Hydrogen leak alarm RBK-6000-6 Type
Hydrogen leak alarm RBK-6000-6 Type
|
RBK-6000-6 type hydrogen hydrogen gas alarm controller to the digital signal generated by the detector is sampled by the internal single-chip data processing, real-time display of concentration detector, status (audible alarm), physical address and other information, and output control signal. Fully fault self-test function, fault location and type of real-time display system and the sub-address (audible alarm). This product is designed to follow the national standards for GB16808-2008, compared with traditional products, with a clock display, alarm time access, independent set, zero drift homing and other new features, and the system looks, intuitive display, clarity high, each functional operation has a corresponding icon mate, the operation is very simple, centralized control of the entire product design, easy to query and maintenance. Product Certifications: ISO9001: 2000 quality management system standards, fire product type approval certificate, inspection reports, measurement equipment manufacturing license, explosion-proof certification. RBK-6000-6 type hydrogen alarm controller Features: ◆ high accuracy control of high-speed high-grade single-chip CPU, computing speed, high precision and reliability, can handle the task quickly and accurately, to ensure system reliability. ◆ system design system is modular in design, easy to maintain processing system. ◆ hybrid configuration to achieve combustible and toxic gas detectors mixed on the same system configuration. ◆ Installation is extremely simple and easy to install, easy to operate. ◆ variety of signal output 4-20mA standard current signal output, 485 serial communication interface, two sets of passive alarm relay contact output. ◆ easy maintenance of the product design is modular design for easy system combination and maintenance. RBK-6000-6 type hydrogen alarm controller technical parameters Certification ◆ Ministry of Public Security Fire Electronic Product conformity assessment center ◆ Application Standard: GB16808-2008 electrical ◆ Power supply: 195 ~ 235VAC / 50 ~ 60Hz ◆ Control output: Relay AC220V / 5A ( 2 passive normally open normally closed) ◆ Terminals: for wire cross-sectional area 0.5-2.5mm2 ◆ Connection: Three-wire structure ◆ 3 * 1.0mm2 Installation: Wall, panel mounted or rackmount ◆ Weight: ≤3.5 kg ◆ Dimensions: 340mm (L) × 240mm (W) × 80mm (H) Environment ◆ Operating temperature: -20 ℃ ~ 60 ℃ ◆ Operating Humidity: ≤95% RH (non-condensing) ◆ pressure range: 86 ~ 106kPa ◆ Transmission distance: ≤1200m display ◆ alarm display unit:% LEL ◆ Alarm: sound and light alarm ◆ Alarm volume: ≥75dB product installation detector supporting the use of: RBT-6000-F, RBT-6000-FX type hydrogen detector ; the number of connected detectors ◆: 3 to 6 can be connected to gas detectors; ◆ with gas detectors wiring: Three-wire 3 * 1.0mm2; ◆ gas alarm controller not explosion-proof products should be installed in the control room or indoor security zone or explosive gas environment, the use of wall-mounted; ◆ install a reasonable choice of mounting height, easy operation can not be too low, to avoid accidental injury to persons requiring walls to firm and smooth. http://www.abc1718.cn/anqijianceyi/ RBT-6000-F hydrogen detector RBT-6000-F is a no show, the digital signal output of explosion-proof hydrogen detectors, each detector, only against one gas detection. RBT-6000-F-type hydrogen detector in the industrial gas leak detection alarm device, is industrial combustible gases and toxic gas safety testing equipment. It can be installed in a hydrogen leak is fixed indoor and outdoor hazardous locations. Play the role of site monitoring, if monitoring Location hydrogen leak, the probe will be the first time, the hydrogen concentration data to spot leaks, transmitted to the gas alarm controller by gas alarm controller for data processing. This product is designed to follow the national standards GB15322.1-2003. Product Certifications: ISO9001: 2000 quality management system standards, fire product type approval certificate, inspection reports, measurement equipment manufacturing license, explosion-proof certification. RBT-6000-F Hydrogen Detector Features ◆ measurement accuracy imported sensor sensitive components, with high accuracy, interchangeability, high reliability. ◆ digital compared to analog signal 4-20mA standard current signal, without first for commissioning before the exchange may at any time freely exchange gas detector position, easier to maintain. Advantages of high accuracy, transmission distance, interference well. ◆ industrialized docking system may need to be adjusted user signal output according to the connection with the DCS, PLC and other industrial automation systems engineering. ◆ Explosion-proof can be used in factory conditions 1, 2 dangerous places. ◆ internal movement with easy maintenance kit form, field maintenance, replacement components to complete. ◆ structure of the gas detector detector housing die-cast aluminum material, dual-chamber structure designed to avoid accidental water, nearly dust, corrosion, and failure phenomenon, small size, easy installation. ◆ sensors Protective sensors detect a head portion made of stainless steel, effectively it plays the role of anti-corrosion; too sensor mesh stainless steel particles, good air permeability. RBT-6000-F hydrogen detector technology parameters Certification ◆ Explosion-proof: Exd II CT6 ◆ Type approval: Fire Electronic Product conformity assessment center ◆ Application Standard: GB15322.1-2003 electrical ◆ Power supply: DC12V-30V ◆ Signal: digital signal ◆ Terminals: for wire cross-section 0.5 ~ 2.5mm2 ◆ connection cable: 3 × 1.0mm2 ◆ Connection: Three-wire ◆ Accuracy: ± 5% FS ◆ Response time: less than 30s environment ◆ IP rating: IP65 ◆ Temperature range: - 40 ℃ ~ 65 ℃ (catalytic combustion) | -40 ℃ ~ 65 ℃ (electrochemical, non-permanent) ◆ Humidity: 10 ~ 95% RH (non-condensing) ◆ pressure range: 86 ~ 106KPa ◆ Storage temperature: - 40 ℃ ~ + 65 ℃ ◆ Transmission distance: ≤1200m detection ◆ Detection of gas: hydrogen ◆ Detection method: natural diffused ◆ Detection range: 12-15m2 product installation ◆ Body Material: Aluminum Material ◆ Dust material: stainless steel dust Net ◆ Explosion-proof connecting thread: G1 / 2 "◆ Weight: 1.5kg ◆ Installation: mounting bracket, tube, wall mounted ◆ Dimension: 126mm Control (L) × 93mm (W) × 62mm (H) ◆ supporting the use of is: RBK-6000-2, RBK-6000-6 type gas alarm controller ◆ gas detectors should be installed in a gas leak prone areas and the specific location should be detected according to the proportion of gas relative to the air decides 1, when the gas to be detected. When the proportion of heavier than air, gas detectors should be installed from the ground (30 ~ 60) cm at the sensor site and down. 2, when the proportion of gas to be detected is less than the proportion of air, gas detectors should be installed at a distance ceiling (30 ~ 60) cm at the sensor site and down ◆ fixed gas detector for gas detection ◆ one detection range: 12-15 square combustible gas catalytic combustion sensor (% LEL), toxic gas using electricity Chemical sensor (ppm, 10ppm) ◆ In order to use gas detectors and gas detectors to prevent faults, do not install in the following locations: Local 1, directly affected by the steam, smoke effects; 2, to the air intake, fan, house air volume flow doors big place; 3, water vapor, water droplets in many places (relative humidity ≥95% RH); 4, the temperature below -40 ℃ or above 65 ℃ place; 5, Jinan-strong electromagnetic fields. Xin Security Equipment Co., Ltd. specializing in the production and sale of gas detectors, gas alarm; at the same time agents of various imported brands, one-stop products and services to meet the various needs of customers please call: 0531-88033177 Mobile: 15063353566 High-manager or enter the site. : http: //www.abc1718.cn more information; online QQ: 857061602
Contact Detail
Company Name: | Jinan Juxin Security Equipment Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. High-manager(Manager) |
Telephone Number: | 0531-88033177 |
Company Address: | Licheng District Hualong Road, , Shandong Province, China |
Zip/Postal Code: | 250000 |
Find More Related Products
- HQKZ-200 hydrogen chloride ..
- Manufacturers supply GC210-..
- Shandong factory direct sup..
- Grape seed oil automatic fi..
- Hydrogen chloride alarm, ch..
- AEC2232a type hydrogen chlo..
- Hulunbeier logistics compan..
- Black steel ginning net pri..
- Black steel ginning net, bl..
- Alcohol Tester / Portable B..
- Three button operation hydr..
- Jinan Han of fixed probe si..
- Hydrogen chloride gas detec..
- Pump-priming hydrogen chlor..
- TESA double-sided adhesive ..
- Hefei official Mitsubishi E..
- Alcohol Tester price amount..
- Trace moisture analyzer Ext..
- AT8000 Alcohol Tester
- Supply YJ0118-3 mine explos..
- Freon leak detector - Freon..