Hach 1720E Low Range Turbidimeter with Controller SC200 package online sales
Hach 1720E Low Range Turbidimeter with Controller SC200 package online sales
Hach 1720E Low Range Turbidimeter ★ Online sales package with Controller SC200 1720E supply hash turbidity, agents online turbidimeter Hach HACH turbidimeter sales, industrial turbidity, water turbidity, water turbidity, online water quality instrumentation, heavy metal analysis equipment Typical applications: online turbidity meter can be used on different parts of the filter means for measuring the raw water or purified water turbidity. Hach 1720E Low Range Turbidimeter can be applied in front-line water filtration plant, after filtration, sedimentation and finished water turbidity monitoring; municipal pipe network of water quality monitoring; industrial process water quality monitoring, cooling water, activated carbon filter water, membrane filtration water and the like. Features and benefits: ● online turbidity meter is set within the patent system to eliminate air bubbles ● cleaning and maintenance very simple; a three-month correction ● Online turbidity reproducible, independent of sample flow rate and pressure ● The 0 and 20NTU two-point calibration method - Recommended correction method ● You can also do a single point calibration by comparing: (optional range within 1-40NTU point) ● Online turbidity measurement units: NTU; at the same time there are a variety of auxiliary unit of measurement: FTU, TE / F, mg / L ● ??USEPA (EPA) approved methods online turbidity meter Technical indicators online turbidity meter range: 0.0001-9.9999; 10.000-99.999NTU; online turbidity meter automatically selects the range accuracy: 10 ~ 40NTU, the reading of ± 2% or ± 0.02, whichever is greater 40 - when 100NTU, ± 5% of reading Reproducibility: better than ± 1.0% of reading or ± 0.002, whichever is greater online turbidity meter response time: step response, the initial response was one minute, 15 seconds interval in response to the signal averaging: 6,30,60,90 sec user selectable; user default is 30 seconds sample flow rate: 200 ~ 750mL / min online turbidity meter Operating temperature: For a single sensor system is 0 ~ 50 ℃, for a two-sensor system is 0 ~ 40 ℃ sample temperature: 0 ~ 50 ℃ Analog Output: 0/4 ~ 20mA optional. In the range of 0 ~ 100NTU programmable relay: 3 SPDT, 230VAC, 5A; can set point alarm line Turbidimeter Power requirements: 100 ~ 230VAC, 50 / 60Hz, automatic selection; 40VA water pipes: 1/4 " ; NPT female thread 1/4 "; compression fittings (supplied) drains: 1/2"; NPT thread, 1/2 "; hose (supplied) Digital Communication: MODBUS / RS485, MODBUS / RS232, LonWorks protocol (optional) Standard methods: Standard Method 2130B, USEPA 180.1, HACH method 8195 online turbidity meter enclosure: NEMA-4X / IP66 controller Size: Turbidity: 25.4 × 30.5 × 40.6cm machine orders with sc200 controller 2976800 The 1720E turbidity probe cable length 2 m, 20NTU of STABLCAL standard solution with sc200 controller 2978100 (single, 220V) of the 1720E turbidity probe cable 2 m long, 20NTU of STABLCAL standard solution with sc200 controller 2976900 (dual-channel, 24V) of the 1720E turbidity probe length of 2 m, 20NTU of STABLCAL standard solution with sc200 controller 2978200 (single, 24V) of the 1720E turbidity probe length of 2 m, 20NTU of STABLCAL other standard solution Communication output numbers, refer sc200 ordering optional accessories 57960-00 25ft. (7.7 m) extension cable 46308-00 Power Cord (230VAC), with a waterproof plug. (NOTE: The power cord must be ordered separately) 52250-00 20NTU, ICE-PIC check module 52215-00 1NTU, ICE-PIC check module 26601-53 20.0NTU, 1L STABLCAL calibration, calibration standards 26598-53 1.0NTU , 1L, STABLCAL calibration, the calibration standard 44156-00 FORMAZIN calibration kit (including 4000NTU Formazin (500mL), TenSette pipette calibration barrel) 2461-49 Formazin standard solution, 4000NTU, 500mL 44153-00 calibration barrel, 1L (Note: Calibration barrels must be ordered separately) single turbidity probe 60101-01 1720E turbidity probe with cable length of 2 meters Reagents: Item Applicable Instrument Model parameter specification electrode solution category parameter model 2659853 1720E Low Range Turbidimeter Online ; 2100Q Portable Turbidimeter standard turbidity 1.0NTU 1L 246149 1720E Low Range Online turbidimeter; SS7 High Range Online turbidity; Accu4 / T53 low-range turbidity line analyzer; 2100Q Portable Turbidimeter Turbidity standard solution 4000NTU 500mL Accessories: Item Instrument Model measurement parameters described Chinese online 1895000 1720E Low Range Turbidimeter Turbidity Turbidity detector lights 5218000 1720D 1955400 1720E Low Range Online Turbidity Turbidity lamp 6012000 1720E Low Range Online Turbidity Turbidity Enlarge plate 5203100 1720E Low Range Online Turbidity Turbidity enlarged board 4500400 1720E Low Range Turbidimeter Turbidity online source T53A2020002 1720E Low Range Turbidimeter Turbidity T53 Live Power Board 6013800 1720E Low Range Online Turbidity Turbidity light cable 5206900 1720D turbidity cable Miss Liu phone / QQ: 18012620087 Tel: 0512-81661006 Mail: sailiwei99@126.com
Contact Detail
Company Name: | Suzhou Saili Granville Equipment Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Miss Liu() |
Telephone Number: | 0512-81661006 |
Company Address: | Suzhou, Suzhou , Jiangsu Province, China |
Zip/Postal Code: |
Find More Related Products
- Hash sensION + Series Teste..
- Hash sensION + Portable PH1..
- Which Baoji good make-up sc..
- Explosion-proof air sampler..
- Laboratory Portable Sampler
- LPG sampler
- Jinan album design album de..
- Shanxi CCZ20 type mine dust..
- Shanxi CCZ2 type of individ..
- FW-2 type mine high vacuum ..
- Belt Sampler - Redgate cent..
- Redgate particulate sampler..
- LB-901B type COD rapid dige..
- Differential pressure LB-80..
- Guoqiang JCB4A Methane Dete..
- Guoqiang GJG10.GJG100 metha..
- Guoqiang CCZ20 Mine dust sa..
- Leading! Switzerland RFbeam..
- Redgate Sampler - powder au..
- Sampler - Belt Sampler - Na..
- Sampler