Home
Products
Vary the convenience of customers using 30 cubic meters warehouse detection environment
Vary the convenience of customers using 30 cubic meters warehouse detection environment
Vary the convenience of customers using 30 cubic meters warehouse detection environment
TVOC, the Chinese called total volatile organic compounds, smelly, irritating, can cause the level of immune disorders affecting the central nervous system function, dizziness, headache, drowsiness, weakness, chest tightness and other symptoms. The main hazards of formaldehyde on the skin and mucous membrane irritation performance in, can cause redness, itching, throat discomfort or pain, hoarseness, sneezing, chest tightness, wheezing, dermatitis. Under severe circumstances, TVOC and formaldehyde are carcinogenic. 30 m3 test chamber Environmental test chambers test items that are used to detect air purifiers and related domestic air purification devices, test items include: 2.1 air purifier particle removal efficiency; 2.2 air purifier chemical pollutants (formaldehyde, ammonia , benzene, etc.) purification efficiency; 2.3 air purifiers efficiency of micro-organisms (bacteria or specific bacteria naturally); the clean air volume 2.4; 2.5 air purifiers effectiveness; the power consumption of the air purifier 2.6; 2.7 Air Purifier Noise rating. Real-time monitoring, recording cabin temperature, humidity, pressure, displacement rate, and time control parameters. Touch control screen as the personnel to operate the equipment dialogue interface, intuitive and convenient. Configure a dedicated control software, in addition to achieve the touch screen function, but also has a remote control function, system control, program settings, dynamic data display and historical data playback, fault recording, alarm settings. Applicable standards of this device: ● GB 21551.3-2010 "Household and similar electrical appliances antibacterial, sterilization function air purifier special request" ● GB 21551.6-2010 "Household and similar electrical appliances antibacterial, sterilization functional air conditioner special requirements" ● JG / T 294-2010 "air purifier pollutant removal performance measurement" ● GB / T 18801-2008 "air purifier" ● ANSI / AHAM AC-1 2006 "Method for measuring performance of portable household electric room air cleaners" technology and performance indicators 1, temperature: adjustment range: (10 ~ 40) ℃ regulation accuracy: ± 0.5 ℃ 2, relative humidity: adjustment range: (40 ~ 70)% RH regulation accuracy:. ± 3% RH 3. Flow Rate: 200-2000 cubic meters per hour (adjustable); 4. Surface Winds: horizontal, whole section of the air circulation, the air is maintained at the level of the rate (0.1 ~ 0.3) m / s, accuracy ≤0.05m / s 5. Test chamber size (interior): 30m3 (exterior structure according to the actual site settings); 6. Test pressure relative to the outside cabin: 10 ± 5Pa Manufacturer: Jinan Hai Nate Technology Co., Ltd. Contact: Mr. Wang Tel: 0531-85993641,85993642,13064084331 QQ: 507549985 public micro-channel number: JINAN-HAINATE Email: jnhnt @ 163.com Website: http: //www.jnhnt.com
Contact Detail
Company Name: | Jinan Hai Nate Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Wang Rumeng(Marketing Manager) |
Telephone Number: | 0531-85993641 |
Company Address: | Sinsa Huaiyin District of Jinan City Road on the 24th, Jinan City, Shandong Province, China |
Zip/Postal Code: | 250000 |
Find More Related Products
- Supply the Japanese origina..
- ToxiRAEII personal single t..
- Qiu Cixuan broker 186205552..
- PGM-11XX
- BW Quad gas detector
- Gas inspection instrument s..
- Jiande plastic runway whole..
- How wrong version coins Chr..
- CAS100 atmospheric carbon-1..
- MRG10 pavement floor radiat..
- TAM-K-type wide-range air t..
- PGM-2400
- Huarui fast detector PRM-30..
- Wide range of rapid detecti..
- Air Purifier YM-A168-10 ran..
- SPD100 Individual Dose Mana..
- 900+ multifunction digital ..
- 3085-type personal dosimeter
- BS2010 type direct-reading ..
- BS9511Xγ radiation dose de..
- PAA01 type of protective le..