Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Germany and Germany plans testo320 efficient gas analyzer

Germany and Germany plans testo320 efficient gas analyzer
Germany and Germany plans testo320 efficient gas analyzer
Germany and Germany plans testo320 efficient gas analyzer

Larger photo of automa dispenser

Company:Bo Albert Road, Qingdao Environmental Protection Techno..
Information Name: Germany and Germany plans testo320 efficient gas analyzer
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
The new testo 320 is a multifunctional measuring instrument, flue gas analysis can be carried out efficiently. All measurement tasks can easily complete heating system. Numerous measurement menu structure is clear. testo 320 with a high-resolution color display, graphical display measurement results. 500 measurements can be stored within the instrument. Meanwhile testo 320 also has extensive probe group, users do not need to purchase additional individual measuring instrument. High-resolution graphic display shows the measured menus and detailed measurement values, very easy to read. Sensor diagnostic instrument with integrated indicator lights, continuous monitoring equipment sensors. Certification labels flue gas analyzer testo 320 has passed TüV certification (according to EN 50379, Parts 1-3) sensor auto-zero sensor zero just 30 seconds lithium-ion rechargeable battery lithium-ion rechargeable battery (1500 mAh), can Use up to 8 hours. Magnetic back of the instrument with a magnet can be easily mounted on the burner / boiler. Probe probe filter element filter element can be easily replaced testo 320 flue gas measurement direct measurement of CO and O2, as well as ambient temperature and flue gas temperature. Draft measurement can quickly determine the negative pressure within the heating system. Differential pressure measurement using differential pressure measurement menu, the user can monitor the air supply to the boiler. Gas leak / gas pipeline testing using the accessory, users need to purchase additional measuring instruments of. Environmental CO measuring ambient CO probe, while in the flue gas measurement CO measurement environment. Differential temperature measurement using the temperature difference between the measuring menu, the user can quickly and easily measure the difference between the heating system and return water temperature. Technical parameters: Range Accuracy ± 1 digit Resolution Response time t90 temperature -40 to +1200 ° C Accuracy: ± 0,5 ° C (0 to 100 ° C) Accuracy: ± 0.5% measured value (remaining range) 0.1 ° C -40 to + 999,9 ° C 1 ° C (> + 1000 ° C) pumping force measurement -9.99 hPa to +40.00 hPa ± 0.02 hPa or ± 5% measured value (-0,50 to +0,60 hPa) ± 0.03 hPa (0.61 to 3.00 hPa) ± 1.5% measured value (3.01 to 40.00 hPa)) 0.01 hPa using precise pumping power options 0.001 hPa Pressure measurement 0 to +300 hPa ± 0.5 hPa (0.0 to +500 hPa) ± 1% measured values ??(at 50.1 to 100.0 hPa) ± 1,5% measured value (at 100,1 to 300,0 hPa) 0.1 hPa pressure using precision measuring options 0.01 O2 0 to 21 vol.% ± 0.2 vol.% 0.1 vol. % <20 sec CO measurement (without H2 compensation) 0 to 4000 ppm ± 20 ppm (0 to 400 ppm) ± 5% measurement (401 to 2000 ppm) ± 10% measured (2001 to 4000 ppm) 1 ppm <60 sec CO measurement (H 2 compensated) 0 to 8000 ppm ± 10 ppm or +/- 10% of measured value (0 to 200 ppm) ± 20 ppm or +/- 5% of the measured values ??(201 to 2000 ppm) ± 10% measured value ( 2001 to 8000 ppm) 1 ppm <40 sec combustion efficiency (Eta) 0 to 120% 0.1% Flue gas loss 0 to 99.9% 0.1% CO 2 from the O2 calculated from 0 to CO 2 max ± 0.2 vol.% 0.1% selected with CO low - measuring - (H2-compensated) Compensation 0 to 500 ppm ± 2 ppm (0 to 39 ppm) ± 5% measured value (40 to 500 ppm) 0.1 ppm <40 sec environment CO measurement (with CO probe) 0 to 500 ppm ± 5 ppm (0 to 100 ppm) ± 5% measured value (> 100 ppm) 1 ppm combustible gas leak detection (using gas leak detection probe) 0 to 10.000 ppm CH 4 / C 3 H 8 optical alarm display (LED) Buzzer sounds alarm <2 sec ambient CO2 measurement (with ambient CO2 probe) 0 to 1 vol.% 0 to 10,000 ppm ± 50 ppm or ± 2% measured value (0 to 5000 ppm) ± 100 ppm or ± 3% measured value (5001 to 100000 ppm) General Technical Data Storage temperature -20 - +50 ° C operating temperature -5 - +45 ° C Power rechargeable battery:. 3.7 V / 2400 mAh; Power: 6 V / 1.2 A memory 500 readings screen display color graphics display, 240 x 320 pixels Weight 573 g Dimensions length 240 x width 85 x height 65 mm Warranty Instrument / probe / gas sensors: two months Rechargeable battery: 12 months 
Contact Detail
Company Name: Bo Albert Road, Qingdao Environmental Protection Techno..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Sun Xiaomei(Instruments Business Manager)
Telephone Number: 0532-80686760 0532-806867087
Company Address: Qingdao City, Lee Chang Hechuan Road on the 19th, Qingdao City, Shandong Province, China
Zip/Postal Code: 266012
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450