Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Rainbow Run precision instrument, roundness, cylindrical instrument, profiler

Rainbow Run precision instrument, roundness, cylindrical instrument, profiler
Rainbow Run precision instrument, roundness, cylindrical instrument, profiler
Rainbow Run precision instrument, roundness, cylindrical instrument, profiler

Larger photo of automa dispenser

Company:Hong Kong Chang Hui Automation Instrumentation Co., Ltd.
Information Name: Rainbow Run precision instrument, roundness, cylindrical instrument, profiler
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Using the subject liquid, gas, vapor pressure measurement, the liquid level measurement. Features ● High accuracy, good stability. ● wire operation, 4 ~ 20mA signal output. ● sensitive components and circuit boards are all-solid structure, strong vibration. ● anti-interference ability, good temperature stability. ● Explosion-proof housing structure, all-weather use. ● has the best corrosion resistance, to ensure the best cost-effective antiseptic. ● compact structure, simple and reasonable, no support, no horizontal installation can be directly installed in the pipeline at any position. K1 type K2 type works medium pressure directly on the ceramic sheet, the measurement diaphragm shifted. Normal pressure diaphragm offset 0.025mm, overpressure diaphragm offset only 0.1mm. In this case, the measuring diaphragm attached to the ceramic brackets, to avoid damage. Capacitance diaphragm displacement produced by the electronic components directly connected to detection, amplification and conversion to standard signal output. Measuring system wiring diagram in the system circuit must be shielded signal cable, and grounded. Measurement system diagram (4 ~ 20mA) Intrinsically Safe Pressure Transmitters HR-K intrinsically safe pressure transmitter with intrinsically safe circuits for explosion hazardous areas, explosion-proof grade Exd ⅡBT4, technical performance indicators and common type pressure transmitter the same device. In the system circuit must be shielded signal cable, and grounded. Intrinsically safe measuring system diagram (4 ~ 20mA) Mounting HR-K series pressure transmitter usually direct pipeline installation, install a valve, easy installation, commissioning and maintenance. When the medium temperature is higher than 85 ℃ will need to install a certain length of impulse piping for cooling medium, otherwise it will cause damage to the transmitter measurements are not allowed to even. Direct pipeline installation accessories user can be based on fixed and fixed-site environmental requirements, with a wall fitting or pipe fittings. Wall fixing screw M5 2- B3 1- M8 expansion screw fixing B1 vertical pipe rack frame fixed horizontal tube type B Dimensions Dimensions K1 - K2 technical performance and Dimensions Specifications Power: 24V · DC; no load transducer It can work in 12V · DC, max 40V · DC. Load characteristics: Output signal: 4 ~ 20mA load resistance R and the power supply voltage V relationship: R≤50 (V-12) Ω span and zero: Open the terminal side of the rear cover is continuously adjustable, zero adjustment range is the maximum range of ± 5%, the span adjustment range of 40% to 100% of the maximum range. Temperature range: Ambient temperature -40 ℃ ~ 80 ℃ medium temperature -40 ℃ ~ 85 ℃ Storage Temperature -40 ℃ ~ 85 ℃ Overpressure limit: see table relative humidity range: 0 to 95%. Damping: 0.5S. Weight: 0.85kg, accuracy: ± 0.2%, including linear, variation and repetitive composite error. Stability: maximum range of ± 0.1% (1 in) temperature: at -20 ~ 80 ℃, variation ± 0.15% / 10 ℃. Overpressure Impact: pressure plus overpressure within the limits, the error is ± 0.25% of maximum range. The maximum load resistance Vibration: frequency 15Hz on any axis, the maximum error is less than ± 0.01% of range / g. Power effect: less than the output range of 0.01% / V. Load Impact: If the input voltage to meet the load characteristic, no loading effects. Mounting position Impact: None. HR-K pressure transmitter type spectrum table diaphragm material HR-K1 ceramic capacitors HR-K2 diffused silicon | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Transmitter Type SI standard intrinsically safe ExibⅡBT4 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Process connection material 19 Stainless steel 316L special requirements | | | | | | | | | | | | | | | | | | | | | | | | | | | | | process connections RGMAY external thread G 1 / 2 external thread M 20 × 1.5 external thread G 1/2 1/2 NPT male thread holes Particular requirements | | | | | | | | | | | | | | | | | | | | | | | seal material 1F 2F 9F nitrile rubber fluorine rubber mold special requirements | | | | | | | | | | | | | | | | | | | signal output 2 4 ~ 20mA two-wire | | | | | | | | | | | | | | | | Type of housing ABY IP65 aluminum housing without the instructions of aluminum housing with on-site instruction IP65 (analog indicator) Special requirements | | | | | | | | | | | | Accuracy class 259 0.2 0.5 Special requirements | | | | | | | | measurement range (see standard range table) Y nonstandard range | | | | | | | HR-K1 S 1 G 1F 2 A 5 F2 standard range meter measuring range Code Span adjustment range overload 0 ~ 4KPa D1 0.7 ~ 7KPa 0.6 0 ~ 6KPa D2 0.7 ~ 7KPa 0.6 0 ~ 10KPa D3 1.0 ~ 10KPa 0.6 0 ~ 16KPa D4 10.0 ~ 20KPa 0.6 0 ~ 20KPa D5 10.0 ~ 20KPa 0.6 0 ~ 25KPa D6 12.0 ~ 30KPa 0.6 0 ~ 40KPa D7 12.0 ~ 40KPa 0.6 0 ~ 60KPa D8 20.0 ~ 60KPa 0.6 0 ~ 100KPa E1 30.0 ~ 100KPa 1.0 0 ~ 160KPa E2 60.0 ~ 200KPa 1.0 0 ~ 200KPa E3 60.0 ~ 200KPa 1.0 0 ~ 250KPa E4 120.0 ~ 400KPa 1.0 0 ~ 400KPa E5 120.0 ~ 400KPa 1.0 0 ~ 0.6MPa F1 0.2 ~ 0.6MPa 2.0 0 ~ 1.0MPa F2 0.3 ~ 1.0MPa 2.0 0 ~ 1.6MPa F3 0.6 ~ 2.0MPa 4.0 0 ~ 2.0MPa F4 0.6 ~ 2.0MPa 4.0 0 ~ 2.5MPa F5 1.2 ~ 4.0MPa 4.0 0 ~ 4.0MPa F6 1.2 ~ 4.0MPa 6.0 0 ~ 6.0MPa F7 2.0 ~ 6.0MPa 9.0 0 ~ 10MPa H1 3.0 ~ 10MPa 20 0 ~ 30MPa H2 3.0 ~ 30MPa 60 -2 ~ 2KPa C1 2.0 ~ 7.0KPa 0.6 -5 ~ 5KPa C2 5.0 ~ 20KPa 0.6 -10 ~ 10KPa C3 2.0 ~ 20KPa 0.6 -20 ~ 20KPa C4 8.0 ~ 20KPa 0.6 -50 ~ 50KPa C5 10.0 ~ 100KPa 0.6 
Contact Detail
Company Name: Hong Kong Chang Hui Automation Instrumentation Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Western()
Telephone Number: 0371-60397495
Company Address: Zhengzhou City, the Central Plains Road 188, Zhengzhou City, Henan Province, China
Zip/Postal Code: 450005
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450