Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

ABBACS550 drive F04 alarm service

ABBACS550 drive F04 alarm service
ABBACS550 drive F04 alarm service
ABBACS550 drive F04 alarm service

Larger photo of automa dispenser

Company:Guangzhou county controlled automatic control Technolog..
Information Name: ABBACS550 drive F04 alarm service
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
ABB ACS550 drive repair ABBacs550 alarm F04 is ABB high performance vector control inverter, compact design, wide power range. User Manual in small power and high-power: ACS550-01 / U1 User's Manual power range (0.75 ... 160 kW). ACS550-02 / U2 User's Manual power range (200 ... 355 kW). Customer contact a ABBacs550-01-246a (132kw) inverter, normal use before the National Day, the boot fault message F04 discharged after false. F04 This output short circuit failures are generally meant to guide plant electricians disconnect uvw motor output line, no-load start the fault persists, determined drive bad. ACS550 output short circuit integrates a number of detection, the module short circuit, output driver board imbalance, the drive pulse processing board failure, have reported F04. After a detailed inspection, found no problem of power IGBT module, the drive pulse detection, discovery-driven deterioration board a 270 ohm resistor. After the substitution, boot normally, the load test of the indicators correctly, the drive normal repair. Analyze the causes deterioration chip resistors are generally a gradual process, because this equipment has been used, no problem is found, in fact, the fault has been there, but down over time, the drive to cool back to room temperature after the state, the resistance completely degenerate When starting the inverter board to detect the timing uvw alternately turn angle, when a unit can not provide this parameter, the program defaults to output short circuit, start the alarm. ABBACS500 series of major alarm as follows. 1 OVERCURRENT 2 DC OVERVOLT overcurrent DC overvoltage 3 DEV OVERTEMP Overtemperature 4 SHORT CIRC Short circuit 6 DC UNDERVOLT DC undervoltage 7 AI2 LOSS AI2 lost 21 CURR MEAS Current Measurement (internal fault Current measurement range) 22 SUPPLY PHASE power phase ...... more abb series inverter failure alarm invited our website: http: //www.gzjunkong.com Guangzhou county controlled automatic control technology Co., Ltd. focus on the world inverter, DC drives, servo controller, industrial power supply, measurement and control instrumentation repair and maintenance! Any brand, geographical limitation, reasonable fees, customers can request regular tax receipt issued, may send service engineer's visit! Welcome to the Advisory cooperation. Contact 15013099188 Wang. 
Contact Detail
Company Name: Guangzhou county controlled automatic control Technolog..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang(Maintenance Manager)
Telephone Number: 020-22938756
Company Address: Great downtown Long Lin Road Panyu District No. 18 (near the Jiangxi section) Xin'an Business Center 433, , Guangdong, China