Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

NO alarm, nitric oxide gas alarm, nitric oxide gas concentration reported ..

NO alarm, nitric oxide gas alarm, nitric oxide gas concentration reported ..
NO alarm, nitric oxide gas alarm, nitric oxide gas concentration reported ..
NO alarm, nitric oxide gas alarm, nitric oxide gas concentration reported ..

Larger photo of automa dispenser

Company:Jinan Long Electronics Co., Ltd.
Information Name: NO alarm, nitric oxide gas alarm, nitric oxide gas concentration reported ..
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Industrial fixed gas nitric oxide nitric oxide gas alarm from the alarm control panel and nitric oxide gas detectors, gas alarm control panel can be placed in the duty room, main control for each monitoring point, nitric oxide detector Nitric oxide gas is installed in the place most likely to leak, the core component is a built-in nitric oxide gas sensors, sensors detect airborne concentration of nitric oxide gas. Detector converts the gas concentration detected by the sensor into an electrical signal, transmitted by cable to the control panel, the higher the gas nitric oxide concentration, the electrical signal is stronger, when xylene gas concentration reaches or exceeds the alarm set point alarm controller When the gas alarm control panel alarm signal, and start the solenoid valve, exhaust fan endures associated equipment, automatically excluded risks. Fixed nitric oxide gas alarm using imported catalytic combustion sensor, catalytic combustion principle is to use a refractory metal platinum wire heating the change in resistance is measured concentrations of nitric oxide gas. When nitric oxide gas into the detector, the surface of the platinum wire caused by oxidation (flameless combustion), heat generated increases the temperature of a platinum wire, and a platinum wire resistivity will change. Catalytic combustion sensor for a wide variety of combustible gases have a keen response. This technique has general applicability for combustible gas. Sensors specially designed anti-poisoning function reliably in most industrial environments work five to ten years. Nitric oxide leakage alarm 24-hour service hotline: 15668389633 Wang Peng, at any time waiting for your call. First, the characteristics of nitric oxide gas alarm control host: gas controller for gas detectors produce a digital signal is sampled by the internal single-chip data processing, real-time display of concentration detector, status (audible alarm), physical address and other information, and outputs a control signal. Fully fault self-test function, fault location and type of real-time display system and the sub-address (audible alarm). This product is designed to follow the national standards GB16808-2008, qualifications have ISO9001: 2008 quality management system standards, fire product type approval certificate, inspection reports, measurement equipment manufacturing license, explosion-proof certification. Compared with traditional products, with a clock display, alarm time access, independent set, zero drift homing and other new features, and the system looks, intuitive display, high definition, operate each function has a corresponding icon mate operation is very simple, centralized control of the entire product design, ease of inquiries and maintenance. Gas alarm controller supporting the use of gas detectors should be. Second, the nitric oxide gas alarm control panel model: RBK-6000, RBK-6000-2, RBK-6000-6, RBK-6000-Z, RBK-1080 a total of five models. Third, the nitric oxide gas alarm control panel Features: ◆ high accuracy: CPU controller with high-speed high-end microcontroller, computing speed, high precision and reliability, can handle the task quickly and accurately, to ensure system reliability . ◆ System: The system uses a modular design for easy maintenance processing systems. ◆ hybrid configuration: to achieve combustible and toxic gas detectors mixed on the same system configuration. ◆ Installation is simple: the controller and detector installation requires only a shielded cable can, installation is very simple to operate, there is no positive and negative requirements, core free to connect, installation material costs by four percent ten or more. ◆ variety of signal outputs: 4-20mA standard current signal output, 485 serial communication interface, two sets of passive alarm relay contact output. ◆ Easy maintenance: the entire product design is modular design for easy system combination and maintenance. Fourth, the nitric oxide gas alarm control host technical parameters: Authentication ◆ Ministry of Public Security Fire Electronic Product conformity assessment center ◆ Application Standard: GB16808-2008 electrical ◆ Power supply: 195 ~ 235VAC / 50 ~ 60Hz ◆ Control output: Relay AC220V / 5A (2 passive normally open normally closed) ◆ Terminals: for wire cross-sectional area 0.5-2.5mm2 ◆ Connection: two-wire, three-wire, four-bus system architecture ◆ Installation: Wall, panel mounted or rackmount ◆ Weight: ≤3.5kg ◆ Dimensions: 302mm (L) × 240mm (W) × 82mm (H) Environment ◆ Operating temperature: -20 ℃ ~ 60 ℃ ◆ Operating Humidity: ≤95% RH (non-condensing) ◆ pressure range: 86 ~ 106kPa ◆ Transmission distance: ≤800m display ◆ alarm display unit :( flammable gas) is% LEL (poisonous gas) is ppm ◆ Alarm: sound and light alarm ◆ Alarm volume: ≥75dB five, a nitric oxide gas alarm control host installation: ◆ detector supporting the use of: RBT-6000 type gas detectors; ◆ the number of connected detectors: In accordance with the requirements of the number of connections suitable gas detectors and gas detectors ◆ Connection: Two-wire wire, three-wire, four-bus system gas alarm controller ◆ not explosion-proof products should be installed in the control room or indoor safe area non-explosive gas environment or using wall mount; ◆ install a reasonable choice of mounting height, easy to operate It can not be too low, to avoid accidental injury to persons requiring walls to firm and smooth. Sixth, an overview of nitric oxide gas detectors: gas detector is a digital signal output of flammable, toxic gas explosion-proof detectors, gas detectors each, only for a gas detection. Its models are as follows: RBT-6000, RBT-6000-ZX, RBT-6000-Z, RBT-6000-FX, RBT-6000-F, RBT-1060, RBT-1060 / C. This product is designed to follow the national standards GB15322.1-2003, qualifications have ISO9001: 2008 quality management system standards, fire product type approval certificate, inspection reports, measurement equipment manufacturing license, explosion-proof certification. Gas detectors in the industrial gas leak detection alarm device, is industrial combustible gases and toxic gas safety testing equipment. It can be mounted in a gas leak has tested indoor and outdoor hazardous locations. Site monitoring role to play, if combustible gas monitoring location or toxic gas leak, the gas detector will be the first time, the site leaked flammable, explosive gas or toxic gas concentration data, transmitted to the gas alarm controller by gas alarm controller for data processing. Gas alarm controller supporting the use of gas detectors should be. Seven, nitric oxide gas detectors Features: ◆ measurement accuracy: the use of imported sensitive sensor element with high accuracy, interchangeability, high reliability. ◆ Digital signal: Compared with standard analog 4-20mA current signal, before exchange without first commissioning, you can always freely exchange gas detector position, easier to maintain. Advantages of high accuracy, transmission distance, interference well. ◆ industrialized docking system: Users can adjust the signal output according to need in order to connect with DCS, PLC and other industrial automation systems engineering. ◆ Explosion-proof: it can be used to factory conditions 1, 2 dangerous places. ◆ easy maintenance: the use of components in the form of internal movement, field maintenance, replacement components to complete. ◆ detector structure: gas detector shell is made of die-cast aluminum material, dual-chamber structure designed to avoid accidental water, nearly dust, corrosion, and failure phenomenon, small size, easy installation. ◆ Sensor protection: sensor probe section made of stainless steel, effectively play the role of anti-corrosion; filter sensor's stainless steel particles, good air permeability. 8, technical parameters of nitric oxide gas detectors: Certified ◆ Explosion-proof: Exd II CT6 ◆ Type approval: Fire Electronic Product conformity assessment center ◆ Application Standard: GB15322.1-2003 electrical ◆ Power supply: DC12V-30V ◆ Signal: digital signal ◆ Terminals: for wire cross-section 0.5 ~ 2.5mm2 ◆ connection cable: ≥2 × 2.5mm2 (twisted pair) ◆ Connection: two-wire ◆ Accuracy: ± 5% FS ◆ Response time: less than 30s ◆ Environment IP rating: IP65 ◆ Temperature range: -40 ℃ ~ 55 ℃ (catalytic combustion) | -40 ℃ ~ 55 ℃ (electrochemical, non-permanent) ◆ Humidity: 10 ~ 95% RH (non-condensing) ◆ pressure range : 86 ~ 106KPa ◆ Storage temperature: -20 ℃ ~ + 55 ℃ ◆ Transmission distance: ≤800m detection ◆ Detection of gas: flammable% LEL | hazardous ppm ◆ detection method: natural diffused ◆ Detection range: 12-15m2 Nine, nitric oxide gas sensor installation: ◆ Body Material: Aluminum Material ◆ Dust material: stainless steel air filter ◆ Explosion-proof connecting thread: G1 / 2 "◆ Weight: 1.5kg ◆ Installation: mounting bracket, tube , wall mounted ◆ Dimension: 126mm Controller (L) × 93mm (W) × 62mm (H) ◆ supporting the use of: RBK-6000 type gas alarm controller ◆ gas detectors should be installed in a gas leak prone areas and specific position should be based on the proportion of gas to be detected with respect to the decision of the air. 1, when the detected gas is heavier than air proportion of gas detectors should be installed from the ground (30 ~ 60) cm at the sensor site and down. 2, when when gas is detected specific gravity less than the specific gravity of air, gas detectors should be installed at a distance ceiling (30 ~ 60) cm at the sensor site and down one ◆ fixed gas detector for detecting gas ◆ Detection range: 12- 15 square feet, the combustible gas catalytic combustion sensor (% LEL), toxic gas electrochemical sensors (ppm, 10ppm) ◆ In order to use gas detectors and gas detectors to prevent faults, do not install in the following locations: 1, directly affected by the steam, fumes place; 2, to the air intake, fan, doors and other places large amount of wind flow; 3, water vapor, water droplets in many places (relative humidity ≥95% RH); 4, the temperature at -40 below or above 55 ℃ place ℃; 5, there are strong electromagnetic fields, also known as nitric oxide alarm nitric oxide gas alarm, but also has the following address: Nitric oxide leakage alarm, nitric oxide gas leak alarm , nitric oxide detector, nitric oxide gas detector, nitric oxide gas leak detector, nitric oxide gas leak alarm detector such names. Fixed nitric oxide gas alarm has nitric oxide gas alarm controller and nitric oxide gas detectors, according to the needs of customers ordered the bus system and sub-limit of two modes, different modes with different control panels and detectors, make the selection more flexible. RBK series controller and RBT series detectors is the company based on market needs new and improved product, improved performance after more perfect in all aspects of safety performance also improved. 
Contact Detail
Company Name: Jinan Long Electronics Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Peng()
Telephone Number: 0531-68808013
Company Address: Jinan, Jinan City, Shandong Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450