bios gas flowmeter Defender520L
bios gas flowmeter Defender520L
|
Defender510 / 520/530 gas flow calibrator details Defender 510/520/530 is a new generation of dry gas flow meter, which is a flow meter, and a large number of individual pump recommended by the manufacturer and supporting the use. It can be used for industrial hygiene, environmental protection and various laboratories. It uses the principle of a dry piston movement, one button to generate a plurality of consecutive readings. Compared with the traditional foam-type flow meter, easier to use and fast. 520 models tested simultaneously increasing the temperature and pressure capabilities than 510. Features: a primary standard, NIST traceable unit · displays of: mL, L, cc, cfm · Accuracy: ± 1% · Continuous automatic measurement, can quickly and easily adjust the air flow velocity Automatic calculation of mining multi-point average value, up to 100 data Gan graphite piston design, no soap bubble solution, measuring rapid ? When suspended, automatically shut down within five minutes the power saving function to save battery power · pressurized intake or exhaust all negative Measurable Can be connected to a PC to download the corrected data results * Optional transfer criticize the volume flow rate under standard conditions * With self-test function internal leak Defender510 / 520/530 select different models to meet different customer needs. Model Defender 510 Defender 520 Defender 530 flow range 510L, 5-500ml / min 510M, 50-5000ml / min 510H, 300-30000ml / min 520L, 5-500ml / min 530L, 5-500 ccm 520M, 50-5000ml / min 530M, 50-5000 ccm 520H, 300-30000ml / min 530H, 300-30000ccm flow accuracy of 1% 1% 1% accuracy standard N / AN / A 1.2% selectable units of measure flow mL / min, L / min, cc / min, cf / min mL / min, L / min, cc / min, cf / min mL / min, L / min, cc / min, cf / min standardized N / AN / A smL / min, sL / min scc / min, scf / min Temperature N / A ℃ ℉ ℃ ℉ Pressure N / A mmHg, PSI, kPa mmHg, PSI, kPa temperature and pressure sensors Pressure No Yes Yes N / A 3.5mmHg (typical), 7.0mm (maximum) 3.5mmHg (typical), 7.0mm (maximum) temperature N / A 0.8 ℃ (typical) 1.3 ℃ (maximum) 0.8 ℃ (typical) 1.3 ℃ (maximum) for each reading time from 1 to 15 seconds reading mode (select from 1 to the average of 100 measurements) Single (manual), continuous or burst mode gas No corrosive gas compatibility, non-condensing gases, humidity less than 70% of the flow pattern measuring pressure or suction unit integrated AC AC-DC converter / charger 12V DC,> 250ma, 2.5mm center position Battery System Battery Type 6V rechargeable sealed lead-acid battery, the typical operating time of 6 to 8 hours battery run time (5 times / min) backlight open three hours, the backlight is off 8 hours pressed or the suction hose attachment operating pressure (absolute) 15 PSI graphic LCD display with backlight liquid crystal display data port (using optimization software) RS-232 serial data cable (using optimization software) 1m Defender calibrator to a computer Serial Dimensions (H x W x D) 140x150x75mm Weight 820g
Contact Detail
Company Name: | Shenzhen City Quest Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Shi Health() |
Telephone Number: | 0755-26433515-805 |
Company Address: | Shenzhen, Shenzhen City, Guangdong, China |
Zip/Postal Code: |
Find More Related Products
- Supply of electromagnetic f..
- Supply FR-EDC flowmeter ele..
- The target type flowmeter m..
- Supply of electromagnetic f..
- Flanged flow indicator FR-Z..
- HYDP Balanced meter meter A..
- German direct Brand QA-QAE-..
- 130BAR pressure cleaner HD6..
- The new shaftless screw con..
- DKJ rotary actuators
- DKJ electronic rotary elect..
- HYDP balanced-meter Anji Ho..
- Bernard electric actuator
- Electric Actuator
- Qing silver coins Guangxu i..
- SCHROFF drives
- Dry magnetic separator manu..
- DKZ electronic line straigh..
- Siemens electric control ac..
- CN7505A2001, CN7510A2001, C..