Heng Hing factory fire exhaust fan fire exhaust wind chassis air conditioning diagram

Heng Hing factory fire exhaust fan fire exhaust wind chassis air conditioning diagram
Heng Hing factory fire exhaust fan fire exhaust wind chassis air conditioning diagram
Heng Hing factory fire exhaust fan fire exhaust wind chassis air conditioning diagram

Larger photo of automa dispenser

Company:Air Conditioning Co., Ltd. Shandong Heng Hing
Information Name: Heng Hing factory fire exhaust fan fire exhaust wind chassis air conditioning diagram
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Air volume calculation method to select the desired fan according to arrangement of kitchen space and fume hood are as follows: 1, the overall exhaust volume, according to the kitchen space, air changes per hour 40-60 times. Such as kitchen total area of ??160 square meters, a height of 3 meters. We need ventilation to 160X3X60 = 28800m3 / h. 2, local kitchen exhaust hood according to the windward side (minus the perimeter wall of the fume hood length), the wind speed of about 0.5 meters per second. Such as kitchen exhaust hood perimeter of 25 meters, where the wall length of 10 meters. The amount of ventilation required to 3600X (25-10) X0.5 = 27000m3 / h II: Calculation of the required static pressure fan duct according to the situation: 1, based on the amount of wind and wind speed (wind speed 10-15 m / s or so) to determine duct cross-sectional area. Duct aspect ratio should not exceed 2: 1 (to save material and reduce the drag). 2, according to the wind speed, the wind pipe cross-sectional area, elbows, reducers, etc. to calculate the drag (ie the required fan static pressure). Three: calculated based on air flow, static pressure. Select the appropriate fan. When the test at least two persons, one person control power, one observes fan operation, abnormal phenomenon immediately stop inspection; First check the direction of rotation is correct; after the fan begins to run should immediately check the operating current of each phase is balanced, whether the current exceed the rated current; if not normal, should be down to check. After running for five minutes, the fan down to check whether there is abnormal phenomenon, confirmed that no anomalies start running again. When the exhaust fan up to speed, it should measure the input current is normal exhaust fan, exhaust fan operating current can not exceed the rated current. If the operating current exceeds the rated current, should check the supply voltage is normal. 
Contact Detail
Company Name: Air Conditioning Co., Ltd. Shandong Heng Hing
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang Xifeng()
Telephone Number: 0534-5590537
Company Address: Texas, Germany City, Shandong Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450