Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

GC 910/310 GC gas chromatography, portable gas chromatograph gasc ..

GC 910/310 GC gas chromatography, portable gas chromatograph gasc ..
GC 910/310 GC gas chromatography, portable gas chromatograph gasc ..
GC 910/310 GC gas chromatography, portable gas chromatograph gasc ..

Larger photo of automa dispenser

Company:Rome Technology (Beijing) Co., Ltd.
Information Name: GC 910/310 GC gas chromatography, portable gas chromatograph gasc ..
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Products: 910/310 GC gas chromatograph Profile 910/310 GC gas chromatograph (GC, chromatograph, chromatography, gas chromatography, portable gas chromatograph) in laboratory applications, 910GC Gas Chromatograph daily industrial analysis and research complex separation well done to generate accurate and reproducible results. Based durable, portable design, compact 310GC gas chromatograph is ideal for field testing gas chromatograph analysis system, in line with the US EPA and ASTM standard method described can be easily done in the field, even in harsh environments under It can be well done. Use 910/310 GC gas chromatograph to obtain reliable high-quality results. With the versatility of 910/310 GC gas chromatograph to meet the different needs of 910/310 GC laboratory gas chromatograph unique internal architecture allows system specific GC detectors and different injection injector with, so each 910 / 310 GC gas chromatography according to user requirements of different laboratories alone configuration. Full size 910GC GC can accommodate a plurality of For injection injector and detector for multi-purpose applications; and a smaller size 310GC GC also has a flexible and portable field analysis capabilities. Automated analysis -910/310 GC gas chromatograph to complete the user can not be qualified to work 910/310 GC gas chromatograph using PS GC software application parameters can be fully controlled, PS GC applications allow unlimited temperature programming, electronics pressure control, carrier gas pressure, throttle position, gas solenoid driven autosampler control, and other optional items. Users only need to enter the application parameters to control the PC, 910/310 GC gas chromatograph to complete the analysis. 910/310 GC gas chromatograph technical features optional double column oven, for a number of chromatographic analysis;?? Furnace temperature from 50oC / min to 300oC and 20oC / min can be programmed from 300oC to 450oC;? PS GC application software adaptation Windons operating system, built-in 4-channel serial data systems;? furnace temperature from 400oC to 50oC rapid cooling, less than 5 minutes to complete, provide a model test analysis of yield;? Built-in valve system with flexible and deal with different accuracy application;? Electronic Pressure Control (EPC) remained stable over the full temperature range limits, and holding time are more stable. ? In demanding laboratory or field conditions, the completion of research-grade mass analysis. ? Up to 12 different detectors optional items to choose from, the best measurement results; 910/310 GC gas chromatography detector supporting a total of nine models to choose from. You can select different categories according to the user's application detector combinations. The gas chromatograph supporting detector comprises: 1) thermal conductivity detector (Thermal Conductivity Detector); 2) a flame ionization detector (Flame Ionization Detector); 3) dry electrolytic conductivity detector Dry Electro-Lytic Conductivity Detector); 4 ) helium ionization detector (Helium Ionization Detector); 5) NPD Nitrogen Phosphorus Detector); 6) electron capture detector (Electron Capture Detector) 7) photo-ionization detector Photo-Ionization Detector) 8) flame photometry detector) Flame Photometric Detector); 9) catalytic combustion detector) Catalytic Combustion Detector); 10) above the detector depending on the application needs, arranged in the following manner: 11) FID-DELCD, TCD-FID, PID-FID- DELCD , NPD-DELCD, FID-FPD 910/310 GC gas chromatograph supporting a variety of micro-syringe, the user can measure the specific application needs, detection limits or management standards for matching. 1) column injection injector (On-Column Injector); 2) heating split / splitless injector (Heated Split / Splitless Injector); 3) 10-port gas sampling valve & oven heating valve (10 Port Gas Sampling Valve & Heated Valve Oven); 4) heating static headspace (Heated Static Headspace Injector); 5) cleaning methods comply with EPA Method 5030/5035 & capture injection injector (EPA Method 5030/5035 Compliant Purge & Trap) ;? 910/310 GC gas chromatograph supporting software main function manually re-integration map;? overlapping chromatograms;? Click and drag the window to retain;? baseline subtraction;? color printing chromatograms;? Multi-level calibration curve;? autosampler and batch queue manual / automatic control external events;?? enlarge a specific area of ??EPC data and HPLC gradient program;?? temperature programming;? dynamic data exchange; 910/310 GC gas chromatograph offers the following optional Item vacuum pump interfaces;??? packed and capillary column methane annex;? Built-in air compressor, a hydrogen generator;? gas pipeline installation kit;? GC mention maintenance kit; 910/310 GC gas chromatograph Technical Specifications Indicator 1) Furnace Size: 19 X 20 X 7.5 CM 2) Temperature: ambient temperature to 450 ℃, accuracy: 0.1 ℃ to 400 ℃; 3) Temperature program: Column oven temperature by PS GC applications software. Without temperature regulator step; 4) temperature / pressure: multifunction LCD display shows a heating zone and the actual temperature, voltage and current probes. Temperature display accuracy to 0.1 ℃, pressure display accuracy to 0.1PSI; 5) carrier gas control: high-precision flow pressure relief valve, with thermostatic flow control; calibrated in PSI unit display provides cylinder gas flow rate adjustment; 6 ) 910/310 GC gas chromatograph Weight: about 30 kg; 7) 910/310 GC gas chromatograph Dimensions: 45.5 x 35.5 x 33 CM 8) 910/310 GC gas chromatograph Power: 220VAC / 50Hz 9) 910/310 GC gas chromatograph power: 700 watts; if you are interested in the gas chromatograph 910/310 GC, please contact us for more detailed information! Rome Technology (Beijing) Co., Ltd. (Materials Science Department) Tel: 010-57130073 13910046648 Fax: 010-58144085 QQ: 70609221 E-mail: sale@tungroma.com Website: www.tungroma.com microblogging: http: // weibo.com/733085677 
Contact Detail
Company Name: Rome Technology (Beijing) Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Han Lei(Sales Manager)
Telephone Number: 010-57130073
Company Address: Block 22 East Third Ring Road, Chaoyang District Hujialou Zijinghaoting B, Chaoyang City, Beijing, China
Zip/Postal Code: 100035
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450