Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Supply AT358 power quality monitoring instrument

Supply AT358 power quality monitoring instrument
Supply AT358 power quality monitoring instrument
Supply AT358 power quality monitoring instrument

Larger photo of automa dispenser

Company:Shenzhen Echo Reiter Detection Equipment Co.
Information Name: Supply AT358 power quality monitoring instrument
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Product Overview: power quality monitor is running the grid quality monitoring and analysis of the specific products that can provide electricity to run the power quality data voltage / current / frequency, phase unbalance, power / power monitoring and harmonic analysis. analysis, and equipped with large-capacity memory, the power grid can be a long period of data acquisition and monitoring, Internet / Intranet network-based remote monitoring software, you can upload the collected data B / S structure to the monitoring center, technical staff through networked computers, each monitoring point can be achieved centralized monitoring and power quality analysis and management. Design Features: ◆ have GPRS wireless transmission capabilities and an Ethernet remote transmission capabilities, real-time data can be learned at any monitoring points each, and through remote control technology, so that at any time for any one monitoring point to modify settings and doing special detection . ◆ AT358 can view the recorded data anywhere, at any time, and detailed in-depth analysis on a PC. ◆ If abnormal power event occurs, AT358 with the fastest speed alarm, and by the raw data can be quickly dealt with the problem of equipment and device location on the computer. ◆ company constantly improve monitoring terminal program, customers can remotely download and install, easy to update monitoring terminal program. ◆ built-in high-capacity Flash memory disks, you can ensure the integrity of the length of recording time and recording data. Product Features: ◆ power quality parameter monitoring functions: 1. to measure the three-phase three-wire, three-phase four-wire (three voltage and four current) voltage, current, frequency, and record the change in trend. 2. The measure phase four-wire power system phase active power, apparent power, reactive power, power factor, and record changes in the trend of three-phase active. Voltage and current imbalance 3. measure three-phase power system and record its trends. The measure three-phase voltage, and 2 to 25 times the fundamental harmonic current, and total harmonic distortion. And record where it's trends. 5. measure the voltage swell / sag and voltage fluctuations and flicker. 6. Capture grid transient (358A) ◆ System management functions: ● Data management Basic measurements: See the basic measurement functions stored in the resulting data. Harmonic data: See harmonic measurement function saved the resulting data. Power Data: View saved power measurement result. Unbalanced data: See Unbalanced measurements results stored data. OSCILLOGRAPHY Event Log: View the event recorder wave function saved the resulting data. ● Measurement Calibration Zero Calibration: zero calibration for each channel. Sensor Settings: Set the current sensor. It is advised to use the instrument to set the sensor type here is in agreement with the sensor actually used. ● System Setup Select language: Chinese / English. Time: Set the meter clock. ● Disclaimer View instrumentation software version information ● Software updates can be updated on the instrument upgrade technical indicators: measure the scope of the three-phase voltage measurement accuracy Description: 10 ~ 700V (rms) zero line voltage: 1 ~ 70V (really effective value) Voltage: ± 0.5% voltage / current / frequency three-phase current: 0 ~ (True RMS, matching current sensor) Current: ± 0.5% neutral current: 0 ~ (True RMS, matching the current sensor) Frequency : ± 0.01Hz Frequency: 40 ~ 70Hz here to A phase voltage frequency as the measuring frequency harmonic measurement voltage harmonics: THD, 1 to 50 times harmonic voltage harmonic: ± 0.1 (% f) current harmonics: Total Harmonics, 1-50 harmonic current harmonics: ± 1% Active Power Measurement: 0.05 ~ 700KW Active: ± 2% Apparent: 0.05 ~ 700KVA apparent: ± 2% Reactive: 0.05 ~ 700KVAR Reactive: ± 2% Power Factor: 0.00 to 1.00 power factor: reading ± 0.005 active energy: 0.01 ~ 10000kWh active energy: ± 2% Apparent power: 0.01 ~ 10000kVAh apparent energy: ± 2% Reactive power: 0.01 ~ 10000kVARh reactive energy : ± 2% average power factor: 0.00 to 1.00 average power factor: reading ± 0.005 Unbalanced fundamental voltage: 10 ~ 700V (rms) voltage: 0.5% Current: 0.5% of the fundamental current: 0.5 ~ (True RMS) Frequency: reading ± 0.01Hz fundamental frequency: 40 ~ 70Hz phase angle: reading ± 0.3 o phase angle: 0 ~ 360o voltage unbalance: ± 0.2 unbalance reading: 0.0% to 100% of the current imbalance : reading ± 0.2 here to A phase voltage frequency as total measured frequency monitoring and recording parameters can be recorded: three-phase voltage, recording duration = (instrument data can be recorded maximum three-phase current, neutral current, voltage harmonic number × save interval ) / instrument can record 60 minutes (total harmonic, harmonics 1 to 25), the maximum number of data retention time = 18 635 current harmonics (THD, harmonics 1 to 25), interval: 3S ~ 30MIN recording duration: 15 hours to 388 days phase unbalance, active power, power factor, volatility, flicker collection interval 3 seconds, it can monitor 15.5 hours, 30 minutes set the sampling interval can be monitored 388 days (three seconds to 30 When ± 5% Flicker Flicker short length: continuously adjustable points) voltage surges and sags swells, voltage dips and temporary power outages can record up to 40 events fluctuation of voltage fluctuation amount: 0.1% to 10.0% Measurement error Flicker short-term Flicker measurement error: ± 5% for a long time flicker measurement error: ± 5% digital oscilloscope phase voltage, phase current, neutral voltage and neutral current transient waveform maximum sampling frequency: 200KHz Minimum sampling frequency: 100Hz model AT358 size 225 × 155 × 150 memory 128M bit touch screen display, 5.7-inch 320 × 240 color graphic LCD supply voltage 14.4V (lithium battery) Communication interface GPRS / LAN Weight 2KG 
Contact Detail
Company Name: Shenzhen Echo Reiter Detection Equipment Co.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Ng(Regional Marketing Manager)
Telephone Number: 0755-26904787 0755-06904787
Company Address: A seat before 海路丽 Bay International, Nanshan District, Shenzhen 831, Shenzhen City, Guangdong, China
Zip/Postal Code: 518000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450