Home
Products
Medical Rehabilitation Division of disease-specific medical infrared imaging system - sub detector
Medical Rehabilitation Division of disease-specific medical infrared imaging system - sub detector
Medical Rehabilitation Division of disease-specific medical infrared imaging system - sub detector
Medical Medical Infrared Medical thermal imager infrared imaging ZR-2010 [hereinafter referred to as ZR-2010] is a set of medical technology, infrared imaging technology, electronic technology and computer image processing technology of high-tech products. It uses advanced uncooled focal plane array as a detector without refrigeration, easy to use and fast, image clarity, high temperature resolution. ZR-2010 is dedicated to the distribution of human thermal field recording, dynamic and objectively monitor changes in the heat distribution of the body due to the functional changes caused analyzed by software that comes with relatively achieve thermal diagnostics, heat measurement, heat study function for clinical diagnosis, treatment, care, prevention of thermal field changes to provide objective information. China Beijing Sino-Swiss medical technology limited liability company Beijing Rui Hua Xia Healthcare Technology Co., Ltd. Beijing Sino-Swiss medical technology limited liability company China 1.022 China Beijing Sino-Swiss medical technology limited liability company ZR-2010 digital medical infrared camera - compact -A type classification: ZR-2010 digital medical infrared camera - small Published: 2014-09-05 08:58 ZR-2010 medical infrared imaging [hereinafter referred to as ZR-2010] is a set of medical technology, the infrared Imaging technology, electronic technology and computer image processing technology of high-tech products. It uses advanced uncooled focal plane array as a detector without refrigeration, easy to use and fast, image clarity, high temperature resolution. ZR-2010 is dedicated to the distribution of human thermal field recording, dynamic and objectively monitor changes in the heat distribution of the body due to the functional changes caused analyzed by software that comes with relatively achieve thermal diagnostics, heat measurement, heat study function for clinical diagnosis, treatment, care, prevention of thermal field changes to provide objective information. Suitable for human thermal image temperature to assist in the diagnosis of lumbar disc herniation and waist-hip petrified tissue injury tissue damage borne disease. ZR-2010 measurement has the following features: 1. high-definition images: The device uses 324 × 256 uncooled infrared detectors, infrared image more sophisticated, more clearly. 2. Temperature high resolution and accuracy: Temperature resolution of up to 0.05 ℃, measurement accuracy of ± 0.4 ℃, using blackbody calibration technology to improve the human body temperature measurement accuracy and repeatability. 3. Application software is powerful: Temperature and application software that comes with a good user interface, with a variety of medical body temperature measurement function, can store image information with data for analysis and comparison, convenient operation. The unique diagnostic system to assist diagnosis: equipment were equipped with traditional Chinese medicine theory supported by infrared thermal imaging technology expert diagnostic system is based on the results issued by the diagnosis. 5. Disease surveillance quick, simple: the device does not produce any radiation detection, without marking the drug, checking non-contact, painless, non-invasive, for both doctors and patients did not have any injuries and side effects, namely the investigation that is the fruit, is the real "green instrument . " 6. Check the wide range of applications: Where the heat changes caused by human tissue diseases can be checked with its wide range of applications, high clinical value. 7. Environmental adaptability: wide operating temperature range of the device, on the use of environmental requirements low, good adaptability. 8. Easy to use: The device can be a long, uninterrupted stability, low subsequent use cost, easy to move. Infrared thermography general health assessment system applications: 1, sub-health state detection: through metabolic heat intensity difference and variation in human cells, the use of Chinese medicine theory and clinical experience overall dialectical outlook on medicine, on the human body systems and overall sub-health status Comprehensive assessment. 2, early warning screening for major diseases: observation of the immune system, the endocrine system and the local organs of their respective regional lymph node abnormalities, early detection of cardiovascular, hypertension, cancer and other major disease risks. 3, women breast screening: infrared thermal imaging technology is recognized worldwide as the most safe and effective breast cancer risk sensitive side census, the census one case of breast, from image acquisition to analysis in just 10 minutes to complete. 4, male and female special inspections: special inspections for male and female reproductive systems and sexual function status. 5, Chinese medicine physical identification, syndromes, Meridian evaluation. 6, painful disease screening: can headache, neuralgia, joint pain, neck and back pain, leg pain and other pain disorders screening. 7, inflammation of warning: can the various parts of rhinitis, sinusitis, inflammation of the mouth, throat, thyroid gland inflammation, upper respiratory tract infection, pneumonia, cholecystitis, appendicitis, gastroenteritis, pancreatitis, prostatitis, gynecological inflammation and other body Superficial inflammation early warning. 8. Check in peripheral nerve disorders: a variety of migraine, crest cord injury, facial paralysis, facial spasm, trigeminal neuralgia. 9, early diagnosis and treatment of blood circulation disorders observed: cerebral vascular disease, cardiac insufficiency, thrombosis obliterans, varicose veins, diabetes and so on. 10, examine the efficacy of skin disease observe: Check burns and frostbite area and depth, finger (toe) replantation, graft efficacy was observed. 11, sub-health intervention assessment: Recuperation administered sub-health intervention techniques and eating health food (drugs) for the assessment of the effects of analysis to determine the best intervention programs. ZR-2010 digital medical infrared imaging - Small -A type index name ---- ZR-2010-type configuration details Temperature resolution: 0.025 ℃ imaging speed (frame time): about 25 frames / second infrared detector: 324x256VOx temperature range: 0 ℃ ~ 100 ℃ Focus Mode: computer-controlled motorized focus; software control from 1 to 4 times digital zoom; focus locking function Detector type: Uncooled vanadium oxide infrared focal plane array detector operating band: 7.5 ~ 13.5μm pixel size: 25μm temperature sensitivity: ≤50mk @ 25 ℃, under the conditions with F1 infrared camera image frame rate: 25Hz External Communication Interface: 100M full-duplex Ethernet Power Interface: DC9V-18V Lens: 35mm focal length, F number of 0.8, an electric Focus software systems: Infrared thermal imaging acquisition / processing / analysis software package intercom system diagnosis: two-way intercom system mainframe: high with the host computer display brands: Philips 19S4 19 inch printer: color inkjet printer radiation: The device only passively absorb infrared emitted by an object, the human body without any radiation ZR-2010 A type of small space requirements: patients simply provide a separate long 4 meters wide and 2 meters of space station into the infrared camera can, IR console placed outside it, usually do simple cut apart, they can be in the same room. Camera console: No lift height is 100cm, rose the most height of 180cm, with a high infrared lens rotated 180 °, 10 ° to move the camera up and down; moving back and forth rail 45cm, full infrared image taken no dead ends. ZR-2010 digital medical infrared imaging - Small -A type
Contact Detail
Company Name: | Beijing Dong Fang Fuxin Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Liu(Sales manager) |
Telephone Number: | 010-57118353 |
Company Address: | Dongcheng District, Beijing Dongzhimen Avenue 18 Good, Beijing, Beijing, China |
Zip/Postal Code: | 100011 |
Find More Related Products
- Infrared gas analyzer / flu..
- ESR analyzer
- Changsha, the largest furni..
- Xinghua plastic runway whol..
- Chengdu to Shenmu shipping ..
- AUTO5-1 Handheld five compo..
- How much pain acupoint Miao..
- Top Ten hospital treatment ..
- Southwest Guizhou bulk of t..
- New Zealand milk / toys / b..
- Domestic direct sales of in..
- Germany and Germany plans t..
- Power Quality Analyzer
- Infrared Analyzer
- Jing Fang root Cytokines ho..
- Fluoride ion F- test kits f..
- Dual-made industrial dissol..
- Win industrial dissolved ox..
- Industrial Conductivity Met..
- Industrial dissolved oxygen..
- Jinan epoxy floor paint man..