Supply of industrial site pipeline pressure differential pressure transmitter for measurement 2010TD

Supply of industrial site pipeline pressure differential pressure transmitter for measurement 2010TD
Supply of industrial site pipeline pressure differential pressure transmitter for measurement 2010TD
Supply of industrial site pipeline pressure differential pressure transmitter for measurement 2010TD

Larger photo of automa dispenser

Company:Henan Rip Control Technology Co.,
Information Name: Supply of industrial site pipeline pressure differential pressure transmitter for measurement 2010TD
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
2010TD differential pressure transmitter applications Multi Vision 2000T series transmitters used in industrial processes a full range of differential pressure, pressure, absolute pressure measurement with analog or digital output signal. 2010TD Transmitter measures differential pressure, flow or level. 2010TD transmitter measurement range (when not migrate) to 0-50Pa ~ 10MPa, rated pressures of 0.6MPa (only differential pressure), 16MPa, 25MPa or 40MPa. Works transmitter uses advanced composite micro silicon solid-state sensors, modular design, the adaptation unit with integrated electronics and a sensor module with push button control unit amplifier. Fully welded sensor module is a dual-chamber system with a holistic overload diaphragm, an internal absolute pressure sensor and a silicon differential pressure sensor. Absolute Pressure Sensor feel only the high-pressure side (⊕) pressure, static pressure as a reference value compensation. Differential pressure sensor connected via a capillary suction side and suction side transmitter / vacuum reference cavity. Measured differential pressure / pressure absolute pressure tank filled by the isolation diaphragm and transmitted to the silicon pressure sensor and detection diaphragm. Small diaphragm displacement detection result in the detection system output voltage changes, the output voltage of the differential pressure is proportional to the adaptation unit and the amplifier into a standard output signal. 2010TD differential pressure transmitter type spectrum selection Basic selection Code Option Code Selection example 3) 2010TD differential pressure transmitter V15712- V15712- Communication 4-20mA / HART PROFIBUS-PA HPH differential pressure / sensor measurement range (not migrate When) 2) 0-50Pa ~ 1kPa (rated pressure 0.6MPa) 0-200Pa ~ 6kPa 0-400Pa ~ 40kPa 0-2.5kPa ~ 250kPa 0-20kPa ~ 2MPa 0-100kPa ~ 10MPa ABCDEGC absolute pressure sensor range 40MPa (2010TD will Option) (For A range code is 0.6MPa) 1 1 measuring sensor diaphragm tank filling A Hastelloy C silicone A process flange, high and low pressure side of the same material rated 1316 stainless steel 16MPa 25MPa 40MPa 0.6MPa (1kPa range) 1 2 3 E process connection and drain / vent screw hole locations (supplied with bulkhead) in the C NPT 1/4 threaded flange rear end face of the upper side (only with Code 395) lower side (only with Code 395 used together) CDF bolted flange O-ring 7 stainless steel nitrile rubber fluorine rubber (temperature limits; -20 ~ + 120 ℃) ??polytetrafluoroethylene (Pn≤25MPa, operating temperature ≥-20 ℃) ??7 6 8 Amplifier Enclosure Type Material Electrical connection D horizontal shell (Barre-type) is not within the nameplate aluminum viscose thread NPT 1/2 a M20 × 1.5 cable gland buckle DE horizontal shell (Barre-type) is not adhesive plate stainless steel (not optional situ button 5C2) within NPT 1/2 internal thread J horizontal shell (Barre-type) stainless steel plate aluminum thread NPT 1/2 A * 2010TD differential pressure transmitter (option) 1) Option Base Selection Code Option Code Selection example 3 ) function square root accuracy 0.05% 224 5C9 amplifier shell attachment place buttons (not applicable housing code J) LCD meter backlit LCD meter (only HART communication) transient overvoltage protection (not applicable to the case of explosion-proof) 5C2 5C4 5C5 5C6 5C2 5C4 proof Ex dIICT6 (without cable seal buckle) Ex iaIICT6 (Profibus: Ex iaIIB / IICT6) 5A1 5A3 mounting bracket 2 "; tube bent bracket, curved steel wall mounting bracket, steel 2"; Tube flat bracket, Carbon Steel 2 "; tube bent bracket, stainless steel wall bent bracket, stainless steel 2"; Flat bracket tubes, stainless steel B01 B02 B03 B04 B05 B06 B03 drain / vent valves stainless steel (2) 395 395 process flange joints (material: kidney-shaped flange / screw) Slotted Flange NPT 1/2 (stainless steel / carbon steel) Slotted Flange NPT 1/2 (stainless steel / stainless steel) M20 × 1.5 threaded joint 376 377 C21 digit number written on the nameplate (up to 30 characters) stainless steel plate (up to 30 characters) 205 5C8 Instructions English Chinese Z2E Z2C Z2C English nameplate nameplate nameplate Chinese ECC Note: 1) option is not selected, choose one or more selected. 2) In order to make the best transmitter performance, we recommend selecting turndown ratio ≤10: 1. 3) Selection example: 2010TD differential pressure transmitter Order number: V15712-HC1A1C7D / 5C2 / 5C4 / B03 / 395 / Z2C / C 
Contact Detail
Company Name: Henan Rip Control Technology Co.,
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. WANG Hong-juan(Sales Business Manager)
Telephone Number: 0136-63857969
Company Address: Zhongyuan District 49, Zhengzhou City, Henan Province, China
Zip/Postal Code: 450006
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450