is heating for air heater. Mines heating unit is based on the mine in order to prevent freezing in winter wellbore into the wind, we must need to supply warm air underground, the development of an efficient air heating equipment. Mine air heating unit for wellhead mine air heating, can be used for temperature control in large industrial building and material drying. As efficient finned tube heat exchanger components, the use of CNC equipment around the film tightly wrapped around the aluminum pipe outer wall, the use of efficient thermal conductivity of aluminum, making rapid and uniform heat transfer to the air. Industrial hot air unit is used in a variety of mineral industry-specific equipment, which is set in the outer wellhead master, auxiliary shaft room, fresh air through the winter well wellhead heating air heating unit, added into the underground wellhead so cold northern cold air heated to a temperature above the freezing point, to avoid the wellhead freezing problems and cause safety problems. Heater unit uses the frame plate structure: the panels, aluminum alloy rod qualities, steel-aluminum heater, low noise axial fans, inlet air filter, the air control valve, simple cabinet, black base and other components. Aluminum alloy rod (70 / 70mm), thickness of 2.5mm, the encryption seals. Panel color steel (basket or white) Thickness 0.5mm, the intermediate insulation material 50mm polyurethane insulation boards. 10 # channel steel base is welded, installation does not require anchor bolts.
Contact Detail
Company Name: | Texas Watson air-conditioning plant |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Su Guozheng(Sales Manager) |
Telephone Number: | 0534-5087808 534-6351260 |
Company Address: | Dezhou Wu Lu right Tuen County Industrial Park, No. 188, Germany City, Shandong Province, China |
Zip/Postal Code: | 253000 |
Find More Related Products
- Watson-conditioned FIG _ _ ..
- Which radiator radiator fin..
- Sky HOT ST fiberglass hospi..
- Pit heating unit where the ..
- Watson-conditioned FIG hot ..
- Watson air conditioning hea..
- Watson air conditioning fan..
- Production cooler cooler ai..
- Mine heating heaters, heate..
- Vapor air curtain air curta..
- Steel Aluminium composite f..
- Watson has been certified a..
- Watson has been certified a..
- Manufacturers for central a..
- Watson-conditioned Figure f..
- Vapor finned radiator facto..
- Watson Quality Assurance Ce..
- srz Heaters Heaters Watson ..
- Hot water air curtain air c..
- Wholesale air-conditioning ..