Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Used Anritsu MT8820C Tester sales leasing

Used Anritsu MT8820C Tester sales leasing
Used Anritsu MT8820C Tester sales leasing
Used Anritsu MT8820C Tester sales leasing

Larger photo of automa dispenser

Company:Haibo Xi test equipment Leasing Co., Ltd.
Information Name: Used Anritsu MT8820C Tester sales leasing
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Batch Measurement RF Test RF Tx test key measurements of LTE mobile terminal unit supports a key test RF Rx measurements excellent operability to reduce the number of production line testing and maintenance of MT8820A / B forward compatibility Parallelphone? Measurement Maximum input level: +35 dBm (main port 1) RF signal generator: Frequency range: 30 MHz to 2700 MHz (Setting range: 400 kHz to 2700 MHz) 3400 MHz to 3800 MHz (for an optional MT8820C-018) is set Resolution: 1 Hz output level level range:? 140 to 10 dBm (main port 1) ,? 130 至 0 dBm (auxiliary port 1) Resolution:? 0.1 dB Accuracy: Main: ± 1.0 dB, ± 0.7 dB (typ.) (output frequency ≥50 MHz), ± 1.5 dB (output frequency <50 MHz) (120 to 10 dBm, after calibration, 10o to 40oC??) Auxiliary: ± 1.0 dB, ± 0.7 dB (typ) (output frequency ≥50 MHz), ± 1.5 dB (output frequencies <50 MHz) (120 to 0 dBm, after calibration, 10o to 40oC??) W-CDMA Measurement (Hardware: Option 001 software: MX882000C, MX88205xC): Modulation Analysis Input Level:? 30 to +35 dBm (Main) Modulation Accuracy: (single-input single-DPCCH and DPDCH) ≤2.5% RF power input level:? 65 to +35 dBm (main) Accuracy: ± 0.3 dB (typ), ± 0.5 dB (? 25 to +35 dBm), ± 0.7 dB (? 55 to? 25 dBm), ± 0.9 dB (? 65 to? 55 dBm) * After calibration, 10o to 40oC measurement object : DPCH, PRACH bandwidth input level:? 10 to +35 dBm (main) Adjacent channel leakage power ratio input level:? 10 to +35 dBm (main) measuring point: ± 5 MHz, ± 10 MHz BER Measurement: insert PN9 or PN15 algorithm in the DTCH data measurements: BER, BLER call processing Call control: registration, start, stop, transfer, disconnected from the network, the terminal is disconnected (3GPP-compliant execution of each process and performed by / fail assessment) mobile terminal control: Output level, loopback (execution of each mobile terminal control 3GPP-compliant) modulation analysis input level:? 30 to +35 dBm (primary) modulation accuracy: ≤2.5% (input-single-DPCCH single DPDCH and) RF power input level:? 65 to +35 dBm (main) Accuracy: ± 0.3 dB (typ), ± 0.5 dB (25 to +35 dBm), ± 0.7 dB (55 to?? ? 25 dBm), ± 0.9 dB (65 to 55 dBm) * After calibration, 10o to 40oC measurement object:?? DPCH, PRACH bandwidth input level:? 10 to +35 dBm (main) Adjacent channel leakage power ratio input Level:? 10 to +35 dBm (main) measuring point: ± 5 MHz, ± 10 MHz Bit Error Rate Measurement: insert PN9 or PN15 algorithm in the DTCH data measurements: BER, BLER call processing Call control: registration, Start, termination, transfer, disconnected from the network, the terminal is disconnected (the execution of each process in line with 3GPP standards and performs pass / fail evaluation) mobile terminal control: Output level, loopback (execution of each mobile terminal control 3GPP-compliant) Modulation Analysis Input Level:? 30 to +35 dBm (Main) Modulation Accuracy: (single-input single-DPCCH and DPDCH) ≤2.5% RF power input level:? 65 to +35 dBm (main) Accuracy: ± 0.3 dB (typ), ± 0.5 dB (? 25 to +35 dBm), ± 0.7 dB (? 55 to? 25 dBm), ± 0.9 dB (? 65 to? 55 dBm) * After calibration, 10o to 40oC measurement object : DPCH, PRACH bandwidth input level:? 10 to +35 dBm (main) Adjacent channel leakage power ratio input level:? 10 to +35 dBm (main) measuring point: ± 5 MHz, ± 10 MHz bandwidth input Level:? 10 to +35 dBm (main) Adjacent channel leakage power ratio input level:? 10 to +35 dBm (main) measuring point: ± 5 MHz, ± 10 MHz Bit Error Rate Measurement: insert in the DTCH PN9 or PN15 algorithm data measurements: BER, BLER call processing Call control: registration, start, stop, transfer, disconnected from the network, the terminal is disconnected (the execution of each process in line with 3GPP standards and performs pass / fail evaluation) mobile terminal control : output level, loopback (execution of each 3GPP-compliant mobile terminal control) GSM / GPRS measurement: (hardware: Option 002 software: MX882001C) Frequency / modulation measurement input level:? 30 to +40 dBm (sudden The average signal power, the Lord) measurements: normal burst, RACH amplitude measurement input level:? 30 to +40 dBm (average power of the burst main) measurements: normal burst, RACH measurement accuracy: ± 0.3 dB (typ), ± 0.5 dB, ± 0.7 dB, * After calibration, 10o to 40oC linear (20 to +40 dBm?) (30 to 20 dBm??): ± 0.2 dB (0 to 40 dB,? ? ≥ 30 dBm) BER measurement functions: frames, bits and CRC error measurement measurement object: GSM based data uplink TCH loopback call processing serial data I / O port input from the rear panel GPRS establish upstream of the GPRS TCH call processing call control blocks received by the terminal: GSM (location registration, initialization, termination, network disconnection, terminal disconnection) GPRS (connect, disconnect, data transfer) Terminal Control: GSM (output level, slots, timing advance loop on / off) GPRS (test mode A, test mode B, BLER) CDMA2000 1X Measurement: (hardware: Option 003 software: MX882002C) bandwidth input level:? 10 to +35 dBm (main ) Adjacent channel leakage power ratio input level:? 10 to +35 dBm (main) measuring point: ± 5 MHz, ± 10 MHz Bit Error Rate Measurement: insert PN9 or PN15 algorithm in the DTCH data measurements: BER, BLER Call processing Call control: registration, start, stop, transfer, disconnected from the network, the terminal is disconnected (the execution of each process in line with 3GPP standards and performs pass / fail evaluation) mobile terminal control: Output level, loopback (execute each eligible 3GPP standard mobile terminal control) amplitude measurement input level:? 65 to +35 dBm (main) Accuracy: ± 0.3 dB (typ), ± 0.5 dB (25 to +35 dBm), ± 0.7 dB (?? ? 55 to 25 dBm), ± 0.9 dB (65 to 55 dBm) * After calibration, 10o to 40oC linear:?? ± 0.2 dB (0 to 40 dB, ≥ 55 dBm), ± 0.4 dB (0 to??? 40 dB, ≥ 65 dBm) Frequency / modulation measurement input level:?? 30 to +35 dBm (main) carrier frequency accuracy: ± (set frequency × reference oscillator accuracy +10 Hz) residual waveform quality:> 0.999 mistake rate measurement FER (Frame Error Rate) measurement: with service options 2,9,55 and 32 (TDSO) of FER measurements show items: confidence level, FER, error frame count, sampling frame count call processing bands: BC 0 to 12,14,15,18,19 Call control: Location registration, initialization, termination, disconnected from the network, the terminal is disconnected paging channel data rate: full rate RC configuration: F-RC1 + R-RC1, F-RC2 + R -RC2, F-RC3 + R-RC3, F-RC4 + R-RC3, F-RC5 + R-RC4 Supported protocols: IS-95B, J-STD-008C, ARIB T-53, Korean PCS, IS- 2000 (SR1) amplitude measurement input level:? 65 to +35 dBm (main) Accuracy: ± 0.3 dB (typ), ± 0.5 dB, ± 0.7 dB (55 to (25 to +35 dBm?)?? 25 dBm), ± 0.9 dB (65 to 55 dBm) * After calibration, 10o to 40oC linear:?? ± 0.2 dB (0 to 40 dB, ≥ 55 dBm), ± 0.4 dB (0 to 40 dB,??? ≥ 65 dBm) Frequency / modulation measurement input level:?? 30 to +35 dBm (main) carrier frequency accuracy: ± (set frequency × reference oscillator accuracy +10 Hz) residual waveform quality:> 0.999 bit error rate measurement FER (FER) measurements: FER measurement with service options 2,9,55 and 32 (TDSO) Showing items: confidence level, FER, error frame count, sampling frame count call processing bands: BC 0 to 12, 14 , 15,18,19 call control: Location registration, initialization, termination, disconnected from the network, the terminal is disconnected paging channel data rate: full rate RC configuration: F-RC1 + R-RC1, F-RC2 + R-RC2, F-RC3 + R-RC3, F-RC4 + R-RC3, F-RC5 + R-RC4 Supported protocols: IS-95B, J-STD-008C, ARIB T-53, Korean PCS, IS-2000 (SR1 ) 
Contact Detail
Company Name: Haibo Xi test equipment Leasing Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Li Shujuan()
Telephone Number: 021-67766350-8010
Company Address: Songjiang, , Shanghai, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450