TektronixTDS3014B FIG supply TektronixTDS3014B Figure
TektronixTDS3014B FIG supply TektronixTDS3014B Figure
Tektronix TDS3014B Digital Phosphor Oscilloscopes 100MHz | 1.25 GS / s | 4 channels at an affordable price to provide unparalleled performance and portability TDS3000B Series Digital Phosphor Oscilloscopes are extremely popular TDS3000 Series oscilloscopes updated version, which adds many new features and function. All the great features of it include the TDS3000, and improved the speed and connectivity oscilloscope. TDS3000 Series DPO has become a low-cost, high performance and portability of world leaders. To maintain this leadership position, Tektronix TDS3000B series has launched. It improves performance and portability, you'll be able to get more value from TDS3000B series. TDS3000B Series in an economical test equipment, provides all the advantages of Tektronix digital phosphor technology and DPXTM of. DPO technology allows you to view, save, and analyze complex signals, the signal from the three-dimensional information in a comprehensive understanding of the rich colors, intensity gradient waveform image. Now, TDS3000B Series, you can achieve more powerful features, including hardware upgrades, such as faster waveform capture rate (up to 3,600 waveforms / sec Fast Trigger in). It also increases the WaveAlert automatic waveform anomaly detection, e * Scope TM Web-based remote control, high-speed connectivity for integrated Ethernet port and expanded math and measurement capabilities of the new high-level analysis module. Features and Benefits · 100-600MHz Bandwidth · 5GS / s maximum sampling rate Support for Sin (x) / x interpolation · 3600wfms / s continuous waveform capture rate · 2 or 4 channels ? Full VGA color LCD · 25 automatic measurements Features ? Standard equipped with FFT · Multilingual User Interface · QuickMenu graphical user interface, easy to operate · WaveAlertTM automatic waveform anomaly detection · OpenChioceTM solution simplifies instrument control, archiving and analysis -e * ScopeTM online remote control - Built-in Ethernet port -GPIB, RS232, VGA -TDSPCS1 OpenChioce software -WaveStartTM software - can be used with third-party software marine development Beijing OIscope2M oscilloscope software suite dedicated analysis provides integrated · Application Module - Advanced Analysis Module - Limit Testing Module - Telecommunications Mask Testing Module - Extended Video Module -601 serial digital video module ? optional internal battery, can work up to 3 hours * Plug-in printer, in order to prepare the way for portable measurement document · TekProbeTM interface supports active probes, differential probes and current probes, automatic Scaling and Units application of digital design, debug and test of education and training video, installation and service of telecommunications module test power supply design and manufacturing test analysis provides flexible functionality for each application TDS3000 / TDS3000B series through a variety of application modules (optional), you can oscilloscope meet specific application needs. And TDS3000 series supporting the use of application modules have seven kinds, can be installed at any time to meet your testing needs. 1. Telecommunications Mask Testing Application Module --TDS3TMT TDS3TMT with the "User Templates" feature, it can be used to test telecommunications or telecommunications template. If your TDS3000 / B is equipped with TDS3TMT application module, then you can be a standard telecommunications mask testing immediately, using the oscilloscope WaveStar software (WSTROV4.0) You can also create and edit user templates (even non-telecommunications). Supported ITU-TG.703 (DSO, DS1, E1, CIk interfaces, DS2, E2, E3, and DS3 rates) standards. It supports ANSI T1,102 (DS1, DS1A, DS2, DS3 and STS-1 rate) standard. 2. Advanced Analysis Module --TDS3AAM TDS3AAM module TDS3000 / B Series oscilloscopes adds advanced analysis capability. Users can define the waveform through the module for a variety of optional numeric expression, including a variety of mathematical functions and constants and measurement. TDS3AAM module also adds Area and Cycle Area (Area and Cycle Area) measurements, differential and integral function, the average measured value and measurement statistics. In addition, FFT module capability may also TDS3FFT included. FFT module --TDS3FFT FFT 3. harmonic analysis provided for frequency and harmonic analysis when TDS3000 / B Series oscilloscopes installing this module, the instrument can be used as a perfect diagnostic tool, to help complete power supply design and analytical work. By TDS3FFT module, you can check the harmonic power load current. By using the oscilloscope's cursors, you can measure the various frequency components of the frequency and amplitude. The advanced triggering application module can be used as an oscilloscope increase --TDS3TRG logic and pulse triggering advanced triggering capabilities. Logic trigger functions work in troubleshooting digital circuits, logic trigger extremely useful. When the two signals meet a Boolean (Boolean) trigger conditions, trigger the oscilloscope immediately. The module provides two types of logical pattern and state triggering mode. When the signal pulse triggering meet certain timing or threshold condition, pulse triggering can trigger the oscilloscope. The advanced trigger module provides three pulse trigger modes: pulse width, runt pulse and slew rate. 5. Limit Testing Module --TDS3LIM TDS3LIM module can be fast and simple detection circuit is within the set parameters, the need for rapid decision Go / No-Go (if passed) is extremely useful for repetitive testing applications. Users can easily create waveform reference templates to compare with the real-time waveform. Users can also be any number of input channels in any combination of four compared with baseline, and can choose the oscilloscope waveform from the reference limit actions to be taken, such as stop the acquisition, in order to sound warning, print a hard copy or the waveform to disk . 6. Extended video application module --TDS3VID all TDS3000 / B Series oscilloscopes are provided as standard NTSC format, PAL and SECAM (all fields or all lines) triggering. TDS3VID application module adds a lot of dedicated video features, extending this basic video triggering, including the release QuickMenu, Autoset, custom video, HDTV, number of rows and field suppression. TDS3VID also increased the video format line calibration function, vectorscope function and can choose the line video image pattern on the screen. 7.601 Serial Digital Video Module --TDS3SDI this module the TDS3000B Series oscilloscopes converted into a single tool solution. By TDS3SDI module, you can track and identify ITU-R BT.601 video signals, analog component check their representatives and composite video waveforms, bit stream analysis. Features include all the features of TDS3VID, in addition to including the ability to select the line of the video image mode, vectorscope (Pb / Pr) and YPbPr, RGB and YC waveforms on the screen. Requirement 4 through the TDS3000B Series oscilloscopes. Electrical characteristics TDS3000B Series TDS3012B TDS3014B TDS3024B TDS3032B TDS3034B TDS3044B TDS3052B TDS3054B TDS3064B Bandwidth 100MHz 100MHz 300MHz 300MHz 400MHz 400MHz 500MHz 500MHz 600MHz Number of Channels 244,244,244 sampling rate on each channel 1.25GS / s 1.25GS / s 2.5 the GS / s 2.5GS / s 2.5GS / s 5GS / s 5GS / s 5GS / s 5GS / s maximum record length on all models 10K samples vertical resolution for all models 9 Vertical Sensitivity (/ div) on all models 1mV -10V vertical accuracy of ± 2% for all models of the maximum input voltage (1MΩ) on all models 150VRMSCATⅠ (when using the standard 10X probe 300VCATⅡ) All models on position range ± 5 grid BW limit 20MHz 20MHz 20,150MHz 20,150MHz 20,150MHz 20,150MHz 20,150MHz 20,150MHz 20,150MHz the model input coupling AC, DC, GND Input impedance select all 13pF or 50Ω terminals in parallel on all models 1MΩ timebase range 4ns-10s / grid 4ns-10s / grid 4ns-10s / grid 4ns-10s / grid 4ns-10s / grid 4ns-10s / grid 4ns-10s / grid 4ns-10s / grid 1ns-10s / div timebase accuracy shown on the monitor display monitor all models 20ppm color active matrix LCD all models Ordering Information TDS3012B TDS3014B TDS3024B TDS3032B TDS3034B TDS3044B TDS3052B TDS3054B TDS3064B standard accessory probes each two P3010 10X passive probes (TDS3012B); each four P3010 10X passive probes (TDS3014B); each two P6139A 10X passive probes (TDS3032B, TDS3052B) ; each four P6139A 10X passive probes (TDS3024B, TDS3034B, TDS3044B, TDS3054B, TDS3064B). Description: User Manual, Quick Reference Guide and Programmer's Manual. The power cord set before the panel Passport: features easy storage mezzanine owner manual and 3.5-inch floppy disk. NIST traceable calibration certificate. Option TDS3TMT- telecommunications mask testing application module. TDS3AAM- advanced analysis application module. TDS3LIM- limit testing module. TDS3VID- Extended video application module. TDS3SDI- serial digital video module. It requires 4-channel TDS3000B Series oscilloscopes. TDS3GV-GPIB, VGA, RS-232 interfaces and TDSPCS1 OpenChoiceTM communication software. TDSPCS1 OpenChoiceTM communications software - a range of applications, data and communications can be transferred quickly and easily between MS Windows PC and Tektronix oscilloscopes. In a single license package provides, including TDS3GV communication module. Minimum System Requirements: MS Windows98 SE, XP Professional, ME or 2000. MS Office 2000 or XP (applies only to TDS toolbar) -Excel2000 or 2002; Word2000 or 2002. WaveStarTM oscilloscope software -MS Windows98 / ME / 2000 / NT4.0 applications. TDS3BAT- lithium battery, can work continuously for three hours without a power cord circumstances. Fast battery charger TDS3CHG- use. TDS3PRT- plug-in printer, the TDS3000B oscilloscope adds simple random file and print capabilities. OI3000- soft briefcase carrying the instrument to use. Maintenance Manual (TDS3000B Series) - English only (071-0972-00).
Contact Detail
Company Name: | Rip Shenzhen high Electronics Co. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Deng Health(Sales Manager) |
Telephone Number: | 0755-29050100 |
Company Address: | East Central District Longhua Chinese pine and Technology Building all the way 518-520, Shenzhen City, Guangdong, China |
Zip/Postal Code: | 518109 |
Find More Related Products
- Dicing machine prices | Fou..
- Programmable DC Power Suppl..
- Jining KTV Bar soundproofin..
- Zhengzhou to Pugh logistics..
- Kai Yun Feng on OMEGA signa..
- Kai Yun Feng sell ABB module
- PX-XC oxygen barrier pipe w..
- Before qualification online..
- GFCI tester Huayi MS5910
- HNDT-10A ground deflectors ..
- Wet leakage current test sy..
- Supply Shenzhen Electronics..
- HZCableFaultTesterHost
- Sale Daxian GY2671A voltage..
- 7MF1565-3BB00-1AA1
- Wireless high pressure rati..
- LBQ-II leakage protection t..
- GDCT-9500B wireless high pr..
- A limited number LITEPOINTI..
- Model DX8506AGY2675 series ..