Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Plug-in electromagnetic flowmeter

Plug-in electromagnetic flowmeter
Plug-in electromagnetic flowmeter
Plug-in electromagnetic flowmeter

Larger photo of automa dispenser

Company:Dalian Suo Nika Instrument Co., Ltd.
Information Name: Plug-in electromagnetic flowmeter
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Products: plug-in electromagnetic flowmeter: insertion electromagnetic flowmeter measurement principle is Faraday's law of electromagnetic induction, insertion electromagnetic flowmeter sensor main components: the measuring tube, electrodes, excitation coil, core and yoke housing. Plug-in electromagnetic flowmeter for measuring in closed conduits conductive liquid and slurry volume flow. Including highly corrosive liquid acid, alkali, salt. Plug-in electromagnetic flowmeter has been widely used in petroleum, chemical, metallurgy, textile, food, pharmaceutical, paper and other industries as well as environmental protection, municipal administration, water conservancy construction. Plug-in electromagnetic flowmeter Features: 1, measurement not affected by fluid density, viscosity, temperature, pressure and electrical conductivity changes; 2, unimpeded flow of parts within the measuring tube, no pressure loss, lower straight pipe requirements; 3, series Nominal diameter DN15 ~ DN3000. Sensor lining and electrode materials have a variety of options; 4, the converter uses a novel excitation mode, low power consumption, zero stability and accuracy. Flow range of up to 1500: 1; 5, the converter can be composed of a body or a separate sensor type; 6, the converter uses 16-bit high-performance microprocessors, 2x16LCD display, convenient parameter setting, programming and reliable; 7, traffic bidirectional meter measurement system, built-in three Totalizer: forward total, reverse total and the total amount of the difference; can be displayed. Zhuang, regurgitation, and a variety of output: current, pulse, digital communications; 8, the converter using surface mount technology (SMT), a self-test and self-diagnostic function insertion electromagnetic flowmeter consists of insertion electromagnetic flow sensor (referred to as sensor) and electromagnetic flow converter (abbreviated converter) supporting component (the meter). Pipe is used to measure a variety of conductive liquid volume flow meter. Used to measure the conductivity of the fluid flow of water, iron and steel, petroleum, chemical, power, industrial, water and other sectors, also measuring acid, alkali, salt and other corrosive conductive liquid. Plug-in electromagnetic flowmeter features: corrosion-resistant stainless steel material ABS simple full-mold probe, firm structure, no moving parts, long service life: reliable measurement, anti-jamming; small size, light weight, easy installation, low maintenance ; measuring range, the measurement is not affected by temperature, density, pressure, viscosity, electrical conductivity and other changes; the pressure loss is zero; in the case of continuous flow can be installed, disassembled for overhaul to bring the convenience of users. Manufacturing costs and installation costs are lower than the average of electromagnetic flowmeters, especially for medium and large diameter pipe flow measurement. Key performance indicators: flow rate measuring range: (0.05-10) m / s measurement pipe diameter: DN (100-3000) mm Accuracy: 1.0 Working Pressure: <1.6MPa Medium temperature: 0-80 ℃ Power Consumption: <20VA Installation: The sensor is installed upstream of the straight pipe of not less than 5D (D: diameter), downstream straight pipe of not less than 2D plug-in electromagnetic flowmeter installation: (a) Vertical installation and during sensor into the pipe and the pipe section diameter vertical angle of less than 5 °, suitable for measuring the vibration pipe cleaning media. (B) Upright, axis angle for the pipe axis and its sensor is 45 °, for large diameter and the measurement of liquid flow measurement medium contains other impurities, the installation of water resistance is small, not wrapped around the hanging. Insertion electromagnetic flow sensor insertion point, there are two ways: First, to the central axis of the insert for the pipe, the second is inserted into the pipe wall to 0.25D in the pipeline. Installation instrument insertion electromagnetic flowmeter 1, clean up the test tube installed base of slag and burrs. 2. Turn off the upstream flow control valve or low pressure water supply. 3, the DN50 valve mounted to the mounting base. Note ball up the sky chamber, checking whether the valve fully open fully closed, the pressing threaded mount, compression nut and rubber seal mounted on the valve. Loosen the nut. Insert the sensor into the test rod is inserted into the pipe through ball, but should pay attention to the sign post pointing to the direction sensor should be consistent and fluid flow. >> The above article: Plug-in electromagnetic flowmeter. Dalian Suo Nika Instrument Co., Ltd. production and sales, detailed consultation Dalian Suo Nika sales. 
Contact Detail
Company Name: Dalian Suo Nika Instrument Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Zheng Liming(Sales Manager)
Telephone Number: 0411-87305712
Company Address: Liaohe River Road No. 155, , Liaoning Province, China
Zip/Postal Code: 116600
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450