Supply coking plant coal tar measurement 2010TD flange type level transmitter
Supply coking plant coal tar measurement 2010TD flange type level transmitter
2010TD Level Transmitter Applications Multi Vision 2000T series transmitters used in industrial processes a full range of differential pressure, pressure, absolute pressure measurement with analog or digital output signal. 2010TD level transmitter is a high-performance measurement instruments, by mounting flange level transmitter can be installed directly on the test tanks, tanks of all kinds of precision measurement of differential pressure and level. When measuring media with a high temperature, high viscosity, corrosive ingredients and there is a tendency during polymerization, Level Flange isolation process and the transmitter body. Level Flange according to DIN or ANSI standard, connecting rich form. Process wetted parts can choose different materials, such as stainless steel, Hastelloy C or tantalum, depending on corrosion resistance requirements. 2010TD level transmitter with a complete range of all kinds of fill fluid, such as suitable for food and pharmaceutical industry vegetable oil. 2010TD level transmitter measuring range (when not migrate) to 0-1kPa ~ 10MPa, Level Flange rated pressure was 1.6 / 4MPa, 6.4MPa, 10MPa, Class 150, Class 300 and Class 600. Works 2010TD level transmitter, the structure consists of 2010TD differential pressure transmitter and remote seal means --- Level Flange mounted directly composition, 20 10TD principle of differential pressure level transmitter with 2010TD change the same transmitter, see 2010TD differential pressure transmitter, but positive pressure side (⊕) pressure transmission path is slightly different: the role of the high-pressure side of the differential pressure, first of all by the level of the flange isolating diaphragm and tank filling, and then After the transmitter body, and finally to the high-pressure side measuring sensor. When, for example 3) 2010TD differential pressure transmitter V15712- V15712- Communication 4-20mA / HART PROFIBUS-PA HPH measurement range (not migrated 2010TD level transmitter selection of the size spectrum of basic selection Code Option Code Selection) 2 ) 0-1kPa ~ 6kPa 0-4kPa ~ 40kPa 0-25kPa ~ 250kPa 0-200kPa ~ 2MPa 0-100kPa ~ 10MPa BCDEGC absolute pressure sensor range (mandatory) 4 1 A diaphragm Hastelloy C tank filled silicone A process flanged threaded hole location, high and low side of the same material rated pressure 10MPa 1 316 stainless steel process connection and drain / vent valve (supplied with bulkhead) CNPT 1/4 threaded flange rear side of the upper end surface (only together with the code 395 use) Lower side (use) only in conjunction with the code 395 CDF Level Flange (positive pressure side) 2) EE bolted flange O-ring 7 stainless steel nitrile rubber fluorine rubber (temperature limits: -20 ~ + 120 ℃) ??poly tetrafluoroethylene (Pn≤25MPa, operating temperature ≥-20 ° C) 7 6 8 amplifier shell type material Electrical connection D horizontal shell (Barre-type) is not within the nameplate aluminum viscose thread NPT 1/2 a M20 × 1.5 cable DE horizontal seal buckle housing (Barre-type) is not adhesive plate stainless steel (not optional in-place buttons 5C2) NPT 1/2 internal thread J horizontal shell (Barre-type) is not within the nameplate aluminum viscose thread NPT 1/2 A * functions place the square root of 224 amplifier shell attachment button (not applicable housing code J) LCD meter backlit LCD meter (only HART communication) transient overvoltage protection (not applicable to the explosion-proof case) 5C2 5C4 5C5 5C6 5C2 5C4 proof Ex dIICT6 (without cable seal buckle) Ex iaIICT6 (Profibus: Ex iaIIB / IICT6) 5A1 5A3 drain / vent valves stainless steel 395 395 process flange joints (material: kidney-shaped flange / screw) Slotted Flange NPT 1/2 (stainless steel / carbon steel) Slotted Flange NPT 1/2 (stainless steel / stainless steel) M20 × 1.5 threaded joint 376 377 C21 digit number written on the nameplate (up to 30 characters) stainless steel plate (up to 30 characters) 205 5C8 Instructions English Chinese Z2E Z2C Z2C English nameplate nameplate nameplate Chinese ECC Note: 1) measuring range of level transmitter should be considered and level transmitter body flange, in order to make the best transmitter performance Excellent, recommended to choose turndown ratio ≤10: 1. 2) Process Connection Code E option in addition to the positive pressure side, the suction side should be selected from the C, D or F. 3) option is not selected, choose one or more selected. 4) Selection example: 2010TD level transmitter body Order number: V15712-HC1A1EC7D / 5C2 / 5C4 / 395 / Z2C / C DN 50 / DN 2 "; Flat / Male Level Flange 1) Option Basic Option Type Code Option Code Selection example 3) remote seal is installed directly (without capillary) ⊕ 729 ⊕ side side seal facial mask nominal diameter of 729 pieces / sealing surface material DN 50 (DIN 2501) E-type (DIN 2526) 316L stainless steel ( not recommended) Hastelloy C Tantalum DN 2 "; (ANSI B 16.5) RF type (ANSI B 16.5) 316L stainless steel, Hastelloy C Tantalum P00 P01 P02 P09 P10 P11 P09 flange rated pressure 2) DN 50 (DIN 2501 ) PN1.6MPa / 4MPa (not recommended) PN6.4MPa PN10MPa DN 2 "; (ANSI B 16.5) Class 150 Class 300 Class 600 P30 P31 P32 P33 P34 P35 P33 flat / plug-in flat plug-in (but not" Tantalum "of diaphragm material) plug-in, 316L stainless steel insert length 50 mm insert length 100 mm length 150 mm plug is inserted, Hastelloy C insert length 50 mm insert length 100 mm insert length 150 mm P50 P51 P52 P53 P54 P55 P56 P50 fluoro silicone oil fill fluid vegetable 074687673074 flange attached to polyethylene film diaphragm FEP film F46 Note: 1) for the rated pressure, the material, the sealing surface, other options can be specified requirements of the tank was filled. After the three-digit code bits flange transmitter body added to the order number, with the oblique crossed separately. 2) Select the Level Flange pressure rating should be greater than the maximum range of the transmitter body selected. 3) Selection example: DN 2 "; the flat level flange Order number: / 729 / P09 / P33 / P50 / 074 DN 80 / DN 3"; Flat / Male Level Flange 1) Option Base selection code Option Code Selection example 3) remote seal is installed directly (without capillary) ⊕ 729 ⊕ side side seal facial mask nominal diameter of 729 pieces / sealing surface material DN 80 (DIN 2501) E-type (DIN 2526) 316L stainless steel (not recommended Use) Hastelloy C Tantalum DN 3 "; (ANSI B 16.5) RF type (ANSI B 16.5) 316L stainless steel, Hastelloy C Tantalum P12 P13 P14 P21 P22 P23 P21 flange rated pressure 2) DN 80 (DIN 2501) PN1 .6MPa / 4MPa (not recommended) PN6.4MPa PN10MPa DN 3 "; (ANSI B 16.5) Class 150 Class 300 Class 600 P36 P37 P38 P39 P40 P41 P39 flat / plug-in flat plug-in (but no" Tantalum " Material diaphragm) plug-in, 316L stainless steel insert length 50 mm insert length 100 mm length 150 mm plug is inserted, Hastelloy C insert length 50 mm insert length 100 mm insert length 150 mm P50 P57 P58 P59 P60 P61 P62 P59 filling Liquid silicone fluorine oil vegetable 074687673074 flange attached to polyethylene film diaphragm FEP film F46 Note: 1) for the rated pressure, the material, the sealing surface, filling the tank of other options can be specified requirements. After the three-digit code level flange transmitter body added to the order number, with the oblique crossed separately. 2) Select the Level Flange pressure rating should be greater than the maximum range of the selected transmitter body. 3) Selection example: DN 3 "; plug-Level Flange Order number: / 729 / P21 / P39 / P59 / 074 DN 4"; flat / Plug-Level Flange 1) Option Base Selection Code Option Code Selection Example 3) remote seal is installed directly (without capillary) ⊕ side nominal diameter W90 W90 ⊕ side seal facial mask sheet / sealing surface material DN 4 "; (ANSI B 16.5) RF type) 316L stainless steel, Hastelloy C Tantalum W01 W02 W03 W01 flange rated pressure 2) DN 2 "; (ANSI B 16.5) Class 150 Class 300 W04 W05 W04 flat / plug-in flat plug-in (but no" Tantalum "of diaphragm material) plug-in, 316L length 50 mm stainless steel insert insert insert length 100 mm length 150 mm insert, Hastelloy C insert length 50 mm insert length 100 mm insert length 150 mm W06 W07 W08 W09 W10 W11 W12 W09 fluoro silicone fill fluid vegetable oil 074 687 673 074 flange attached to polyethylene film diaphragm FEP film F46 Note: 1) for the rated pressure, the material, the sealing surface, filling the tank of other options can be specified requirements. After the three-digit code level flange transmitter body added to the order number, with the oblique crossed separately. 2) Select the Level Flange pressure rating should be greater than the maximum range of the selected transmitter body. 3) Selection example: DN 4 "; flat level flange Order number: / W90 / W01 / W04 / W09 / 074
Contact Detail
Company Name: | Henan Rip Control Technology Co., |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. WANG Hong-juan(Sales Business Manager) |
Telephone Number: | 0136-63857969 |
Company Address: | Zhongyuan District 49, Zhengzhou City, Henan Province, China |
Zip/Postal Code: | 450006 |
Find More Related Products
- Tangshan cold ammonia leak ..
- Pressure Transmitter supply..
- Fuzhou York central air con..
- Turbine flowmeters OEM manu..
- Brand alarm acetylene gas a..
- Chengde gas leak alarms, co..
- Lurie Electronics (FIG), pu..
- Supply water purifier sales..
- v-cone flowmeters meter OEM..
- Flowmeter orifice flowmeter..
- TD2100-4T0370S low sales
- Three-phase AC voltage tran..
- LWGB-6
- ELETTA flowmeter
- Formica HPL veneer | Shando..
- Collapsible hanger processi..
- Germany Bo passers-boiler, ..
- Electromagnetic Flowmeter
- WESTLOCK Locator
- Shipping Italian PAVONE wei..
- Supply LWBT series of fire ..