Hash TitralabTIM856 automatic potentiometric titrator
Hash TitralabTIM856 automatic potentiometric titrator
|
Ang Suzhou Instrument Co., Ltd. Contact: Gu Ling Tel: 15616451924 0512-88188156 E-mail: 792907@qq.com Company Website: www.zhongang.net TitraLab TIM854 / TIM856 automatic titrator Wing stop titration: customized precision potentiometric titration instrument! Pharmaceutical and biotechnology: antacids neutralizing capacity, antacids reaction time, enzyme activity (lipase, esterase, protease, cholinesterase) Agriculture & Food: Agricultural limestone dissolution rate, animal feed and detergent chemical dissolution characteristics: Wing Stop temperature of the reaction, the rate measured kinetics, soap bubbles activity intelligent design is set Maintenance-saving - saving time and effort all of the electrodes and the reagent tube with thorn-of-concept installation to ensure safety and reliability. Installation and maintenance is very convenient, single-module installation time-saving Buret. Step by step instructions interface - follow the onscreen instructions TIM854 and TIM856 Titration administrators display clear text display, measurement operation as simple as dealing with daily affairs. Titration curve display and includes a sensor and titration status. Single button to select preprogrammed functions make titrations count so simple - only one button TIM854 and TIM856 provides immediate landing routine functions, making TIM865 very simple to use. Preset regular features guide users to analyze, repeat testing and maintenance. TIM854 and TIM856 allow users to automatically sequence and repeat measurements - ideal for direct measurement of the connection, and set the end of the reagent pH by pH-stat titration. Predefined electrode and reagent saving time and effort. High resolution, unique PID and AAA calculation to ensure accurate results are summarized and - first time to obtain the correct result burette TIM854 and TIM856 is the highest resolution on the market and unrivaled pH / mV Wing stop titration. Strong or acid buffer samples, or in single or multi-step sequence can be fast and reliable analysis either. Whenever you analyze, titration can quickly reach the set point and do not have any risk. Experimental requirements of one or two-channel Wing stop titration - including all options TIM854 perform single-channel kinetics of enzyme permanent stop titration or permanently stop temperature control synthesis experiments. TIM856 extended application two channel Wing stop titration, and select the appropriate burette according to pH / mV reading, continuous reagent tubes to add continuous reagent addition, and the synthesis of crystal growth. The modular concept allows users to future expansion needs of the future - ahead of plan TIM854 and TIM856 some on multiple interfaces are standard, using Radiometer converter can sample the sample from 10 to 126. Multifunction ABU52 double Buret system to increase 4 additional burettes and 4 sensor inputs and two additional sample holder. By connecting the standard PC keyboard and barcode reader enables easy data input. Use TitraMaster 85 computer software available unlimited storage capacity. TitraLab: a complete and reliable solution immediately all of the following composition can form a functional workstation ■ A multi-functional modern pH titration titrator never stopped administrator ■ One or two high-resolution burettes have multiple volumes ■ Two optional sensors input for pH or mV potentiometric titration, one for imposed current titration and a differential measurement mode ■ A titration stand with 5-400ml beaker and an optional magnetic stirrer or stirring blade ■ One or two reagent bottle holder for reagent bottle placed in safety ■ complete accessories and cables to complete titration workstation installation Typical applications - pH Wing stop titration for standard volume 8-100ml - pH Wing stop titration for micro-volume technical parameters 0.5-9ml potentiometric titration method - endpoint titration: 1-4 preset titration end - forever stop technology: Stat-PID, proportional integral derivative dead-stop titration, for little or no buffer sample; Stat-AAA: addition calculation adapt Wing stop titration, important buffer capacity; Stat-temp: The sample temperature reagent rule - never stop titration modes: TIM 856 TIM 854 and a channel stop titration Wing - Wing stop titration modes: TIM 856, the second channel never stop titration, two reagents, According pH / mV value using an appropriate burette; continuous Wing stop titration, single group reagent burette continuous use does not interfere; Integrated Wing stop titration, two reagents, burettes operate simultaneously - Wing stop titration Titration: pH, mV, ml, IP inflection number, time - Titrant addition: continuous dynamic - reagent - Titrant calibration - pH electrode calibration: IUPAC standards using a five-point calibration, or 4-7-10 Series buffers, automatic buffer recognition - Direct pH / mV measurement with a stable reading record - back titration, manual or automatic reagent addition --10 ways to order - coupled with a 2-8 beaker method Range Resolution: -9 - + 23pH, 0.002pH; -2000 - + 2000mV, 0.1mV; -10 - + 100 ℃, 0.1 ℃ printout: automatic three levels of detail, optional: None, 80, in a row, by page titration curve: Volume - Time, mV / pH- time, temperature - time measurement results : maximum slope, average slope, volume and preset volume preset time period of the reaction rate calculation; 6 dead-stop titration plus 2 user-defined equations; 4 Wing stop titration results and 2 user-defined equations; optical alarm QC inspection Results; statistical calculations - measurement units: standard solution / sample / results all standard units, user-defined unit - Storage capacity: Full password protected programming landing, nonvolatile memory, 5000 / curve, pre-programmed method group, the user program 50, 30 sensors and 30 reagents with custom ID and type to help programming, 200 store the results. Embedded electrode and reagent replacement procedures, automatic electrode, reagent calibration and QC prompt - sample list: Up to 126, according to data with a digital ID, QC sample definitions - electrode holder - Stirring: magnetic stirrer (0-1100rpm), Stirring connection. Small cup volume: 5-400ml - Buret: TIM854- an embedded Buret, TIM856- two embedded burette burette volume Optional: 1,5,10,25,50ml, titration motors: 18,000, in line with ISO / FDIS 8655 -3, Burette extension: 4 (connection ABU52), UV protection syringe, embedded burette replacement and bubble removal procedures, cleaning, filling and emptying functions - Inputs and outputs: two instructions and a reference electrode input, optional polarity of the input: ± 1mV, DC or AC, differential and temperature inputs, 0-5V and 0-12V TTL output 0-5V TTL input, serial: printer / PC, sample changer, balance, TitraMaster85 PC software, use ABU52 increase 4 additional burette and electrode inputs, PS / 2 ports: a keyboard and / or bar code reader master plan General Information housing package: 128 * 128 dot LCD display, soft keypad (silicone) Size & Weight: 380 * 230 * 450mm (excluding pipeline), 5Kg (excluding reagent bottles) Power supply: 115 / 230VAC, 47-63Hz international standards: CE Certification: EMC 89/336 / EEC, LV 73/23 / EEC, cETLus: ITS / SEMKO UL Standard 61010A-1 CSA standard: C22 2 No.1010.1-92; RFID comply with R & TTE and FCC part 115 standard environmental conditions: 5-40 ℃, 20-80% RH Ordering Guide TitraLab system TitraLab 854 / xx or TitraLab 856 permanent blackout Titration Workstations, including: TIM854 pH / EP / Stat single burette titrator or TIM856 pH / EP / Stat double burette titrator, single or double burette with all connecting lines and luminal attachments, and one or two xxml Buret Optional heated beaker for standard or other order accessories which trace the volume of the specific needs of titration analysis, and the opposing electrodes and other accessories, please consult Aung Instrument Co., Ltd. in Suzhou.
Contact Detail
Company Name: | Ang Suzhou Instrument Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Gu Ling(Sales) |
Telephone Number: | 0512-88188156 |
Company Address: | Suzhou Wuzhong Economic Development Zone, Wang Wu Road 44-46 2, Suzhou , Jiangsu Province, China |
Zip/Postal Code: | 215128 |
Find More Related Products
- Supply METTLER titrator
- Automatic potentiometric ti..
- Alxa League fruit fried ice..
- Supply TP432 automatic titr..
- Industrial oxygen analyzer ..
- Imports of US BeadRuptor24 ..
- Quanzhou authority which ho..
- Chi Chi broker 18620555299
- Jingzhou to Hakusan logisti..
- AUT-701日本 DKK autoburette
- Japan DKK-TOA AUT-701 autom..
- ABT-511 automatic titrator ..
- Beijing factory TP432 autom..
- Feed detection equipment di..
- Welding the three-dimension..
- Ash melting characteristics..
- Tests coal plastic layer me..
- Where coal ash fusible test..
- Molybdenum ore elemental an..
- Tungsten ore Analytical Ins..
- Boron stone analytical inst..