Fixed Gas Detectors
Fixed Gas Detectors
|
Supply Honeywell / Honeywell Sensepoint XCD fixed gas detectors use catalytic combustion, electrochemical and infrared technology principle, reliable detection of combustible gases in potentially hazardous environments, toxic and oxygen gas detectors common. SensepointXCD gas detector is a fixed installation in the presence of flammable, explosive or toxic gas sites, equipment used to detect flammable gas in air, gas and oxygen concentration. XCD (meaning E xceed beyond) gas detectors gas detection technology to all the benefits rolled into one, is already widely used fixed gas detector replacement products, which cost far more than any similar existing products. SensepointXCD sensors and other core components using patented technology and non-dispersive infrared (NDIR) use of technology to make detection more precise, better long-term stability. XCD same case for catalytic combustion, electrochemical and ND IR variety of sensors, so that the type of gas can be measured more and wider. XCD therefore widely used in general industrial petroleum, chemical, metallurgy, manufacturing, and in some hostile environments environment equally outstanding performance. Universal transmitter platform? Same transmitter for newly developed and existing sensors? Local or remote sensor connections? Application catalytic combustion, electrochemical and infrared technology? Smart Sensor is used to identify the type of gas ranges and other display clear and intuitive? tri-color backlit LCD? distance instantly clear status indication? In poor working conditions environment can clearly identify a variety of signal output? 4 ~ 20m A industry standard current signal? Sensepoint XCD state with automatic alerts, particularly tricolor backlighting use, long range clearly show its working state: When there is no alarm and working, the backlight is green when there is a fault occurs, the backlight is yellow when an alarm occurs, the backlight is red three programmable relay Modbus digital? ? signal SurecellTM and ReflexTM patented high performance sensing technology to measure accurate and reliable measurement of oxygen and the working conditions of the gas sensing element infrared sensor technology to ensure the long-running application areas:????? petrochemical oil refining chemical fertilizer plant Water treatment plant chemical storage car factory plant steel plant laboratory offshore oil and gas exploration and production and distribution of oil and gas storage and transportation refrigeration food / beverage cost-IR solution? long lifetime? anti-poisoning? without oxygen participation of non-intrusive operation? maintenance processes Simple? without opening the transmitter? speed up maintenance plan? strengthen the operator's confidence in shell material? Aluminum? Sensepoint XCD detectors for use in potentially explosive environments, and therefore detectors should be installed in compliance with the relevant standards with a matching mechanical enclosure protection Cables and connectors (M20 or 3/4 "NPT) or conduit length of cable installation needed to use a cross-section of 0.5mm2 to 2.5mm2 cable. Available accessories for different applications to choose from 316 stainless steel is easy to install? Simple plug-in sensors? integrated wall mounting? independent vertical or horizontal pipe mounting kit? 3-wire source or Sinking industry standard signals certification? China GB Ex d IIC T4 GB3836.1 & 2 -2000, PA, CCCF? Korea KTL Ex d II CT6 (-40oC ~ + 65oC)? North America UL? Canadian cUL / CSA? Europe ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC ~ + 65oC) Ex tb IIIC T850C Db IP66? international IEC Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC ~ + 65oC) Ex tb IIIC T850C Db IP66? EMC EN 50270 environment? Protection class IP66? Operating Temperature -40oC ~ + 65oC / -40oF ~ 149oF.? humidity for 20 ~ 90% RH (non-condensing), intermittent 10 ~ 99% RH (non-condensing)? Working pressure 90-110kPa? Storage environment -25oC ~ + 65oC (-13oF ~ + 149oF)
Contact Detail
Company Name: | On the Highland Code Security Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Sales() |
Telephone Number: | 021-60935829-30 021-60935829 |
Company Address: | Shanghai Pudong New Area, Shanghai, Shanghai, China |
Zip/Postal Code: |
Find More Related Products
- Honeywell GAXT-H
- GAXT-H
- GAXT-H-type hydrogen sulfid..
- Handheld sperianH2S spot ga..
- Honeywell H2S gas analyzer
- Fixed (with display) VOC be..
- Anhui - Anqing septic tank ..
- Play Golden Baoson what pro..
- ToxiproH2S single gas conce..
- Honeywell single hydrogen s..
- GAXT-H-DLBW hydrogen sulfid..
- Waterproof handheld hydroge..
- Canada BW hydrogen sulfide ..
- H2S gas leak alarms BW Cana..
- Transfer with a car company..
- Stationary hydrogen sulfide..
- Line hydrogen sulfide detec..
- Handheld hydrogen sulfide d..
- Line dioxide detector BGD-S..
- Carbon Dioxide Analyzer
- US NYAD oxygen carbon dioxi..