WRN-630 conical thermocouple protection tube station dedicated thermocouple
WRN-630 conical thermocouple protection tube station dedicated thermocouple
Thermocouple 1 power plant, for the application of professional power plant designed to meet the 300,000, 600,000 kilowatts generating units and auxiliary equipment required temperature. Direct measurement of the range of -200 ° C ~ 800 ° C of the production process of the liquid, vapor, gas and solid surface temperature. 2, the working principle of the thermocouple electrode composed of two different conductor materials. When measuring side and reference junction temperature difference, it will generate thermoelectric power, work thermoelectric power meter will show the corresponding temperature value. Thermal resistance is the use of material changes in temperature, its resistance changes with the characteristics to measure the temperature. When the resistance changes, the working resistance of the meter will show the corresponding temperature value. 3, the main technical parameters Product performance standards IEC584 IEC751 IEC1515 JB / T18622-1997 JB / T8623-1997 GB / T16839-1997 4, measuring range and tolerance Graduation number tolerance level I II Temperature range ° C Tolerance Value Tolerance Value Temperature range ° C WRN K ± 1.5 ° C -40 ~ + 375 ± 2.5 ° C -40 ~ + 333 ± 0.004ltl 375 ~ 1000 ± 0.0075 ltl 333 ~ 1200 WRM N ± 1.5 ° C -40 ~ + 375 ± 2.5 ° C -40 ~ + 333 ± 0.004 ltl 375 ~ 1000 ± 0.0075 ltl 333 ~ 1200 WRE E ± 1.5 ° C -40 ~ + 375 ± 1.5 ° C -40 ~ + 333 ± 0.004 ltl 375 ~ 800 ± 0.004 ltl 333 ~ 900 WRF J ± 1.5 ° C -40 ~ + 375 ± 1.5 ° C -40 ~ + 333 ± 0.004 ltl 375 ~ 750 ± 0.004 ltl 333 ~ 750 WRC T ± 1.5 ° C -40 ~ + 125 ± 1 ° C -40 ~ + 133 ± 0.004 ltl 125 ~ 350 ± 0.0075 ltl 133 ~ 350 5, temperature insulation resistance thermal resistance at ambient temperature of 15-35 ° C, relative humidity less than 80%, the test voltage of 10-100V (DC ) insulation resistance between the electrode and the jacket pipe> 100MΩ. Thermocouples at an ambient temperature of 20 ± 15 ° C, relative humidity less than 80%, the test voltage is 500 ± 50V (DC) between the electrode and the jacket pipe insulation resistance> 1000Ω.m Company name; Hayward blue Instrument Co., Ltd. Contact: Zhou Jianhua Tel: 0572-6069899 Mobile: 13867297390 Fax: 0572-6600672 Company Website: WWW.shwol .com mail: shwol1@126.com
Contact Detail
Company Name: | Hayward Blue Instrument Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Zhou Jianhua() |
Telephone Number: | 0572-6069899 |
Company Address: | Chongming, , Shanghai, China |
Zip/Postal Code: |
Find More Related Products
- How to eliminate stretch ma..
- Universities and Mineral co..
- PET blowing mold
- Manufacturers lights, light..
- Quality handheld lights, ha..
- LED lamp price protection, ..
- Turnout prices indicate lam..
- 35KV high-insulated rubber ..
- The thick insulation 10KV r..
- 35KV insulation rubber shee..
- Black insulating rubber mat..
- Red insulated 10KV rubber m..
- High voltage insulation car..
- PV component tester
- Qing sound chamber maintena..
- GB 10KV insulation rubber m..
- Rubber sheet rubber sheet h..
- Plant with insulating rubbe..
- Information to buy antistat..
- 3561 intelligent battery in..
- Water-cooled flat shunt shu..