Direct-reading spectrometer PDA-8000
Direct-reading spectrometer PDA-8000
|
Direct-reading spectrometer PDA-8000 Elemental analysis -PDA-8000 high-resolution stable splitter splitter high stability, performance excellence. Its condenser system with an advanced optical design, implementation, measurement of high sensitivity, high stability. Inhibit phosphorus (P), sulfur (S), the interference impact, thereby performing correct analysis. The new excitation power having excitation between the electrodes and the sample can be generated in real-time monitoring. Instant judgment bad discharge defects caused by the surface of the sample removed from the measured data, thereby improving accuracy. Substantial energy saving. User-friendly operating software user-friendly interface, real-time monitoring and control details splitter vacuum and light source device, easy maintenance tips when maintenance management step, from the control, management is determined to sit back and relax. grayicon.gif list of elements can be determined to match various analytical objects can set the optimum discharge conditions. Using high-resolution optical splitter to achieve a more accurate analysis of steel and non-ferrous metals were used to match the wavelength range of the focal length of 1000mm grating. Wavelength range is wide, high-resolution metering, interference suppression, thereby enabling accurate analysis. High stability, excellent performance vacuum splitter material analysis of phosphorus and sulfur is an important element. Phosphorus and sulfur 190nm or less in wavelength, the wavelength range of the spectral line of vacuum ultraviolet region. Because oxygen in the air can absorb light in this wavelength range, it is necessary to vacuum. PDA-8000 uses superior performance vacuum splitter to ensure the stability of spectral analysis. Condenser system through the exit slit of light through the curved mirrors focus, exposure to the light receiving surface of the photomultiplier tube. Such optical design, can be stable photometry. Tackling climate change strategies splitter using a small temperature change material, thermal insulation installed in strengthening the function of thermostatic chamber, room temperature changes affected the formation of a structure, to provide a stable analysis. (Room temperature 10-30 ℃ ± 5 ℃ / less than h) real-time monitoring of the status of an excitation discharge between the electrodes and the sample can be generated in real-time monitoring function ※ (Realtime Energy Monitoring), this function can be set correctly control the excitation energy, the moment Analyzing the sample surface bad discharge, removed from the data processing, thereby improving the accuracy. Comprehensive response to all the newly developed metal material excitation light source stability, high melting point metal and steel high energy discharge, low melting point metals zinc, lead alloys and other low energy discharge, high-power excitation light source to choose the most suitable of various metals Discharge conditions were analyzed. Very small amount of high-purity materials analysis constant current discharge ※ (CRS-Current Regulative Spark) can release a stable discharge current from each pulse, in order to achieve high sensitivity in a very small amount in the field. Energy-saving design power (reduction compared to 43% ※ 1 and the Company's conventional models) energy-saving device is 510W. (The company's traditional model and reduce argon consumption compared to 45% ※ 2) (※ 1 to 1 hour 15 samples were analyzed to calculate ※ 2 8 hours a day standards, 150 samples were analyzed for the standard calculation) Operating Meet simple, to provide comprehensive management of hardware and software control · Analysis of the blend from the control unit determines the maintenance, easy to get. The integration of software and hardware device management peace of mind. Reliable, easy to operate in pursuit of a more photoemission spectra of the development on the road to profound knowledge to realize the operator's considerate and concise elegant design combined. Different sample analysis programs are also different, more clear and intuitive operation.
Contact Detail
Company Name: | Guangzhou Yihua new electronic devices Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Yihua new() |
Telephone Number: | 020-36453501 |
Company Address: | Yellow edge Road 122, Baiyun District, Guangzhou Jiahe Industrial Park, Guangzhou, Guangdong, China |
Zip/Postal Code: | 510000 |
Find More Related Products
- Surgical lights surgical li..
- Spectroscope wkX-10
- Spectroscope portable wkx-1..
- Spectroscope wkt-6
- Spectroscope portable WX-5
- CE, RoHS, FCC, CCC, UL, CB,..
- Supply Steel Institute ng d..
- The full spectrum of direct..
- Spectrometer Standard, meta..
- XMET7500 ray portable spect..
- X-ray fluorescence spectrom..
- XMET7000 ray Handheld Spect..
- Steel Institute ng spark di..
- Infrared spectrophotometer ..
- Italian Woqi portable measu..
- Automotive brake oil moistu..
- Automotive brake fluid mois..
- Beijing ng food heavy metal..
- Full metal samples elementa..
- Ng metallurgy spark direct ..
- Sunsilk soap Agents Wholesa..