Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Advanced computer simulation of human CPR

Advanced computer simulation of human CPR
Advanced computer simulation of human CPR
Advanced computer simulation of human CPR

Larger photo of automa dispenser

Company:Haibo Friends of Science and Education Equipment Co., L..
Information Name: Advanced computer simulation of human CPR
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
BOU / CPR690 large-screen LCD color display advanced computer simulation of human CPR, first aid mannequins, 2010 Standard Guide, full voice and text prompts to monitor various operations index, assessment, printing and other functions of the product features a comprehensive upgrade, the full LCD display. CPR training operations outstanding auxiliary functions, and you can set the value yourself. More in line with clinical practice and teaching CPR operational requirements. Standard: American Heart Association (AHA) 2010 International cardiopulmonary resuscitation (CPR) & Emergency Cardiovascular Care (ECC) guidance standard Features: ■ 8-inch color display: Analog heart beat display, analog ECG, mega-chart statistics, CPR operating animation, the use of Chinese text. ■ Sims obvious anatomical features, feel real, unified color, shape realistic aesthetic appearance. ■ Simulation of vital signs:? The initial state, Sims mydriasis, carotid no pulse. ? Compressions, Sims passive carotid pulse, pulse frequency consistent with the pressing frequency. ? After successful treatment, Sims pupil returned to normal, the carotid pulse autonomy. ? Pupil Zoom and carotid pulse can be turned on and off by a switch. ■ artificial respiration and heart compressions. Available for standard open airway, airway indicator lights. ■ three operating modes: available for CPR training, examination and practical assessment mode. ? One way: CPR training, can be pressed and blowing training. ? Way: pattern evaluation, within a set period of time, according to the 2010 international standard cardiopulmonary resuscitation, the correct number of pressing and blowing 30: 2 ratio, complete five cycles operation. ? Three ways: the actual assessment, the teacher can set the operating time, operating standards, cycles, frequency, and the ratio of the pressing blowing operation. The controller display features: ■ Electronic monitoring: Electronic Indicator monitor airway open and pressed parts. Correctly count the number of artificial respiration and chest compressions and count the number of errors. ■ Voice prompts: Training and assessment in the whole Chinese voice prompts, you can turn on and turn off voice, adjust the volume. ■ Text Tip: training and assessment in the whole Chinese text prompts. ■ barcode displayed blowing amount: the right amount of blowing 500 ~ 600ml-1000ml:? Blowing amount is too small, the bar code is yellow. ? When the gas flow rate appropriate bar code green. ? When the blowing is too large, the bar code is red. ? Tidal volume blown too fast or oversized, causing gas to enter the stomach indicator lights; digital count display; error language tips; ■ barcode display compression depth, the correct compression depth 5-6cm: compression depth is too small, the bar code is? yellow. ? Compression depth appropriate, the bar code is green. ? Compression depth is too large, the bar code is red. ■ can set their own hours of operation, in seconds. ■ Operating Frequency: 2010 standard of at least 100 beats / min, but also set a value on their own. ■ Power state: with 220V power supply, after the regulator regulated output supply 12V. (Optional lithium battery installed, directly applicable to the case where no external power supply.) The printer features: ■ After operating the printing procedure. ■ transcripts covering operation, judgment awareness, first aid respiration, pulse check, check breathing, remove foreign bodies, operating frequency, pressing and blowing ratio, the number of cycles, the number of pressing and blowing each cycle of operation, press the right / the number of errors, and the number of pressing the wrong reasons, blowing right / wrong reasons and times, blowing the wrong reasons, the set time, and the evaluation of operating time. Material Features: ■ face skin, neck skin, chest skin, hair, imported blend of thermoplastic elastomer material, stainless steel mold, the injection molding machine high temperature injection pressure is made with accurate anatomical landmarks, feel real, unified color, shape vivid, beautiful appearance, durable, decontamination is not deformed, easy disassembly and replacement features, the material reaches the same level abroad. Standard set configurations: ■ Advanced resuscitation mannequin a body; ■ Advanced Display Controller A; ■ luxury hand push me a hard plastic body; ■ a recovery operation pad; ■ a power adapter; ■ data cable root; ■ barrier mask (50 / box) box; ■ four interchangeable lung bladder assembly; ■ can change a dough; ■ thermal paper vols; ■ 2010 international latest Operation Guide CD 1; ■ Aid Manual 1; ■ Owner's Manual a; ■ warranty card, certificate; 
Contact Detail
Company Name: Haibo Friends of Science and Education Equipment Co., L..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Jerry Lamb()
Telephone Number: 021-56658787
Company Address: Songjiang, , Shanghai, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450