Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Used HP8901B modulation analyzer instrument JMM2500 modulation table offset price

Used HP8901B modulation analyzer instrument JMM2500 modulation table offset price
Used HP8901B modulation analyzer instrument JMM2500 modulation table offset price
Used HP8901B modulation analyzer instrument JMM2500 modulation table offset price

Larger photo of automa dispenser

Company:Shenzhen-kai and electronic instrumentation line market..
Information Name: Used HP8901B modulation analyzer instrument JMM2500 modulation table offset price
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Product Name: modulation analyzer HP8901A / B Brand: HP Product Model: 8901A / B Product Specifications: 150KHz ~ 1300MHz Product Information: Agilent 8910B Modulation Analyzer combines multiple RF functions of the instrument, capable of 150Khzg-1300MHz frequency range The modulated signal is comprehensive, accurate characterization. 8910B can perform precise measurements of modulation, recovery of the modulating signal, determines the RF frequency and RF power measurement. You can count on the 400Hz and 1kHz audio signal and measure the distortion. And can be adjacent channel power measurements or carrier-to-noise ratio measurement (with optional 030-037). 8910B is a fully automated instrument, simply press a button or via GPIB control, will be able to complete all measurements. Transmitter testing 8901B transmitter measurements have completed the required standard features. It can complete transmitter power measurement, frequency counts and accurate measurement of signal modulation, but also to determine the frequency of the demodulated audio signal level and distortion. With Option 030,8910B can quickly and accurately perform adjacent channel power measurement in accordance with CEPT standards. Characterization 8901B RF signal is accurately characterizing RF signal good laboratory and manufacturing equipment. Use 8901B, capable of phase-sensitive device and a web-sensitive device, such as a band-pass filter and a multichannel receiver for precise AM / FM and FM / AM conversion measurements. Excellent isolation between AM and FM so that distinction AM stereo AM and FM, AM and FM FM transmitter component of parasitic AM signal is very simple as well as complex. 8901B automatic measurement system is a major component of automated RF test system. All functions are fully automated and easy to program. Because of the many measuring binding to a single instrument, it can reduce the requirements for instrument interconnection, reducing hardware costs and reduce software development time. Technical indicators 8901B RF input frequency range: 150KHz ~ 1300MHz operating level: 12mVrms ~ 7Vrms input impedance: 50Ω, rating tuning: manual frequency input, automatic or tracking acquisition time (automatic operation): - 1.5% of the maximum safe input level (typical): AC is 35Vrms (for SWR  47dB, typ phase are modulated carrier frequency: 10 ~ 1300MHz rate: 200Hz ~ 20KHz, usually from 20Hz to use to 100KHz, but performance degradation deviation: up to 400 rad The maximum deviation from the resolution: 0.001 radians Accuracy: reading ± 3% ± 1 digital demodulation output distortion: <0.1% THD AM rejection (of the rate of 1KHz 50% AM): <0.03 radian, the maximum deviation (50Hz ~ 3KHz bandwidth) amplitude modulation rate: 20Hz ~ 100KHz modulation: 99% Accuracy: reading ± 2% ± 1 digit, 50Hz ~ 10KHz rate, 150KHz ~ 10MHz of reading ± 1% ± 1 digit, 50Hz ~ 50KHz rate , 10KHz ~ 1300MHz flatness (for constant modulation of the input signal, as indicated by the change of modulation): reading ± 0.3% ± 1 digital demodulation output distortion: <0.3% THD FM inhibition (for at 400Hz and 1KHz rate, 50Hz ~ 3KHz Bandwidth: <0.2% AM remaining AM (50Hz ~ 3KHz Bandwidth): 0.01% rms maximum modulation Resolution: 0.01% Frequency counter range: 150KHz ~ 1300MHz accuracy: a least significant bit of the count ± 3 ± Reference precision internal reference frequency: 10MHz Aging rate: <1 × 10-6 / month (can be used: 1 × 10-9 / day) Maximum resolution: 1Hz RF level (rms) when the frequency range with 11722A: 100KHz ~ 2.6GHz Power range: -20 to + 30dBm radio frequency range between changes in the error: ± 0.02dB / RF range from the reference range of changes in the input VSWR: <1.15 using 11722A sensor module zero (zero adjustment rate numbers): the minimum range of full scale ± 0.5% ± 1 digits (for each large-scale, 10 times smaller) RF power resolution: When W or V mode is 0.1% of full scale, dBm or dB relative way 0.001. Selective power measurements (Option 030 ~ 037) Frequency range: 10MHz ~ 1.3GHz carrier power range: + 30 ~ -20dBm, 12.5,25 and 30KHz filter, + 30 ~ -10dBm, carrier to noise filter dynamic range: 115dB carrier suppression (temperature ≤35 ℃): ≥1 deviation when the channel spacing or 5KHz,> 90dB; the larger of the two relative accuracy: ± 0.5dB, level ≥-95dBc or level ≥-129dBc / Hz power reference Power output: 1.00mW, factory adjusted ± 0.7%, can be traced back to the United States Institute of Standards and Technology Accuracy: 1 year (0 ° ~ 55 ℃) worst case ± 1.2% (± 0.9% rss) audio filter high-pass filter (3dB cutoff frequency): 50Hz and 300Hz low-pass filter (except> 20KHz 3dB filter outside off frequency): 3KHz, 15KHz,> 20KHz de-emphasis filter: 20μs, 50μS, 75μS and 750μs Calibrator ( Standard 8901B) AM modulation calibrator and precision: 33.33% modulation, ratings, internal calibrated to an accuracy of ± 0.1% of the calibrator FM frequency offset and accuracy: 34KHz peak deviation, ratings, internal calibration to ± 0.1 % accuracy 
Contact Detail
Company Name: Shenzhen-kai and electronic instrumentation line market..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Pitt has a new()
Telephone Number: 0755-83794885
Company Address: Shenzhen Zhenhua 163 Golconda electronic market on the first floor room 12847, Futian District, Shenzhen City, Guangdong, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450